NITA Auto Electrician Trade Test study materials
NITA Auto Electrician Trade Test study resources

NITA Auto Electrician Trade Test cheat sheet

NITA Auto Electrician Trade Test · Keep the key ideas within reach.

Quick reference

Electrical Principles and Circuit Fundamentals

  • Ohm's law: V = I × R; power P = V × I = I²R = V²/R. In 12 V systems, a 60 W lamp draws 5 A.

  • Series circuit: same current through all elements, voltages add, total resistance R = R1 + R2 + ...

  • Parallel circuit: same voltage across branches, currents add, 1/R = 1/R1 + 1/R2 + ...; two resistors give R = (R1R2)/(R1+R2).

  • Kirchhoff's current law: sum of currents into a node equals sum leaving; voltage law: sum of drops around a closed loop equals supply EMF.

  • Conductor resistance R = ρL/A: doubling length doubles resistance, doubling cross-section halves it; copper resistivity ≈ 0.0175 Ω·mm²/m at 20 °C.

  • Voltage drop on a cable: Vd = (2 × ρ × L × I)/A for a feed-and-return run; keep total drop under about 0.5 V on 12 V lighting circuits.

  • Capacitor opposition Xc = 1/(2πfC); inductor opposition Xl = 2πfL; in DC steady state a capacitor is open circuit and an inductor is a short.

  • Automotive convention: chassis/body is the return path (negative earth), so a single-wire feed plus local body ground completes the circuit.

Quick reference

Batteries

  • Lead-acid cell nominal EMF is 2.1 V; a 12 V battery has six cells in series, so open-circuit rest voltage is about 12.6–12.8 V at full charge.

  • State of charge by rested open-circuit voltage (25 °C): 12.7 V = 100 %, 12.4 V = 75 %, 12.2 V = 50 %, 12.0 V = 25 %, below 11.8 V = discharged.

  • Specific gravity of electrolyte tracks charge: about 1.265 full, 1.200 half, 1.120 discharged; correct reading by 0.004 per 10 °C from 25 °C.

  • Cold cranking rating is amps delivered at −18 °C for 30 s while holding at least 7.2 V on a 12 V battery; reserve capacity is minutes at 25 A to 10.5 V.

  • Charging voltage limits: gassing begins near 14.4 V at 25 °C; apply temperature compensation of roughly −0.03 V per °C above 25 °C.

  • Capacity falls with discharge rate (Peukert effect); a battery rated 100 Ah at the 20 h rate delivers far less at 5 h rate.

  • Load test rule: apply half the CCA for 15 s; a healthy battery holds above 9.6 V at 20 °C, corrected down about 0.02 V per °C below 20 °C.

  • Safety: charging releases hydrogen (flammable, 4–75 % in air); vent the area, no sparks, and neutralize acid spills with bicarbonate before rinsing.

Quick reference

Charging and Starting Systems

  • Alternator output is three-phase AC rectified by six diodes; a failed diode causes ripple and reduced output, roughly one-third loss per open diode.

  • Regulator target is typically 13.8–14.5 V at 25 °C; below 13.2 V means undercharge, above 15 V risks overcharge and battery damage.

  • Ripple test: AC volts measured at the battery with the engine running should stay under about 0.5 V AC; higher points to diode or stator fault.

  • Lamp/field circuit: the charge warning lamp supplies initial excitation current; if the lamp is open the alternator may not self-excite.

  • Starter current draw: a healthy starter pulls roughly 150–250 A for a small petrol engine; excessive draw with slow cranking suggests a shorted armature or seized bearing.

  • Cranking voltage drop test: measure from battery positive post to starter terminal and battery negative post to engine block while cranking; each should be under 0.5 V.

  • Starter solenoid has pull-in and hold-in windings; a click with no crank often means hold-in open or poor earth, not a flat battery.

  • Belt drive: alternator pulley ratio sets output at idle; a slipping belt gives squeal and low charge at low rpm, resolved by tension or replacement.

Quick reference

Lighting, Signalling and Auxiliary Electrical Systems

  • Headlamp beam aim: dip beam should fall about 1 % below horizontal (roughly 10 cm drop per 10 m) to avoid dazzle.

  • Halogen bulbs must not be touched with bare fingers; skin oils cause hot-spot failure. HID needs high-voltage ballast, typically 85 V start, and must not be tested without rated probes.

