NITA Auto Electrician Trade Test flashcards
NITA Auto Electrician Trade Test · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Ohm's law
- Voltage equals current multiplied by resistance (V = I × R). Rearranged, I = V/R and R = V/I. It applies to any resistive circuit element at constant temperature.
- Power formula
- Electrical power equals voltage times current (P = VI). Substituting Ohm's law gives P = I²R and P = V²/R, used to size fuses and cable.
- Parallel resistance rule
- Reciprocals of branch resistances add to give the reciprocal of total resistance. Two resistors simplify to R1 × R2 divided by R1 + R2.
- Voltage drop calculation
- For a feed-and-return cable run, Vd = 2 × resistivity × length × current divided by cross-section area. Copper resistivity is about 0.0175 ohm square millimetre per metre.
- Battery state of charge
- Rested open-circuit voltage indicates charge: about 12.7 V is full, 12.4 V is 75 percent, 12.2 V is 50 percent and 12.0 V is 25 percent at 25 degrees Celsius.
- Cold cranking amps
- Current a 12 V battery delivers at minus 18 degrees Celsius for 30 seconds while terminal voltage stays at or above 7.2 V. It indicates starting capability in cold weather.
- Electrolyte specific gravity
- Fully charged lead-acid electrolyte reads about 1.265, half charge about 1.200 and discharged about 1.120. Correct the reading by 0.004 per 10 degrees from 25 Celsius.
- Battery load test
- Apply half the rated cold cranking current for 15 seconds. A healthy battery holds above 9.6 V at 20 degrees Celsius, adjusted down about 0.02 V per degree colder.
- Alternator ripple test
- Measure AC volts at the battery with the engine running. Ripple above roughly 0.5 V AC indicates a failed rectifier diode or a stator fault.
- Charging voltage specification
- Regulated alternator output is typically 13.8 to 14.5 V at 25 degrees Celsius. Lower means undercharging; above about 15 V risks overcharging and battery damage.
- Cranking voltage drop test
- While cranking, measure from battery positive to starter terminal and battery negative to engine block. Each reading should stay below about 0.5 V.
- Starter solenoid windings
- The solenoid has pull-in and hold-in windings. A single click with no cranking often means the hold-in winding or its earth is open.
- Headlamp dip aim
- Dipped beam should fall about 1 percent below horizontal, roughly a 10 cm drop over 10 m. This illuminates the road without dazzling oncoming drivers.
- Indicator rapid flash cause
- A flasher unit times the lamps by load. When one indicator lamp fails, current drops and the remaining lamps flash rapidly, signalling the fault.
- Halogen bulb handling
- Never touch the glass with bare fingers. Skin oils create hot spots that crack or shorten the bulb. Hold by the base or use clean gloves.
- Ignition dwell angle
- Crank degrees during which the primary circuit stays closed and coil current builds. Too little weakens the spark; too much overheats the coil.
- Wasted spark ignition
- One coil fires two cylinders at once, one on compression and one on exhaust. A misfire on both paired cylinders points to a shared coil or driver.
- Knock sensor function
- Detects cylinder block vibration from detonation and signals the control unit, which retards ignition timing. A failed sensor usually causes reduced power and poorer economy.
- Fuse selection rule
- The fuse rating must exceed normal circuit current but must not exceed the cable's current capacity. Never fit a larger fuse to stop repeated blowing.
- DIN terminal 30 and 15
- Terminal 30 is permanent battery positive, live with the ignition off. Terminal 15 is ignition-switched positive. Terminal 31 is earth return.
- Four-pin relay terminals
- Terminal 30 is supply, 87 is output to the load, 86 is coil feed and 85 is coil earth. Terminal 87a is the normally closed contact.
- Ammeter connection rule
- An ammeter is connected in series with the circuit because it has very low resistance. Connecting it across a battery causes a short and blows its fuse.
- Parasitic drain limit
- With all loads off and modules asleep, current draw should typically stay below 30 to 50 milliamps. Higher draw is traced by clamping each fuse circuit.
- Continuity test limitation
- A continuity test proves a path exists but not that it carries current. A single remaining wire strand reads near zero ohms yet fails under load.
- NTC temperature sensor
- Resistance falls as temperature rises. Typical values are about 2.5 kilohms at 20 degrees Celsius and 300 ohms at 90 degrees, read as a voltage divider.
- Hall-effect sensor output
- Requires a supply and produces a square-wave digital signal as the target passes. Used for crank, cam and wheel speed sensing where a clean pulse is needed.
- Oxygen sensor voltage range
- A narrow-band sensor switches between about 0.1 V lean and 0.9 V rich. A lazy or fixed reading indicates a failed sensor or an air-fuel fault upstream.
- Pulse-width modulation
- Switching a supply on and off rapidly controls average voltage. Average voltage equals duty cycle times supply, so 50 percent duty on 12 V gives about 6 V.
- Locked-rotor current
- A stalled motor draws several times its rated current because back-EMF disappears. It overheats quickly and can damage wiring or blow the protection fuse.
- Motor suppression capacitor
- Fitted across motor or inductive load terminals to absorb voltage spikes when the circuit opens. It protects switches, relays and sensitive control units from arcing damage.
- High-voltage cable identification
- Orange cable marks high-voltage circuits on hybrid and electric vehicles. Only trained personnel using rated gloves, tools and meters may work on them.
- Cable size calculation
- Cross-section area equals 2 times resistivity times length times current, divided by permitted voltage drop. Choose the next standard metric size above the result.