Question 1Radiation Physics and Equipment

In a diagnostic X-ray tube, what is the primary role of the rotating anode?

  1. To accelerate electrons toward the cathode
  2. To filter low-energy photons from the beam
  3. To spread the electron beam over a larger focal track so heat is dissipated Correct answer.
  4. To rectify the high-voltage supply

Explanation

The rotating anode spins a disc so the electron beam strikes a moving focal track rather than one fixed spot, which distributes thermal load over a larger area and raises tube output limits. The actual focal spot stays small for image sharpness while the effective area for heat is large.

Question 2Radiation Physics and Equipment

A radiographer selects a higher kVp for a given exposure. What is the main effect on the emitted X-ray spectrum?

  1. The maximum photon energy decreases
  2. The characteristic peaks shift to lower energies
  3. The beam becomes more penetrating with a higher average energy Correct answer.
  4. The number of photons always falls to zero

Explanation

Increasing kVp raises the peak photon energy and shifts the bremsstrahlung spectrum toward higher energies, so the beam has greater penetrability and a higher average energy. The characteristic peaks stay at fixed energies because they depend on the anode material.

Question 3Radiation Physics and Equipment

Which interaction predominates for X-ray photons in the 30-90 keV range with soft tissue and produces scatter that degrades image contrast?

  1. Photoelectric absorption
  2. Compton scattering Correct answer.
  3. Pair production
  4. Coherent Rayleigh scattering

Explanation

Compton scattering dominates in soft tissue at diagnostic energies above roughly 30 keV and deflects photons, producing scatter that reduces contrast. Photoelectric absorption dominates at lower energies and in high-atomic-number materials such as bone.

Question 4Radiation Physics and Equipment

What is the purpose of adding aluminium filtration to the X-ray beam?

  1. To remove low-energy photons that would only add patient dose Correct answer.
  2. To reduce the anode heel effect
  3. To increase the characteristic radiation peaks
  4. To increase the maximum photon energy

Explanation

Added filtration preferentially absorbs low-energy photons that would be absorbed in the patient without contributing to the image, thereby reducing skin dose and hardening the beam. It does not change the peak energy set by kVp.

Question 5Radiation Physics and Equipment

A radiographer increases the SID from 100 cm to 200 cm without changing other factors. What happens to the beam intensity at the image receptor, ignoring attenuation?

  1. It falls to one quarter Correct answer.
  2. It stays unchanged
  3. It is doubled
  4. It is halved

Explanation

The inverse square law states that intensity is inversely proportional to the square of the distance, so doubling the distance reduces intensity by a factor of four. In practice exposure factors must be adjusted to compensate.

Question 6Radiation Physics and Equipment

Which component of the X-ray circuit converts alternating current into the high direct voltage applied across the tube?

  1. Filament transformer
  2. Timer circuit
  3. Autotransformer
  4. High-voltage transformer and rectifier bank Correct answer.

Explanation

The step-up high-voltage transformer raises the voltage and the rectifier bank converts alternating current to the unidirectional high voltage needed for X-ray production. The autotransformer only provides coarse kVp selection at low voltage.

Question 7Radiation Physics and Equipment

What is the practical effect of using a small focal spot compared with a large focal spot at the same exposure?

  1. Poorer spatial resolution but higher heat capacity
  2. No change in resolution but higher tube current allowed
  3. Better spatial resolution but lower heat capacity Correct answer.
  4. Reduced patient dose with no resolution change

Explanation

A smaller focal spot reduces geometric unsharpness and improves spatial resolution, but concentrates heat on a smaller anode area, lowering the maximum exposure that can be used. Focal spot choice is therefore a trade-off between sharpness and tube loading.

Question 8Radiation Physics and Equipment

The anode heel effect causes which pattern of beam intensity across the exposure field?

  1. Higher intensity at the field edges than the center
  2. Higher intensity toward the anode side
  3. Uniform intensity across the field
  4. Higher intensity toward the cathode side Correct answer.

Explanation

X-rays produced deeper in the anode are attenuated more within the anode material, so the beam is less intense on the anode side and more intense toward the cathode side. The thicker part of the patient is normally placed toward the cathode side to use the higher intensity.

Question 9Radiation Physics and Equipment

Which factor primarily determines the quantity of X-rays produced in an exposure when kVp is held constant?

