Safe yield
The maximum long-term pumping rate a well or wellfield can sustain without depleting storage, causing subsidence, or inducing intrusion of poorer-quality water.
Watershed delineation
Drawing the boundary of all land draining to an intake or well, using topographic contours and verified by dye tracing or flow monitoring where the surface divide is uncertain.
Wellhead protection area
The land surface around a well through which contaminants could reach the well, often divided into 1-year, 5-year, and 10-year time-of-travel zones for land-use control.
GWUDI
Groundwater under the direct influence of surface water; a dye trace or other evidence shows surface water reaches the well quickly, so full surface-water treatment rules apply.
MCL versus MCLG
The MCL is the enforceable maximum contaminant level; the MCLG is the non-enforceable health goal, often zero for carcinogens, set without considering treatment cost.
Treatment technique rule
A regulatory requirement specifying a required treatment method instead of a numeric MCL, used where contaminant monitoring at every sample point is impractical, such as turbidity limits.
Tier 1 public notice
Notice required within 24 hours for violations posing immediate health risk, such as an E. coli MCL violation or exceeding the nitrate MCL, delivered by broadcast and other means.
Consumer Confidence Report
Annual report due to customers by July 1 covering the prior year; it lists detected contaminants, MCLs, MCLGs, health effects, and source water information.
Locational running annual average
The running average of quarterly disinfection byproduct results calculated separately at each monitoring site, used to determine Stage 2 compliance for TTHM and HAA5.
Jar test purpose
A bench test that varies coagulant dose and pH under rapid and slow mixing to identify the dose producing the lowest settled and filtered turbidity.
Alum alkalinity consumption
Each mg/L of alum dosed consumes roughly 0.45 mg/L of alkalinity as CaCO3, so low-alkalinity waters may need lime or caustic to hold coagulation pH.
Velocity gradient G
A measure of mixing intensity in reciprocal seconds; rapid mix uses roughly 250-1000 per second briefly, while flocculation uses about 10-75 per second for 15-45 minutes.
Surface overflow rate
Filter or clarifier flow divided by its surface area, expressed in gpm/ft2; it sets the settling velocity a particle must exceed to be removed in a basin.
Media uniformity coefficient
The ratio of the 60th-percentile size (d60) to the effective size (d10) of filter media; a lower value means a more uniform bed and better backwash behavior.
Filter loading rate
Flow divided by filter surface area, typically 2-6 gpm/ft2 for rapid gravity filters; exceeding design rate raises effluent turbidity and shortens filter runs.
Combined filter effluent limit
Conventional and direct filtration systems must keep combined filter effluent turbidity at or below 0.3 NTU in at least 95% of monthly readings, with no reading above 1 NTU.
Backwash media expansion
Sand beds are expanded roughly 15-25% during backwash at about 20 C; colder water is denser and needs a higher backwash rate for the same expansion.
CT concept
The product of disinfectant residual concentration in mg/L and effective contact time in minutes, compared against the required CT for the target log inactivation.
Baffling factor
The ratio t10/T describing how much of a basin's theoretical detention time is actually credited, ranging from about 0.1 in unbaffled basins to 0.7 in well-baffled ones.
Chlorine species and pH
Hypochlorous acid dominates below about pH 6.5 and is far more biocidal than hypochlorite ion, which dominates above pH 8.5, so disinfection weakens at high pH.
Chloramination tradeoff
Chloramines form fewer regulated THMs and HAAs than free chlorine but require a free chlorine contact period first and nitrification monitoring in the distribution system.
Minimum distribution pressure
At least 20 psi must be maintained at ground level throughout the distribution system under all conditions, including during fire flow, to prevent contamination intrusion.
Hazen-Williams formula
hf = 10.44 * L * Q^1.852 / (C^1.852 * d^4.87) in US customary units, where C is the roughness coefficient, about 130-140 for new cement-lined ductile iron.
Unidirectional flushing
Flushing in the normal direction of flow at velocities of about 5 ft/s or more, with valves sequenced to isolate a main, to scour biofilm and sediment from the pipe.
Main disinfection per AWWA C651
New or repaired water mains are chlorinated, typically at 25 or 50 mg/L for 24 hours depending on method, flushed, and sampled before being placed in service.
Pump affinity laws
For a given pump, flow varies with speed, head with speed squared, and power with speed cubed, so a 10% speed reduction lowers power by about 27%.
Brake horsepower formula
BHP = (Q * TDH) / (3960 * pump efficiency), with Q in gpm and TDH in feet; dividing by motor efficiency gives wire-to-water power demand.
NPSH available
Atmospheric pressure head plus static suction head minus vapor pressure head minus suction friction losses; it must exceed NPSH required by a margin to prevent cavitation.
Backsiphonage versus backpressure
Backsiphonage results from negative pressure in the supply main; backpressure occurs when downstream pressure, such as from a boiler or pump, exceeds supply pressure.
Reduced pressure principle assembly
A testable backflow device with two check valves and a relief valve that protects against both backpressure and backsiphonage for high-hazard connections; tested at least annually.
Air gap separation
The highest-degree backflow protection: a physical gap of at least twice the effective pipe diameter, with a minimum of 1 inch, between the supply outlet and the flood rim.
Bacteriological holding time
Drinking water bacteriological samples must begin analysis within 30 hours of collection; they are collected in sterile thiosulfate-treated bottles from a flushed, clean tap.