LA Plumber key terms
LA Plumber · Get comfortable with the vocabulary.
- Uniform Plumbing Code (UPC)
- Related: Authority Having Jurisdiction (AHJ), Permit, Code Adoption
A model plumbing code adopted by many jurisdictions as the basis for local plumbing regulation. It sets minimum standards for design, materials, installation, and inspection of plumbing systems.
- Authority Having Jurisdiction (AHJ)
- Related: Uniform Plumbing Code (UPC), Permit, Inspection
The official, agency, or individual responsible for enforcing a code and approving materials, installations, and interpretations. The AHJ conducts inspections and may grant variances where the code allows.
- Permit
- Related: Inspection, Authority Having Jurisdiction (AHJ), Rough-In
A written authorization from the AHJ allowing specified plumbing work to proceed. Work covered by a permit requires inspection and approval before the system may be placed in service.
- Rough-In
- Related: Inspection, Permit, DWV System
The stage of construction when piping, fittings, and supports are installed but fixtures and final connections are not yet set. Rough-in inspection must pass before walls or slabs are closed.
- Inspection
- Related: Rough-In, Permit, Hydrostatic Test
An official review of plumbing work by the AHJ at defined stages, such as rough-in, water supply testing, and final. Approval confirms the work meets code before it is covered or placed in service.
- Fixture Unit
- Related: Drainage Fixture Unit (DFU), Water Supply Fixture Unit (WSFU), Building Drain
A dimensionless measure of the probable load a fixture places on the drainage or water supply system. One fixture unit approximates the discharge of a lavatory; larger fixtures carry higher values.
- Drainage Fixture Unit (DFU)
- Related: Fixture Unit, Building Drain, Slope
The fixture-unit value assigned to a fixture for sizing the drainage system, based on its discharge rate and usage. DFU values are summed to determine pipe sizes and drain capacity.
- Water Supply Fixture Unit (WSFU)
- Related: Fixture Unit, Probable Demand, Developed Length
The fixture-unit value used to size water supply piping, reflecting a fixture's flow demand and diversity of use. Total WSFU is converted to probable demand in gallons per minute.
- Probable Demand
- Related: Water Supply Fixture Unit (WSFU), Developed Length, Water Service
The estimated peak water flow, usually in gallons per minute, that a building's fixtures will require simultaneously. It is derived from total water supply fixture units and used to size the water service and mains.
- Developed Length
- Related: Probable Demand, Pressure Loss, Water Service
The total equivalent pipe length of a water supply run, including straight pipe plus allowances for fittings and valves. It is used with probable demand to select pipe size from sizing tables.
- Slope
- Related: Drainage Fixture Unit (DFU), Building Drain, Trap Arm
The downward pitch of horizontal drainage pipe, expressed as fall per unit of run, such as one-quarter inch per foot. Adequate slope carries solids while maintaining self-cleansing velocity.
- Water Service
- Related: Probable Demand, Hydrostatic Test, Backflow Preventer
The pipe and fittings that convey potable water from the water main or source to the building, ending at the first shutoff valve or meter. It must be sized for probable demand and protected from contamination.
- Hydrostatic Test
- Related: Water Service, Inspection, Air Test
A pressure test in which a water supply system is filled with water and pressurized above working pressure for a set period to reveal leaks. It must be witnessed or documented for inspection approval.
- Air Test
- Related: Hydrostatic Test, DWV System, Inspection
A pressure test using compressed air instead of water, permitted in some circumstances for DWV or water piping. The test pressure and duration are specified by code and must be monitored with a gauge.
- Water Hammer
- Related: Water Service, Shock Arrestor, Pressure-Reducing Valve
A pressure surge caused by sudden stoppage of water flow, producing banging and potential pipe damage. It is controlled with air chambers, arrestors, or properly sized and supported piping.
- Shock Arrestor
- Related: Water Hammer, Water Service
A device containing a trapped air cushion or mechanical element that absorbs pressure surges in water piping. It is installed near quick-closing valves such as flushometers or solenoid valves.
- DWV System
- Related: Vent Stack, Trap Seal, Building Drain
The combined drain, waste, and vent piping that removes sewage and wastewater while admitting air to protect trap seals. Drainage piping slopes to a building drain; vents equalize pressure.
- Vent Stack
- Related: DWV System, Trap Seal, Air Gap
A vertical vent pipe that extends from the drainage system to outdoor air, providing pressure relief for fixtures on multiple floors. It may serve as a soil or waste stack vent where code permits.