  1. Focal spot size
  2. mAs Correct answer.
  3. Anode angle
  4. Source-to-image distance

Explanation

With kVp fixed, the tube current multiplied by exposure time (mAs) determines the number of electrons hitting the anode and therefore the number of X-ray photons produced. Focal spot, distance, and anode angle affect distribution or geometry rather than primary beam quantity.

Question 10Radiation Physics and Equipment

A radiographer increases kVp from 60 to 80 while halving mAs. What is the expected effect on patient dose and image contrast?

  1. Lower dose with reduced contrast Correct answer.
  2. Higher dose with unchanged contrast
  3. Higher dose and higher contrast
  4. Lower dose with increased contrast

Explanation

Higher kVp with reduced mAs is the basis of the 15 percent rule: the beam is more penetrating so less mAs is needed, reducing dose, but the increased scatter and reduced differential absorption lower subject contrast. Image contrast therefore decreases.

Question 11Radiation Physics and Equipment

Which statement correctly describes the relationship between tube current and filament temperature?

  1. Higher filament temperature decreases thermionic emission
  2. Tube current is controlled by the anode rotation speed
  3. Higher filament temperature increases thermionic emission and tube current Correct answer.
  4. Tube current is independent of filament temperature

Explanation

Increasing filament current raises filament temperature, increasing thermionic emission of electrons and therefore tube current for a given tube voltage. This is the mechanism by which mAs selection controls beam quantity.

Question 12Radiation Physics and Equipment

Which detector type converts absorbed X-ray energy directly into an electrical signal without a separate light-conversion stage?

  1. Direct-conversion flat-panel detector Correct answer.
  2. X-ray image intensifier
  3. Photostimulable phosphor plate
  4. Indirect-conversion flat-panel detector

Explanation

Direct-conversion flat-panel detectors use a photoconductor such as amorphous selenium that converts X-ray energy directly into charge, avoiding a scintillation light stage. Indirect detectors use a scintillator to produce light that is then converted to charge.

Question 13Radiation Physics and Equipment

What does the modulation transfer function (MTF) describe for an imaging system?

  1. The ability of the system to transfer spatial frequency information from object to image Correct answer.
  2. The heat capacity of the anode
  3. The energy spectrum of the X-ray beam
  4. The total radiation dose delivered to the detector

Explanation

MTF quantifies how well an imaging system preserves contrast at different spatial frequencies, with values falling at higher frequencies as resolution is lost. It is a standard measure of spatial resolution performance.

Question 14Radiation Physics and Equipment

Which change will most reduce motion unsharpness in a radiograph of an uncooperative patient?

  1. Decreasing the source-to-image distance
  2. Increasing the object-to-image receptor distance
  3. Increasing exposure time
  4. Using a shorter exposure time Correct answer.

Explanation

Motion blur depends on how far the object moves during the exposure, so shortening exposure time reduces it. Reducing object-to-image receptor distance and increasing SID also reduce geometric unsharpness but do not address patient movement.

Question 15Radiation Physics and Equipment

What is the function of a grid in radiography?

  1. To absorb scattered radiation before it reaches the receptor Correct answer.
  2. To increase beam intensity at the receptor
  3. To filter characteristic radiation
  4. To reduce the anode heel effect

Explanation

A grid consists of radiopaque strips that absorb photons not travelling along the primary beam direction, reducing scatter and improving contrast. The cost is increased patient dose because higher mAs is required.

Question 16Radiation Physics and Equipment

A radiographer changes from a 12:1 grid to a 6:1 grid at the same kVp. What is the expected effect on required mAs and contrast?

  1. Higher mAs required and lower contrast
  2. Higher mAs required and higher contrast
  3. Lower mAs required and lower contrast Correct answer.
  4. Lower mAs required and higher contrast

Explanation

A lower grid ratio removes less scatter, so less mAs is needed to maintain receptor exposure but contrast is reduced because more scatter reaches the receptor. Higher grid ratios improve contrast at the cost of higher dose.

Question 17Radiation Physics and Equipment

Which quantity describes the number of photons per unit area and is affected by mAs and distance?

  1. Beam quality
  2. Half-value layer
  3. Peak kilovoltage
  4. Beam quantity Correct answer.

Explanation

Beam quantity refers to the number of photons and is controlled by mAs and modified by distance through the inverse square law. Beam quality refers to penetrability and is controlled mainly by kVp and filtration.

Question 18Radiation Physics and Equipment

What is the main reason for using collimation in radiography?

