Fixture unit (FU)
A unit that expresses the load-producing effect of a fixture on the drainage or water supply system, allowing dissimilar fixtures to be added into one total design load.
Drainage fixture units
Total DFU in a building determine the minimum building drain and building sewer size using the code sizing table, not the simple sum of pipe areas.
Static pressure loss per foot
Each foot of elevation gain reduces water pressure by about 0.433 psi, because one psi equals 2.31 feet of head in a column of water.
Trap seal depth
The water seal in a fixture trap must be between 2 and 4 inches deep; a seal outside this range can be siphoned or allow sewer gas to pass.
Vent terminal height
A vent stack must extend at least 6 inches above the roof, or 12 inches above a roof used for other purposes, and 10 feet from air intakes.
Cleanout location
Cleanouts are required at the base of each stack, at the building drain, at direction changes over 45 degrees, and at intervals not exceeding 100 feet.
Air gap
The only absolute backflow protection: an unobstructed vertical distance of at least twice the supply pipe diameter and never less than 1 inch above the flood rim.
RPZ assembly
A reduced pressure zone backflow preventer is required for high-hazard connections and must be tested annually by a certified tester.
Hydrostatic test
The standard DWV test: fill the system with water to at least 10 feet of head above the highest fitting and hold for 15 minutes before inspection.
Trench protective system
Any excavation 5 feet or deeper requires sloping, shoring, or a trench box, and spoil piles must be kept at least 2 feet from the edge.
Copper tube types
Type K is thickest and used underground, Type L is standard and most common, Type M is thin wall and permitted aboveground only.
Water piping test pressure
Water supply piping is tested at 50 psi or working pressure, whichever is greater, for at least 60 minutes with no pressure drop.
T&P relief discharge
A water heater temperature and pressure relief valve must discharge full size, terminate within 6 inches of the floor, and never be trapped or reduced.
Gas piping test
Gas piping is tested with air or inert gas at 10 psi for at least 30 minutes for systems up to 125 psi working pressure, witnessed by the code official.
Sediment trap
A sediment trap is required at the appliance connection on gas piping to catch debris before it reaches the appliance controls.
Building sewer minimum size
A building sewer serving a building with water closets must be at least 4 inches; a building without water closets may use 3 inches.
Sewer cleanout spacing
Sewer cleanouts are required at the property line, at the building sewer, and at intervals not exceeding 100 feet, with gas-tight covers.
Roof drain sizing
Roof drain size depends on roof area, the local 100-year one-hour rainfall intensity, and the drain size, using the code sizing table.
Backwater valve
A backwater valve is required where the building drain is below the level of the public sewer or where the sewer may surcharge, and must be accessible.
Permit expiration
A plumbing permit expires if work does not start within 180 days of issuance or is suspended for 180 days; a new permit and fee are then required.
Rough-in inspection
The rough-in inspection must be approved before any DWV or water piping is concealed, and the code official must be given notice to schedule it.
Stop-work order
The code official may issue a stop-work order for unpermitted or unsafe work, and work may not resume until the order is lifted.
Water closet clearance
A water closet needs at least 15 inches from centerline to side wall and 21 inches in front of the bowl for code-compliant clearance.
Clothes washer standpipe
A clothes washer requires a 2-inch standpipe with a trap and 2-inch vent, between 18 and 42 inches above the floor.
Dishwasher drain connection
A dishwasher must drain through an air gap or high-loop connection to prevent backflow, discharging to the sink drain or a separate trap.
Floor drain trap primer
A floor drain trap needs a minimum 2-inch seal and a trap primer where the trap may evaporate, plus a strainer at the outlet.
Water service cover
Buried water service pipe must have at least 12 inches of cover below the frost line, or the local depth requirement, typically 18 to 24 inches in Louisiana.
Water hammer arrestor
A water hammer arrestor is required at quick-closing valves and at the end of long runs to absorb pressure surges and protect the piping.
Pressure vacuum breaker
A pressure vacuum breaker is used for lawn irrigation and must be installed at least 12 inches above the highest downstream outlet.
Hose bibb vacuum breaker
A listed hose bibb vacuum breaker is required on all sill cocks and hose connections and must not be removed by the user.
Call 811 before digging
Before excavating, call 811 to locate underground utilities, wait the required time, and hand-dig within 24 inches of marked utilities.
Confined space entry
Entry into excavations deeper than 4 feet, tanks, or vaults requires atmospheric testing for oxygen, flammable gas, and hydrogen sulfide before and during entry.