LA HVAC key terms
LA HVAC · Get comfortable with the vocabulary.
- Lockout/Tagout (LOTO)
- Related: Personal Protective Equipment (PPE), Arc Flash Boundary
A required safety procedure in which the energy source feeding equipment is de-energized, isolated, locked, and tagged so it cannot be restarted while a technician services or repairs it.
- Personal Protective Equipment (PPE)
- Related: Lockout/Tagout (LOTO), Brazing and Soldering Safety
Wearable gear such as safety glasses, gloves, respirators, and hearing protection that reduces a worker's exposure to hazards on the job site.
- Arc Flash Boundary
- Related: Lockout/Tagout (LOTO), Multimeter
The distance from energized electrical equipment within which a person could receive a second-degree burn from an arc flash, establishing where shock and burn protection is required.
- Brazing and Soldering Safety
- Related: Nitrogen Purge, Personal Protective Equipment (PPE)
Practices for joining tubing with heat, including fire watch, shielding combustibles, purging with nitrogen, and ventilating fumes from flux and refrigerant decomposition products.
- Manifold Gauge Set
- Related: Superheat, Subcooling
A tool with high-side and low-side gauges and hoses used to read system pressures, evacuate, and charge refrigerant. Hoses and manifolds must be rated for the refrigerant in use.
- Vacuum Micron Gauge
- Related: Triple Evacuation, Manifold Gauge Set
An electronic instrument that measures deep vacuum in microns during evacuation, confirming that moisture and non-condensable gases have been removed before charging a system.
- Superheat
- Related: Subcooling, TXV (Thermostatic Expansion Valve)
The number of degrees a vapor is above its saturation temperature at a given pressure. Measured at the evaporator outlet, it indicates how well the metering device is feeding the coil.
- Subcooling
- Related: Superheat, Refrigerant Charge Verification
The number of degrees a liquid is below its saturation temperature at a given pressure. Measured at the condenser outlet, it verifies the refrigerant charge and condenser performance.
- TXV (Thermostatic Expansion Valve)
- Related: Superheat, Evaporator
A metering device that regulates refrigerant flow into the evaporator by maintaining a target superheat, responding to bulb temperature and evaporator pressure.
- Evaporator
- Related: Condenser, Superheat
The indoor coil where low-pressure liquid refrigerant absorbs heat from the conditioned air and boils into vapor, producing the cooling effect.
- Condenser
- Related: Evaporator, Subcooling
The outdoor coil where high-pressure refrigerant vapor rejects heat to outdoor air and condenses into a liquid, completing the refrigeration cycle.
- Compressor
- Related: Condenser, Refrigerant Charge Verification
The heart of the refrigeration cycle; it raises refrigerant pressure and temperature, moving vapor from the evaporator to the condenser and driving the entire circuit.
- Manual J Load Calculation
- Related: Manual D Duct Design, Manual S Equipment Selection
An industry method for estimating a building's heating and cooling loads from envelope, orientation, occupancy, and climate data, used to size equipment correctly.
- Manual D Duct Design
- Related: Manual J Load Calculation, Equivalent Length
An industry method for sizing ducts based on available static pressure, friction rate, and equivalent lengths of fittings so each room receives its design airflow.
- Manual S Equipment Selection
- Related: Manual J Load Calculation, Sensible Heat Ratio
An industry procedure for matching selected heating and cooling equipment to the calculated loads, checking sensible and latent capacity at design conditions.
- Equivalent Length
- Related: Manual D Duct Design, Friction Rate
The friction loss of a duct fitting expressed as an equivalent straight run of duct, added to the physical run to determine total effective length.
- Friction Rate
- Related: Equivalent Length, Manual D Duct Design
The pressure drop per unit length of duct, usually inches of water per 100 feet, used to size ducts for a given available static pressure.
- Sensible Heat Ratio
- Related: Manual S Equipment Selection, Manual J Load Calculation
The fraction of total cooling capacity that removes sensible heat, calculated as sensible capacity divided by total capacity; important for humidity control.
- Combustion Air
- Related: Carbon Monoxide (CO) Safety, Draft Hood
The air supplied to a fuel-burning appliance for complete combustion; inadequate supply causes carbon monoxide production and unsafe operation.