  1. To increase the field size for better visualization
  2. To increase the effective photon energy
  3. To correct the anode heel effect
  4. To reduce patient dose and scatter by limiting the irradiated field Correct answer.

Explanation

Collimation restricts the X-ray field to the region of interest, reducing the volume of tissue irradiated and the amount of scatter generated. This lowers patient dose and improves image contrast.

Question 19Radiation Physics and Equipment

In a photostimulable phosphor computed radiography system, what happens when the imaging plate is scanned by the laser?

  1. The plate is erased completely
  2. The plate emits X-rays again
  3. The plate is heated to melt the phosphor
  4. Stored energy is released as light proportional to absorbed X-rays Correct answer.

Explanation

The laser stimulates trapped electrons in the phosphor to release stored energy as luminescence, which is detected and converted into a digital signal. After readout the plate is exposed to bright light to erase residual signal.

Question 20Radiation Physics and Equipment

A radiographer must image a thick body part while keeping receptor dose reasonable. Which combination is most appropriate?

  1. Low kVp with high mAs
  2. High kVp with high mAs and no filtration
  3. Low kVp with low mAs
  4. High kVp with lower mAs and appropriate filtration Correct answer.

Explanation

For thick parts, higher kVp increases penetrability so lower mAs can be used, reducing dose while maintaining adequate receptor exposure, provided filtration is adequate to remove low-energy photons. Low kVp with high mAs would increase dose without improving penetration.

Question 21Radiation Physics and Equipment

Which statement correctly describes the relationship between the effective focal spot and the actual focal spot?

  1. The effective focal spot depends only on the filament size
  2. They are always equal regardless of anode angle
  3. The effective focal spot is always larger than the actual focal spot
  4. The effective focal spot is smaller than the actual focal spot due to the anode angle Correct answer.

Explanation

The anode is angled so the projected focal spot seen from the image receptor is foreshortened and smaller than the actual focal spot on the anode. This improves resolution while keeping a larger area for heat dissipation.

Question 22Radiation Physics and Equipment

What is the main function of the high-frequency generator in modern X-ray equipment?

  1. To eliminate the need for filtration
  2. To increase the focal spot size
  3. To reduce the anode rotation speed
  4. To produce a nearly constant high voltage with low ripple Correct answer.

Explanation

High-frequency generators convert the supply to a high-frequency waveform before stepping up the voltage, producing a nearly constant potential with low ripple. This improves output efficiency and reduces patient dose compared with single-phase systems.

Question 23Radiation Physics and Equipment

A radiographer observes that a digital image has adequate brightness but poor contrast and a large amount of scatter. Which factor is most likely responsible?

  1. Too small a focal spot
  2. Insufficient collimation and a large irradiated field Correct answer.
  3. Too high a spatial frequency
  4. Excessive grid ratio

Explanation

Large field size increases the volume of tissue irradiated and the amount of scatter reaching the receptor, reducing contrast. Proper collimation limits scatter and improves contrast without changing receptor brightness.

Question 24Radiation Physics and Equipment

Which statement best describes the purpose of automatic exposure control (AEC) in radiography?

  1. To terminate the exposure when a preset receptor dose is reached Correct answer.
  2. To control the focal spot size automatically
  3. To reduce the anode heel effect
  4. To automatically increase kVp for thick patients

Explanation

AEC uses ionization chambers or solid-state detectors to monitor radiation reaching the receptor and terminates the exposure at a preset level, improving consistency and reducing repeat exposures. It does not automatically select kVp or alter focal spot geometry.

Question 25Radiographic Anatomy and Physiology

On a PA chest radiograph, which structure forms the upper right border of the mediastinal silhouette in a normal adult?

  1. The ascending aorta
  2. The superior vena cava Correct answer.
  3. The right atrium
  4. The right ventricle

Explanation

The right cardiomediastinal border on a PA chest image is formed above by the superior vena cava and below by the right atrium. The superior vena cava is the dominant upper right border structure. The right ventricle is an anterior chamber and does not create the right border.

Question 26Radiographic Anatomy and Physiology

A radiograph of the lumbar spine shows the pedicles as oval densities with the spinous process projecting centrally and the vertebral body seen without significant rotation. Which projection was most likely performed?

  1. AP lumbar spine Correct answer.
  2. Swimmer's view
  3. Lateral lumbar spine
  4. Oblique lumbar spine

Explanation

On an AP lumbar projection the vertebral bodies are seen en face, pedicles appear as oval densities on each side, and the spinous process is central. A lateral projection would show the vertebral bodies and disc spaces in profile. Oblique projections are used to demonstrate the pars interarticularis, and a swimmer's view targets the cervicothoracic junction.