  • Bulb power check: a 55 W halogen at 12 V draws about 4.6 A; two lamps on one 10 A fuse is acceptable, three is not.

  • Indicator flash rate is set by the flasher unit; rapid flashing usually means a lamp out on that side, changing load and hence timing.

  • LED retrofits draw far less current; a parallel load resistor or LED-compatible flasher is needed to keep the lamp-failure warning and flash rate correct.

  • Horn and wiper motors are inductive loads; suppression diodes or capacitors across them prevent switch arcing and radio interference.

  • Wiper circuit: park switch keeps the motor powered until the park position, so a motor that stops mid-screen indicates park contact fault.

  • Trailer socket wiring (7-pin): 1 left indicator, 2 fog, 3 earth, 4 right indicator, 5 right tail, 6 brake, 7 left tail.

Quick reference

Ignition Systems and Engine Electrical Management

  • Ignition coil energy E = ½LI²; primary current and dwell time set the spark energy available at the plug.

  • Dwell angle is the crank degrees the primary circuit is closed; too little dwell weakens spark, too much overheats the coil.

  • Spark plug gap and heat range must match the engine; a hotter plug in a high-load engine risks pre-ignition and electrode melting.

  • Coil-on-plug and wasted-spark systems fire in pairs; a misfire on two paired cylinders points to one coil or its driver, not two faults.

  • Knock sensor detects detonation via cylinder block vibration; the ECU retards timing, so a failed sensor usually causes reduced power and poorer economy.

  • Cranking and camshaft sensor signals synchronise injection and ignition; loss of crank signal normally means no start, loss of cam signal means long cranking.

  • Ignition timing is measured in degrees before top dead centre; base timing is checked with the timing connector or service mode enabled.

  • Misfire diagnosis: compare primary current waveform and secondary burn time; a short burn time with high voltage suggests an open plug lead.

Quick reference

Wiring, Harnessing, Connectors and Circuit Protection

  • Fuse rating must be above the circuit's normal load current but at or below the cable's current-carrying capacity; never uprate a fuse to stop it blowing.

  • Metric cable sizes: 0.5, 0.75, 1.0, 1.5, 2.5, 4, 6, 10, 16, 25, 35 mm²; choose by load current plus voltage-drop check, not by fit alone.

  • Automotive wire colour codes use a main colour with a tracer; document any repair and keep colour continuity across a joint.

  • Crimp, do not solder, in high-vibration harness runs; use the correct crimp tool and pull-test each terminal.

  • Heat-shrink and loom tape protect against abrasion; route harnesses away from exhaust and moving parts and secure at intervals under about 300 mm.

  • Relays keep high-current loads off thin switch wiring: terminal 30 supply, 87 output, 86 coil feed, 85 coil earth, 87a normally closed.

  • Circuit protection types: blade fuses for general circuits, maxi fuses for high current, fusible links at the battery feed, and circuit breakers for repeat loads.

  • Earth points must be clean bare metal with star washers; a corroded earth raises resistance and causes dim lamps and erratic ECU behaviour.

Quick reference

Diagnostic Testing, Fault Finding and Measuring Instruments

  • Multimeter use: volts in parallel with the load, amps in series, ohms only on a dead circuit; a meter on amps across a battery will blow its fuse.

  • Voltage-drop testing is more reliable than resistance testing because it is done under load; spec is usually under 0.1 V per connection, 0.5 V total.

  • Continuity test confirms a path but not capacity; a single strand of wire reads 0 Ω yet fails under load.

  • Parasitic drain test: measure current with everything off and modules asleep; typical limit is 30–50 mA. Above that, clamp-meter each fuse circuit.

  • Oscilloscope shows injector and ignition waveforms; look at amplitude, burn time and shape, not just presence of a signal.

  • Fault-finding order: verify the complaint, check obvious and known-good items, then work from supply to load, testing each point under load.

  • Intermittent faults: wiggle-test harnesses and connectors while monitoring the meter; record conditions (temperature, vibration, moisture) that trigger them.

  • Insulation resistance is measured with a megger at a test voltage above the circuit rating; never megger an ECU or connected electronics.

Quick reference

Electronic Control Units, Sensors and Actuators

  • ECU inputs are analogue (temperature, pressure, position) or digital (crank, cam, switch); outputs drive relays, injectors, coils and motors.