- Trap Seal
- Related: Vent Stack, Trap Arm, DWV System
The water held in a fixture trap that blocks sewer gas from entering the building. Its depth is code-specified, and it must be protected from siphonage by proper venting.
- Trap Arm
- Related: Trap Seal, Slope, DWV System
The section of drain pipe between a fixture trap and the branch or stack it connects to. Its length and slope are limited by code to preserve the trap seal and allow proper drainage.
- Building Drain
- Related: Building Sewer, Drainage Fixture Unit (DFU), Cleanout
The lowest horizontal drainage pipe inside the building that receives soil and waste from stacks and branches. It connects to the building sewer at or outside the foundation wall.
- Building Sewer
- Related: Building Drain, Cleanout, Slope
The pipe carrying sewage from the building drain to the public sewer or private disposal system. It is sized by drainage fixture units and must maintain required slope.
- Cleanout
- Related: Building Drain, Building Sewer
An accessible fitting with a removable cap that allows the drainage system to be rodded or inspected. Cleanouts are required at specified intervals, at changes in direction, and at the building sewer.
- Storm Drainage
- Related: Building Sewer, Backwater Valve, Sump Pump
The system that collects and conveys rainwater, groundwater, and surface runoff from roofs, yards, and foundations. It must be kept separate from sanitary drainage unless combined systems are approved.
- Backwater Valve
- Related: Storm Drainage, Backflow Preventer
A one-way valve installed on a drainage line to prevent sewage from reversing into a building during main surcharge. It must be accessible for inspection and maintenance.
- Sump Pump
- Related: Storm Drainage, Air Gap
A pump installed in a sump pit to remove accumulated groundwater or stormwater from a building. Discharge must be routed to an approved location and may not create a cross-connection.
- Backflow
- Related: Backflow Preventer, Air Gap, Cross-Connection
The unintended reverse flow of water or other fluids into the potable supply. It occurs by backpressure or backsiphonage and is prevented by approved assemblies, devices, or air gaps.
- Backflow Preventer
- Related: Backflow, Cross-Connection, Air Gap
An approved assembly or device that stops reverse flow into the potable water system. Selection depends on the degree of hazard and whether backpressure or backsiphonage is possible.
- Air Gap
- Related: Backflow, Cross-Connection, Sump Pump
A physical separation between a potable water outlet and the flood-level rim of a receiving fixture or vessel. It is the most reliable form of backflow protection and requires no moving parts.
- Cross-Connection
- Related: Backflow, Backflow Preventer, Air Gap
Any actual or potential link between the potable water system and a source of contamination or pollution. Cross-connections must be eliminated or protected by an approved backflow assembly.
- Water Heater
- Related: Temperature and Pressure Relief Valve, Fuel Gas Piping, Sediment Trap
An appliance that heats and stores potable water for domestic use. It requires a temperature and pressure relief valve, a discharge pipe, and proper venting or combustion air where fuel-fired.
- Temperature and Pressure Relief Valve
- Related: Water Heater, Expansion Tank
A safety device on a water heater that opens if temperature or pressure exceeds set limits. Its discharge must terminate safely and may not be capped, trapped, or reduced in size.
- Expansion Tank
- Related: Temperature and Pressure Relief Valve, Water Heater
A vessel that absorbs the volume increase of water as it is heated in a closed system. It protects piping and the water heater from excess pressure and prevents relief valve discharge.
- Fuel Gas Piping
- Related: Sediment Trap, Water Heater
The piping system that delivers natural gas or propane from the meter or tank to appliances. It is sized for pressure drop and must be tested, bonded, and installed with approved materials.
- Sediment Trap
- Related: Fuel Gas Piping, Water Heater
A dirt-leg fitting installed on a gas line near an appliance to catch debris before it reaches the controls. It is required by code and must be installed in the flow direction specified.
- Personal Protective Equipment (PPE)
- Related: Confined Space, Job-Site Housekeeping
Safety gear such as eye protection, gloves, hearing protection, and respirators worn to reduce injury risk. It is required for tasks like soldering, cutting, and working with chemicals.
- Confined Space
- Related: Personal Protective Equipment (PPE), Job-Site Housekeeping
A space with limited entry and exit that is not designed for continuous occupancy, such as a pit or vault. Entry may require atmospheric testing, a permit, and an attendant.
- Job-Site Housekeeping
- Related: Personal Protective Equipment (PPE), Confined Space
Keeping work areas clean, organized, and free of hazards such as spills, scrap, and blocked exits. Good housekeeping prevents slips, trips, and fires and is required on every site.