Craftsman Electricity study plan
Craftsman Electricity · Give each week a clear focus.
8 weeks · About 7 hours per week
Electrical Safety and Codes & Grounding, Bonding, and Overcurrent Protection
Explain the scope and layout of the NEC article structure well enough to locate any rule for a wiring method, grounding, or overcurrent device within two minutes
Define the terms qualified person, approved, listed, and labeled, and distinguish them from each other in writing
Identify the working-space, dedicated-equipment-space, and illumination requirements around electrical equipment and state the dimensions from memory
Describe the hierarchy of protective grounding and bonding so that you can explain why the equipment grounding conductor and the main bonding jumper serve different purposes
Apply the basic rules for arc-fault and ground-fault circuit-interrupter protection to a set of dwelling and commercial scenarios
Your checkpoint
A one-page handwritten reference sheet listing clearance dimensions, GFCI/AFCI locations, and the grounding-versus-bonding distinction, scored against the code text with no more than two errors
Electrical Safety and Codes & Grounding, Bonding, and Overcurrent Protection
Size an overcurrent device and conductor for a given continuous and noncontinuous load using the standard and next-size-up rules
Select the correct type and rating of overcurrent protective device for motor, HVAC, and general-purpose circuits and justify each choice
Trace the required path of the grounding electrode system and list which electrodes must be bonded together
Calculate the minimum size of the equipment grounding conductor and the supply-side bonding jumper for a given service
Interpret the rules for interrupting rating, series ratings, and current limitation as they apply to a panel schedule
Your checkpoint
A completed panel schedule for a small commercial service showing device ratings, conductor sizes, and grounding conductor sizes, with each value annotated by the rule used
Electrical Theory and Principles & Branch Circuits, Feeders, and Service Calculations
Solve series, parallel, and combination circuit problems for resistance, current, voltage drop, and power without reference notes
Convert between single-phase and three-phase quantities using the square root of three relationship and verify results by an independent method
Compute demand loads for a dwelling using the general lighting, small-appliance, laundry, and appliance provisions
Calculate a feeder and service size for a multifamily or small commercial occupancy including the demand factors
Explain how power factor and continuous-load multipliers change the ampacity a conductor must carry
Your checkpoint
A worked service calculation for a single-family dwelling with a load summary table and a final service size, checked against the code demand factors with all arithmetic shown
Wiring Methods and Materials & Branch Circuits, Feeders, and Service Calculations
Match each wiring method to the occupancies and conditions where it is permitted and prohibited
Size and select conductors using ampacity tables with the temperature-correction and adjustment factors applied correctly
Determine box fill, conductor bending space, and pull-box sizing for a given raceway layout
Lay out a feeder route through a building identifying support, protection, and expansion requirements
Distinguish the requirements for wet, damp, and dry locations and for hazardous classified locations at a summary level
Your checkpoint
A dimensioned raceway and box layout for one floor of a small building, with conductor sizes, box fill calculations, and support spacing all shown and defensible
Branch Circuits, Feeders, and Service Calculations & Wiring Methods and Materials
Compute branch-circuit requirements for kitchen, bathroom, laundry, and garage receptacles in a dwelling
Size multiwire branch circuits and verify the disconnect and handle-tie requirements
Apply the rules for receptacle spacing, countertop circuits, and required lighting outlets in dwelling units
Select the correct wiring method and conductor type for a feeder passing through a corrosive or wet environment
Calculate voltage drop on a long feeder and state at least two remedies when the drop exceeds the recommended value
Your checkpoint
A complete branch-circuit plan for one dwelling floor showing every circuit, its rating, conductor size, and connected load, with a voltage-drop check on the two longest runs
Motors, Controls, and HVAC Equipment
Size branch-circuit conductors, short-circuit protection, and overload protection for a motor from nameplate data using the tables
Determine full-load current, locked-rotor current, and the disconnect rating for a given motor installation
Explain the difference between overload and short-circuit protection and where each device belongs in a motor circuit
Describe the control-circuit requirements for a magnetic starter with start-stop and interlock functions
Identify the disconnect, working-space, and nameplate requirements specific to HVAC equipment and hermetic refrigerant motor-compressors
Your checkpoint
A motor and HVAC equipment schedule for one mechanical room listing each unit's full-load current, conductor size, branch protection, overload setting, and disconnect rating with the table references noted
Transformers and Power Distribution
Calculate primary and secondary full-load currents for single-phase and three-phase transformers
Size the primary and secondary overcurrent protection and the transformer feeder conductors for a given transformer
Apply the rules for transformer grounding, bonding, and the separation of primary and secondary conductors
Explain the requirements for dry-type transformer installation, ventilation, and accessibility
Describe the characteristics of common distribution systems, including the grounded and ungrounded configurations and where each is used
Your checkpoint
A transformer installation package for one 75 kVA three-phase unit showing primary and secondary currents, protection sizes, conductor sizes, and grounding connections, with each choice justified
Electrical Maintenance and Troubleshooting & Electrical Safety and Codes & Grounding, Bonding, and Overcurrent Protection
Diagnose at least six fault scenarios from measured voltage and resistance readings and state the likely cause of each
Describe a safe lockout/tagout sequence and the personal protective equipment selection process for common tasks
Demonstrate a systematic troubleshooting method for an open neutral, a ground fault, and a high-resistance connection
Review your weakest domain from earlier weeks and close the gap with targeted practice
Complete a timed mixed-domain practice set and analyze every missed question for its underlying rule
Your checkpoint
A troubleshooting log of six resolved fault scenarios with the meter readings, the reasoning chain, and the code rule that governs the repair, plus a one-page list of the ten rules you most often missed
Milestones
Week 2: Without notes, size the overcurrent device and grounding conductor for three mixed scenarios and score at least 80 percent correct
Week 4: Complete a timed 40-question set drawn from domains 1, 2, 4, and 5 and score at least 75 percent, with every miss traced to a specific rule
Week 6: Produce the full motor and HVAC schedule unaided and have it checked against the code tables with no more than one sizing error
Week 8: Complete a full-length timed mixed-domain practice exam and score at least 80 percent overall with no single domain below 70 percent