Question 27Radiographic Anatomy and Physiology

Which carpal bone is most commonly fractured, particularly after a fall on an outstretched hand?

  1. Pisiform
  2. Trapezium
  3. Lunate
  4. Scaphoid Correct answer.

Explanation

The scaphoid is the most frequently fractured carpal bone, typically after a fall onto an outstretched hand. Its retrograde blood supply from the dorsal branch of the radial artery explains the risk of avascular necrosis. The lunate, pisiform, and trapezium are fractured far less often.

Question 28Radiographic Anatomy and Physiology

During an intravenous urogram, the renal collecting system and ureters are best demonstrated at which time after contrast injection?

  1. At 5 to 10 minutes
  2. Immediately at 1 minute
  3. At 15 to 20 minutes Correct answer.
  4. At 45 to 60 minutes

Explanation

The nephrogram phase occurs early after injection, while the collecting system and ureters fill with contrast at approximately 15 to 20 minutes. Delayed images at 45 to 60 minutes are used when obstruction or poor function is suspected. Immediate imaging captures the vascular and nephrogram phases rather than the collecting system.

Question 29Radiographic Anatomy and Physiology

Which skull suture separates the frontal bone from the parietal bones?

  1. Squamosal suture
  2. Sagittal suture
  3. Lambdoid suture
  4. Coronal suture Correct answer.

Explanation

The coronal suture runs transversely across the skull and separates the frontal bone from the two parietal bones. The sagittal suture separates the parietal bones from each other, and the lambdoid suture separates the parietals from the occipital bone. The squamosal suture lies between the temporal and parietal bones.

Question 30Radiographic Anatomy and Physiology

On a lateral chest radiograph, the left hemidiaphragm can usually be identified because it is:

  1. Obscured by the cardiac silhouette
  2. Marked by the azygos fissure
  3. Higher than the right hemidiaphragm
  4. Lower than the right hemidiaphragm Correct answer.

Explanation

The left hemidiaphragm normally lies lower than the right because the liver elevates the right hemidiaphragm. The gastric bubble is often visible beneath the left hemidiaphragm as an additional landmark. The cardiac silhouette overlaps the left hemidiaphragm anteriorly but does not reliably identify it.

Question 31Radiographic Anatomy and Physiology

Which anatomic structure is demonstrated in profile on a true lateral projection of the cervical spine?

  1. The facet joints Correct answer.
  2. The pedicles en face
  3. The spinous process en face
  4. The intervertebral foramina

Explanation

On a true lateral cervical spine image the facet joints are seen in profile, allowing assessment of alignment. The intervertebral foramina are demonstrated on oblique projections, and the pedicles appear en face on AP images. The spinous process is seen in profile on lateral views, not en face.

Question 32Radiographic Anatomy and Physiology

Which of the following structures is located in the right lower quadrant of the abdomen?

  1. The left kidney
  2. The caecum Correct answer.
  3. The spleen
  4. The stomach

Explanation

The caecum lies in the right iliac fossa, the start of the large intestine, and is a right lower quadrant structure. The spleen occupies the left upper quadrant, the stomach lies in the left upper quadrant, and the left kidney is in the left upper quadrant.

Question 33Radiographic Anatomy and Physiology

A patient is positioned for an AP projection of the knee. Which structure is seen superimposed over the distal femur?

  1. The tibial tuberosity
  2. The medial malleolus
  3. The patella Correct answer.
  4. The fibular head

Explanation

On an AP knee projection the patella is superimposed over the distal femur. The fibular head is seen laterally, and the tibial tuberosity is seen in profile on a lateral projection. The medial malleolus belongs to the ankle and is not part of a knee image.

Question 34Radiographic Anatomy and Physiology

Which structure passes through the foramen magnum?

  1. The spinal cord Correct answer.
  2. The internal carotid artery
  3. The facial nerve
  4. The optic nerve

Explanation

The foramen magnum is the large opening in the occipital bone through which the medulla oblongata and spinal cord pass. The internal carotid artery enters the skull through the carotid canal, the optic nerve passes through the optic canal, and the facial nerve exits through the internal acoustic meatus.

Question 35Radiographic Anatomy and Physiology

Which projection of the shoulder best demonstrates the greater tuberosity in profile?