- Carbon Monoxide (CO) Safety
- Related: Combustion Air, Draft Hood
Procedures for preventing and detecting carbon monoxide, including combustion analysis, flue inspection, and use of personal CO monitors during service calls.
- Draft Hood
- Related: Combustion Air, Carbon Monoxide (CO) Safety
A device on atmospheric gas furnaces that draws dilution air and maintains a stable negative pressure at the appliance flue collar, preventing spillage of combustion products.
- Heat Exchanger
- Related: Carbon Monoxide (CO) Safety, Combustion Air
The metal component separating combustion gases from supply air in a furnace; cracks or holes allow carbon monoxide to enter the airstream and require replacement.
- Refrigerant Charge Verification
- Related: Superheat, Subcooling
The process of confirming correct refrigerant quantity using superheat, subcooling, or weigh-in methods, following manufacturer charging charts and system conditions.
- Triple Evacuation
- Related: Vacuum Micron Gauge, Nitrogen Purge
An evacuation method using nitrogen and vacuum in alternating cycles to remove moisture and non-condensables from a system before charging.
- Nitrogen Purge
- Related: Brazing and Soldering Safety, Triple Evacuation
Flowing dry nitrogen through tubing during brazing to prevent internal oxidation, and using nitrogen pressure for leak testing and evacuation support.
- Recovery Cylinder
- Related: Refrigerant Charge Verification
A DOT-approved, color-coded vessel used to store recovered refrigerant; it must not be overfilled and must be rated for the refrigerant recovered.
- Multimeter
- Related: Arc Flash Boundary, Run Capacitor
A test instrument measuring voltage, resistance, and current; used to verify power, check continuity, and diagnose electrical faults in controls and motors.
- Run Capacitor
- Related: Multimeter, Contactor
A capacitor that stays in the circuit during motor operation to improve torque and phase angle on permanent split capacitor motors; a failed one can prevent starting.
- Contactor
- Related: Run Capacitor, Multimeter
An electrically controlled switch that uses a coil to close heavy-duty contacts, supplying power to compressors, condensers, and other high-current loads.
- Sequence of Operation
- Related: Contactor, Multimeter
The ordered steps a control system follows from a call for heat or cool through safeties, fan, and shutdown, used to diagnose where a system fails.
- Line Set
- Related: Nitrogen Purge, Brazing and Soldering Safety
The pair of copper lines connecting indoor and outdoor units, consisting of the liquid line and the larger suction line, properly insulated and supported.
- Sheet Metal Duct Fabrication
- Related: Manual D Duct Design, Equivalent Length
Cutting, forming, and joining galvanized steel duct using patterns, seams, and reinforcement to meet airflow and leakage requirements.
- Condensate Trap
- Related: Evaporator
A water seal in the drain line that prevents air from being drawn into or blown out of the drain pan, ensuring condensate drains properly.
- Permit and Inspection Requirements
- Related: Louisiana Mechanical Licensing, Code Compliance
Local rules requiring permits and inspections for HVAC installations; work must comply with adopted codes and be inspected before being placed in service.
- Louisiana Mechanical Licensing
- Related: Permit and Inspection Requirements, Code Compliance
State and local requirements for contractors and technicians to hold the appropriate mechanical license or registration before performing or contracting HVAC work.
- Code Compliance
- Related: Permit and Inspection Requirements, Louisiana Mechanical Licensing
Adherence to adopted mechanical, fuel gas, and energy codes, including manufacturer instructions, which govern installation, ventilation, and safety requirements.
- Change Order
- Related: Lien Rights and Notice, Contract Documents
A written document signed by the owner and contractor that modifies the contract scope, price, or schedule before the additional work is performed.
- Lien Rights and Notice
- Related: Change Order, Contract Documents
A contractor's legal claim against property for unpaid work, subject to deadlines and notice requirements that vary by state and must be tracked carefully.
- Contract Documents
- Related: Change Order, Lien Rights and Notice
The complete set of drawings, specifications, addenda, and agreement forms that define the work, price, and obligations of the parties.