Craftsman Electricity key terms
Craftsman Electricity · Get comfortable with the vocabulary.
- Working clearance
- Related: Arc flash boundary, Lockout/tagout
The unobstructed floor space and headroom that must be kept in front of electrical equipment so a person can work on it safely without contacting live parts or blocking an escape path.
- Arc flash boundary
- Related: Working clearance, Available fault current
The distance from exposed live parts within which a person could receive a second-degree burn from an arc flash; it depends on available fault current and clearing time.
- Lockout/tagout
- Related: Working clearance, Voltage tester
A procedure for de-energizing equipment, applying a personal lock and tag, and verifying the absence of voltage so the equipment cannot be re-energized while someone works on it.
- Approved
- Related: Authority having jurisdiction, Listed
A product or method that is acceptable to the authority having jurisdiction, typically because it is listed by a recognized testing laboratory or meets an adopted standard.
- Authority having jurisdiction
- Related: Approved, Listed
The organization or individual responsible for enforcing the electrical code and approving equipment, installations, and materials within a jurisdiction, such as a local electrical inspector.
- Listed
- Related: Approved, Authority having jurisdiction
Equipment that appears in a published list maintained by a nationally recognized testing laboratory and is marked to show it has been evaluated to a specific safety standard.
- Ohm's law
- Related: Series circuit, Parallel circuit
The relationship among voltage, current, and resistance in a circuit: voltage equals current multiplied by resistance, and current equals voltage divided by resistance.
- Power factor
- Related: Apparent power, Inductive load
The ratio of real power in watts to apparent power in volt-amperes in an alternating-current circuit; a value below one means some current does no useful work.
- Apparent power
- Related: Power factor, Inductive load
The product of root-mean-square voltage and root-mean-square current in a circuit, expressed in volt-amperes, and the value used to size conductors and equipment.
- Inductive load
- Related: Power factor, Inrush current
A load in which current lags voltage because of a magnetic field, such as a motor winding or transformer coil, causing a lagging power factor and additional reactive current.
- Series circuit
- Related: Parallel circuit, Ohm's law
A circuit with only one path for current, so the same current flows through every component and the total resistance is the sum of the individual resistances.
- Parallel circuit
- Related: Series circuit, Ohm's law
A circuit in which components are connected across the same two points, so each branch sees the same voltage and the total current is the sum of branch currents.
- Ampacity
- Related: Ambient temperature correction, Conductor bundling adjustment
The maximum current, in amperes, that a conductor can carry continuously under the conditions of use without exceeding its temperature rating and damaging its insulation.
- Ambient temperature correction
- Related: Ampacity, Conductor bundling adjustment
A multiplier applied to a conductor's ampacity when the surrounding air or earth is hotter than the temperature on which the tabulated value is based, because heat shortens insulation life.
- Conductor bundling adjustment
- Related: Ampacity, Ambient temperature correction
A reduction factor applied when several current-carrying conductors share a raceway or cable, because their combined heat cannot dissipate as readily as a single conductor's.
- Box fill
- Related: Raceway fill, Junction box
The required minimum volume of an outlet, junction, or device box based on the number and size of conductors, devices, clamps, and equipment grounds it contains.
- Raceway fill
- Related: Box fill, Conductor bundling adjustment
The limit on how much of a conduit's cross-sectional area may be occupied by conductors, set so wires can be pulled without damage and heat can dissipate.
- Continuous load
- Related: Demand factor, Feeder
A load expected to operate at maximum current for three hours or more, which must be sized at no less than 125 percent of its current when calculating branch circuits and feeders.
- Demand factor
- Related: Connected load, Feeder
The ratio of the maximum demand on a system to the total connected load, used to size service and feeder capacity because not all loads operate at once.
- Connected load
- Related: Demand factor, Continuous load
The sum of the nameplate ratings of all equipment connected to a system, before any demand factors or diversity allowances are applied.
- Feeder
- Related: Branch circuit, Service conductor
All circuit conductors between the service equipment, source of a separately derived system, or output of a power supply, and the final branch-circuit overcurrent device.
- Branch circuit
- Related: Feeder, Continuous load
The circuit conductors between the final overcurrent device protecting the circuit and the outlet or outlets it serves, such as receptacles or luminaires.
- Service conductor
- Related: Feeder, Demand factor
The conductors that carry power from the utility's service point to the service equipment disconnect, sized for the calculated load and often subject to utility or code rules.
- Equipment grounding conductor
- Related: Bonding jumper, Ground-fault circuit interrupter
The conductive path that connects normally non-current-carrying metal parts of equipment to the system grounding point, providing a low-impedance fault path that trips the overcurrent device.
- Bonding jumper
- Related: Equipment grounding conductor, Grounding electrode conductor
A conductor that ensures electrical continuity between metal parts that must be connected, such as service equipment enclosures, metal raceways, or water piping.
- Grounding electrode conductor
- Related: Bonding jumper, Equipment grounding conductor
The conductor that connects the grounded conductor or equipment grounding conductor to the grounding electrode system, such as a ground rod or metal water pipe.
- Ground-fault circuit interrupter
- Related: Equipment grounding conductor, Overcurrent protective device
A device that de-energizes a circuit within a set time when it senses a small current imbalance between the ungrounded and grounded conductors, indicating current is leaking to ground.
- Overcurrent protective device
- Related: Ground-fault circuit interrupter, Available fault current
A fuse or circuit breaker that opens a circuit automatically when current exceeds its rating for a set time, protecting conductors and equipment from overheating.
- Available fault current
- Related: Overcurrent protective device, Arc flash boundary
The maximum current that would flow at a given point in a system during a short circuit or ground fault, used to select equipment with adequate interrupting rating.
- Motor full-load current
- Related: Motor overload protection, Inrush current
The current a motor draws at rated load and rated voltage, taken from code tables for conductor and overload sizing rather than from the motor nameplate.
- Motor overload protection
- Related: Motor full-load current, Overcurrent protective device
A device, such as a thermal overload relay, that protects the motor from sustained excess current due to mechanical overload or phase loss, separate from short-circuit protection.
- Inrush current
- Related: Motor full-load current, Inductive load
The brief, high current a motor or transformer draws when first energized, before its magnetic field is established, which short-circuit protection must tolerate without nuisance tripping.
- Across-the-line starter
- Related: Motor overload protection, Inrush current
A motor control assembly that connects the motor directly to the supply through contactors and overload relays, providing full voltage at starting and simple forward operation.
- Transformer turns ratio
- Related: Transformer kVA rating, Delta-wye connection
The ratio of primary to secondary winding turns, which determines the ratio of primary to secondary voltage and inversely relates the currents in the two windings.
- Transformer kVA rating
- Related: Transformer turns ratio, Apparent power
The apparent power a transformer can deliver continuously without exceeding its temperature rise, used with voltage to calculate rated primary and secondary current.
- Delta-wye connection
- Related: Transformer turns ratio, Transformer kVA rating
A transformer connection with a delta primary and a wye secondary, which provides a neutral for line-to-neutral loads and shifts secondary voltage by 30 degrees from the primary.
- Voltage tester
- Related: Lockout/tagout, Megohmmeter
An instrument used to confirm the presence or absence of voltage on a conductor or terminal before work begins, and to verify the tester on a known live source first.
- Megohmmeter
- Related: Voltage tester, Motor overload protection
An instrument that applies a high direct voltage to insulation and measures resistance, used to detect moisture, contamination, or deterioration in windings and cables.
- Clamp-on ammeter
- Related: Voltage tester, Motor full-load current
A meter whose jaws encircle a single conductor and measure current by sensing its magnetic field, allowing load readings without breaking the circuit.