  1. AP shoulder in external rotation Correct answer.
  2. Axillary projection
  3. Grashey projection
  4. AP shoulder in internal rotation

Explanation

External rotation of the shoulder on an AP projection places the greater tuberosity in profile laterally. Internal rotation profiles the lesser tuberosity, and the axillary projection demonstrates the glenohumeral joint and acromion. The Grashey projection is used to show the glenohumeral joint space.

Question 36Radiographic Anatomy and Physiology

Which chamber of the heart forms the apex of the cardiac silhouette on a frontal chest radiograph?

  1. The right atrium
  2. The right ventricle
  3. The left atrium
  4. The left ventricle Correct answer.

Explanation

The left ventricle forms the apex of the cardiac silhouette, directed toward the left costophrenic region. The right ventricle lies anteriorly and forms much of the anterior cardiac border, while the left atrium forms part of the posterior border. The right atrium forms the lower right border.

Question 37Radiographic Anatomy and Physiology

A radiograph of the pelvis shows the iliac wings, sacrum, and femoral heads. Which structure is seen as a ring-like density in the lower pelvis?

  1. The obturator foramen Correct answer.
  2. The sacroiliac joint
  3. The acetabulum
  4. The pubic symphysis

Explanation

The obturator foramen appears as a large ring-like or oval radiolucent opening bounded by the pubis and ischium in the lower pelvis. The acetabulum is the cup-shaped socket receiving the femoral head, and the sacroiliac joints are located posteriorly. The pubic symphysis is the midline joint between the pubic bones.

Question 38Radiographic Anatomy and Physiology

Which sinus is most often underdeveloped or absent in adults and may be mistaken for pathology on a skull radiograph?

  1. The maxillary sinus
  2. The ethmoid sinus
  3. The sphenoid sinus
  4. The frontal sinus Correct answer.

Explanation

The frontal sinus is variable in size and may be underdeveloped or absent, which can be mistaken for disease if not recognized as a normal variant. The maxillary sinuses are the largest paranasal sinuses and are consistently present. Ethmoid and sphenoid sinuses are also consistently present but vary in size.

Question 39Radiographic Anatomy and Physiology

During a barium swallow, which structure is assessed for the presence of a posterior impression on the oesophagus?

  1. The trachea
  2. The left atrium
  3. The thyroid gland
  4. The aortic arch Correct answer.

Explanation

The aortic arch produces a normal posterior impression on the oesophagus, visible during a barium swallow. The left atrium can produce an impression anteriorly in the region of the heart, while the thyroid and trachea do not typically create a posterior impression. Recognizing these normal impressions prevents misinterpretation as stricture.

Question 40Radiographic Anatomy and Physiology

Which of the following best explains why the right main bronchus is more likely to aspirate a foreign body than the left?

  1. The right main bronchus is narrower and more horizontal
  2. The left main bronchus is wider and more vertical
  3. The right main bronchus is wider and more vertical Correct answer.
  4. The left main bronchus is shorter and more vertical

Explanation

The right main bronchus is wider, shorter, and more vertical than the left, so aspirated material tends to enter it more readily. The left main bronchus is narrower and more horizontal, reducing the likelihood of aspiration. This anatomic difference is important when interpreting chest radiographs after a choking episode.

Question 41Radiographic Anatomy and Physiology

Which structure is demonstrated in profile on a lateral projection of the elbow?

  1. The medial epicondyle
  2. The radial tuberosity en face
  3. The capitulum en face
  4. The olecranon process Correct answer.

Explanation

On a lateral elbow projection the olecranon process of the ulna is seen in profile, projecting posteriorly. The medial epicondyle is best seen on AP or oblique views, and the capitulum is seen in profile on lateral views rather than en face. The radial tuberosity is demonstrated on AP views rather than en face on a lateral.

Question 42Radiographic Anatomy and Physiology

A radiograph of the abdomen shows a collection of gas in the left upper quadrant with a fluid level. Which structure is most likely the source?

  1. The gallbladder
  2. The caecum
  3. The stomach Correct answer.
  4. The rectum

Explanation

The stomach lies in the left upper quadrant and commonly contains gas with a fluid level on upright abdominal radiographs. The caecum is in the right lower quadrant, and the rectum lies in the pelvis. The gallbladder is a right upper quadrant structure and does not normally contain gas.

Question 43Radiographic Anatomy and Physiology

Which structure separates the thoracic cavity from the abdominal cavity?