  • NTC temperature sensors drop resistance as temperature rises; a common reference pair is about 2.5 kΩ at 20 °C and 300 Ω at 90 °C.

  • Potentiometer throttle and pedal sensors give a voltage ratiometric to a 5 V reference; two-track sensors are compared by the ECU for plausibility.

  • Hall-effect and inductive crank sensors differ: Hall needs a supply and gives a square wave; inductive generates its own AC signal and needs a gap spec.

  • Mass air flow hot-wire sensors output a voltage rising with airflow; contamination causes lean running and poor response.

  • Oxygen sensor output switches 0.1–0.9 V; a lazy sensor or a fixed reading indicates a failed sensor or an air/fuel fault upstream.

  • Actuator tests: injector resistance typically 12–16 Ω; a shorted or open coil sets a driver fault code.

  • ECU adaptation: after replacing a sensor or throttle body, clear codes and perform a relearn or the system may run on default values.

Quick reference

Electrical Machines, Motors and Motor Controls in Vehicles

  • DC series motor (starter) has high starting torque and no load-speed limit; never run a starter motor off-load for long.

  • Permanent-magnet motors are used for wipers, windows and blowers; reversing is done by swapping polarity through a relay pair or a changeover switch.

  • Motor current rises as load torque rises; a stalled motor draws locked-rotor current several times rated and will overheat quickly.

  • Pulse-width modulation controls blower and fan speed; average voltage equals duty cycle × supply, so 50 % duty on 12 V gives about 6 V average.

  • Brushless motors use an electronic commutator and Hall sensors; loss of a sensor phase causes rough running or failure to start.

  • Back-EMF opposes supply and limits motor speed; a motor that runs fast and weak often has worn brushes or a shorted field.

  • Suppression: fit a capacitor or diode across motor terminals to absorb inductive spikes that damage switches and ECUs.

  • Motor control checks: supply at the motor, earth at the motor, then switch/relay operation; a motor that runs with direct 12 V proves the control circuit faulty.

Quick reference

Workshop Safety, Tools, Equipment and Environmental Practice

  • Disconnect the battery negative before working on electrical circuits; wait for airbag systems to discharge per manufacturer time, commonly several minutes.

  • High-voltage (HV) systems on hybrids and EVs use orange cable; only trained personnel with rated gloves and meters may work on them.

  • Battery charging area needs ventilation; hydrogen ignites at 4 % in air, so no flames, grinding or smoking near a gassing battery.

  • Use insulated tools and remove metal jewellery when working near live 12 V feeds; a ring across a battery post causes severe burns.

  • Lifting: use rated stands and chocks, never rely on a jack alone; keep the work area clear of leads and spills.

  • Waste segregation: used oil, coolant, batteries, solvents and refrigerant each have separate disposal streams; refrigerant must be recovered, not vented.

  • Eye and hand protection for battery acid, brake fluid and grinding; acid on skin is flushed with water for at least 15 minutes.

  • Lock-out: tag and isolate equipment before repair, and check test lamps and meters are working before trusting a 'no fault' result.

Quick reference

Technical Drawing, Schematics and Trade Calculations

  • Schematic symbols: battery long line positive, fuse rectangle, relay coil rectangle with contacts, earth the three-line chassis symbol, motor circle with M.

  • Wiring diagram shows physical routing and connector pin numbers; schematic shows electrical function. Use the right one for the question asked.

  • Terminal numbering (DIN): 30 permanent positive, 15 ignition positive, 31 earth, 50 starter control, 61 charge lamp, 85/86 relay coil, 30/87 contacts.

  • Scale reading: a drawing at 1:20 means 1 mm on paper equals 20 mm actual; multiply the measured length by the scale denominator.

  • Cable size calculation: A = (2 × ρ × L × I)/Vd; for 12 V, 4 m run, 10 A, 0.5 V drop, A ≈ (2 × 0.0175 × 4 × 10)/0.5 = 2.8 mm², so use 4 mm².

  • Power and energy: P = VI, energy in watt-hours = watts × hours; a 5 W lamp on for 4 h uses 20 Wh.

  • Resistor colour code: black 0, brown 1, red 2, orange 3, yellow 4, green 5, blue 6, violet 7, grey 8, white 9; gold is 5 % tolerance.

  • Series/parallel reduction: simplify from the far end inward, then apply Ohm's law to find branch currents and voltage drops.