KY Water Operator flashcards
KY Water Operator · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Safe yield
- The maximum long-term pumping rate a well or wellfield can sustain without depleting storage, causing subsidence, or inducing intrusion of poorer-quality water.
- Watershed delineation
- Drawing the boundary of all land draining to an intake or well, using topographic contours and verified by dye tracing or flow monitoring where the surface divide is uncertain.
- Wellhead protection area
- The land surface around a well through which contaminants could reach the well, often divided into 1-year, 5-year, and 10-year time-of-travel zones for land-use control.
- GWUDI
- Groundwater under the direct influence of surface water; a dye trace or other evidence shows surface water reaches the well quickly, so full surface-water treatment rules apply.
- MCL versus MCLG
- The MCL is the enforceable maximum contaminant level; the MCLG is the non-enforceable health goal, often zero for carcinogens, set without considering treatment cost.
- Treatment technique rule
- A regulatory requirement specifying a required treatment method instead of a numeric MCL, used where contaminant monitoring at every sample point is impractical, such as turbidity limits.
- Tier 1 public notice
- Notice required within 24 hours for violations posing immediate health risk, such as an E. coli MCL violation or exceeding the nitrate MCL, delivered by broadcast and other means.
- Consumer Confidence Report
- Annual report due to customers by July 1 covering the prior year; it lists detected contaminants, MCLs, MCLGs, health effects, and source water information.
- Locational running annual average
- The running average of quarterly disinfection byproduct results calculated separately at each monitoring site, used to determine Stage 2 compliance for TTHM and HAA5.
- Jar test purpose
- A bench test that varies coagulant dose and pH under rapid and slow mixing to identify the dose producing the lowest settled and filtered turbidity.
- Alum alkalinity consumption
- Each mg/L of alum dosed consumes roughly 0.45 mg/L of alkalinity as CaCO3, so low-alkalinity waters may need lime or caustic to hold coagulation pH.
- Velocity gradient G
- A measure of mixing intensity in reciprocal seconds; rapid mix uses roughly 250-1000 per second briefly, while flocculation uses about 10-75 per second for 15-45 minutes.
- Surface overflow rate
- Filter or clarifier flow divided by its surface area, expressed in gpm/ft2; it sets the settling velocity a particle must exceed to be removed in a basin.
- Media uniformity coefficient
- The ratio of the 60th-percentile size (d60) to the effective size (d10) of filter media; a lower value means a more uniform bed and better backwash behavior.
- Filter loading rate
- Flow divided by filter surface area, typically 2-6 gpm/ft2 for rapid gravity filters; exceeding design rate raises effluent turbidity and shortens filter runs.
- Combined filter effluent limit
- Conventional and direct filtration systems must keep combined filter effluent turbidity at or below 0.3 NTU in at least 95% of monthly readings, with no reading above 1 NTU.
- Backwash media expansion
- Sand beds are expanded roughly 15-25% during backwash at about 20 C; colder water is denser and needs a higher backwash rate for the same expansion.
- CT concept
- The product of disinfectant residual concentration in mg/L and effective contact time in minutes, compared against the required CT for the target log inactivation.
- Baffling factor
- The ratio t10/T describing how much of a basin's theoretical detention time is actually credited, ranging from about 0.1 in unbaffled basins to 0.7 in well-baffled ones.
- Chlorine species and pH
- Hypochlorous acid dominates below about pH 6.5 and is far more biocidal than hypochlorite ion, which dominates above pH 8.5, so disinfection weakens at high pH.
- Chloramination tradeoff
- Chloramines form fewer regulated THMs and HAAs than free chlorine but require a free chlorine contact period first and nitrification monitoring in the distribution system.
- Minimum distribution pressure
- At least 20 psi must be maintained at ground level throughout the distribution system under all conditions, including during fire flow, to prevent contamination intrusion.
- Hazen-Williams formula
- hf = 10.44 * L * Q^1.852 / (C^1.852 * d^4.87) in US customary units, where C is the roughness coefficient, about 130-140 for new cement-lined ductile iron.
- Unidirectional flushing
- Flushing in the normal direction of flow at velocities of about 5 ft/s or more, with valves sequenced to isolate a main, to scour biofilm and sediment from the pipe.
- Main disinfection per AWWA C651
- New or repaired water mains are chlorinated, typically at 25 or 50 mg/L for 24 hours depending on method, flushed, and sampled before being placed in service.
- Pump affinity laws
- For a given pump, flow varies with speed, head with speed squared, and power with speed cubed, so a 10% speed reduction lowers power by about 27%.
- Brake horsepower formula
- BHP = (Q * TDH) / (3960 * pump efficiency), with Q in gpm and TDH in feet; dividing by motor efficiency gives wire-to-water power demand.
- NPSH available
- Atmospheric pressure head plus static suction head minus vapor pressure head minus suction friction losses; it must exceed NPSH required by a margin to prevent cavitation.
- Backsiphonage versus backpressure
- Backsiphonage results from negative pressure in the supply main; backpressure occurs when downstream pressure, such as from a boiler or pump, exceeds supply pressure.
- Reduced pressure principle assembly
- A testable backflow device with two check valves and a relief valve that protects against both backpressure and backsiphonage for high-hazard connections; tested at least annually.
- Air gap separation
- The highest-degree backflow protection: a physical gap of at least twice the effective pipe diameter, with a minimum of 1 inch, between the supply outlet and the flood rim.
- Bacteriological holding time
- Drinking water bacteriological samples must begin analysis within 30 hours of collection; they are collected in sterile thiosulfate-treated bottles from a flushed, clean tap.