  1. The pleura
  2. The diaphragm Correct answer.
  3. The mediastinum
  4. The peritoneum

Explanation

The diaphragm is the musculotendinous partition separating the thoracic cavity from the abdominal cavity. The mediastinum divides the thoracic cavity into compartments, and the pleura lines the lungs. The peritoneum lines the abdominal cavity but does not separate it from the thorax.

Question 44Radiographic Anatomy and Physiology

On a PA hand radiograph, which carpal bone articulates with the base of the first metacarpal?

  1. The trapezium Correct answer.
  2. The capitate
  3. The hamate
  4. The triquetrum

Explanation

The trapezium articulates with the base of the first metacarpal, forming the first carpometacarpal joint. The capitate articulates with the third metacarpal, and the hamate articulates with the fourth and fifth metacarpals. The triquetrum articulates with the lunate and pisiform.

Question 45Radiographic Anatomy and Physiology

Which of the following best explains why the kidneys are not seen as clearly on an AP abdominal radiograph as on an intravenous urogram?

  1. The kidneys lie anteriorly and are obscured by the liver
  2. The kidneys are located in the pelvis and overlap the bladder
  3. The kidneys are retroperitoneal and have low soft-tissue contrast Correct answer.
  4. The kidneys are intraperitoneal and surrounded by bowel gas only

Explanation

The kidneys are retroperitoneal organs with soft-tissue density similar to surrounding structures, so they are poorly seen on plain radiography. On an intravenous urogram, contrast opacifies the collecting system and improves visibility. The kidneys are not intraperitoneal, anterior, or located in the pelvis.

Question 46Radiographic Anatomy and Physiology

A radiograph of the ankle shows the distal tibia and fibula. Which structure is seen as a prominent medial projection of the distal tibia?

  1. The calcaneus
  2. The lateral malleolus
  3. The talus
  4. The medial malleolus Correct answer.

Explanation

The medial malleolus is the bony projection on the medial side of the distal tibia. The lateral malleolus is formed by the distal fibula, and the calcaneus and talus are tarsal bones of the hindfoot. Distinguishing these structures is essential when assessing ankle fractures.

Question 47Radiographic Anatomy and Physiology

Which structure is visualized as a vertical radiolucent line on a lateral chest radiograph, separating the heart from the anterior chest wall?

  1. The retrocardiac space
  2. The retrosternal clear space Correct answer.
  3. The costophrenic angle
  4. The azygo-oesophageal recess

Explanation

The retrosternal clear space is the radiolucent area between the sternum and the anterior border of the heart on a lateral chest radiograph. The retrocardiac space lies posterior to the heart, and the azygo-oesophageal recess is a mediastinal reflection. The costophrenic angle is the dependent lung recess.

Question 48Radiographic Anatomy and Physiology

Which bone of the foot is the largest and bears the body weight at the heel?

  1. The calcaneus Correct answer.
  2. The navicular
  3. The cuboid
  4. The talus

Explanation

The calcaneus is the largest tarsal bone and forms the heel, transmitting body weight to the ground. The talus articulates with the tibia and fibula to form the ankle joint, while the navicular and cuboid are smaller midfoot bones. The calcaneus is therefore the weight-bearing heel bone.

Question 49Radiographic Positioning and Procedures

For a standard PA projection of the chest in an adult, at which level should the central ray be directed?

  1. At the level of the vertebra prominens
  2. At the level of the iliac crest
  3. At the level of T7, roughly 8–10 cm below the vertebra prominens Correct answer.
  4. At the level of the xiphoid tip, roughly 20 cm below the vertebra prominens

Explanation

The PA chest central ray is centred at the T7 vertebral level, which lies approximately 8–10 cm below the vertebra prominens and corresponds to the mid-thorax. This centring ensures both apices and costophrenic angles are included on a 35 × 43 cm image receptor. Centring at the xiphoid or iliac crest would exclude the lung apices.

Question 50Radiographic Positioning and Procedures

Which projection of the hand best demonstrates the first carpometacarpal joint free of self-superimposition?

  1. PA hand
  2. Lateral hand
  3. PA hand with the fingers fanned
  4. AP oblique hand with the thumb in a true lateral position Correct answer.

Explanation

An AP oblique projection of the hand with the thumb rotated into a true lateral position clears the first CMC joint from the adjacent metacarpals. The PA hand superimposes the first CMC joint over the trapezium and second metacarpal. A standard oblique hand still leaves the thumb superimposed.