LA Roofing Contractor · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Asphalt shingle minimum slope
- Asphalt shingles require a roof slope of at least 2:12. Between 2:12 and 4:12, install double underlayment; below 2:12, use a low-slope roof system approved for that slope.
- Double underlayment threshold
- For asphalt shingles, a roof slope from 2:12 up to 4:12 requires two layers of underlayment overlapped according to code or the shingle manufacturer's printed instructions.
- Step flashing placement
- Install step flashing at roof-to-sidewall intersections, woven with each shingle course, with at least a 4-inch vertical leg and 2-inch overlap between successive pieces.
- Roof ventilation ratio
- IRC minimum attic ventilation is 1 square foot of net free vent area per 150 square feet of attic floor area; the ratio may be 1:300 with balanced intake and exhaust vents.
- Valley flashing types
- Roof valleys may use open metal flashing, woven shingles, or cut shingles. Open metal valleys provide direct drainage and are common in heavy-rainfall areas such as Louisiana.
- Standing seam metal slope
- Standing-seam metal roofs generally require a minimum slope of 1:4, but manufacturers may permit lower slopes with specific seam profiles and sealants; follow the approved installation manual.
- Roof sheathing minimum thickness
- IRC roof sheathing is typically minimum 15/32-inch wood structural panel for rafters spaced up to 24 inches on center, with final thickness determined by span rating and fastener schedule.
- Ice dam membrane location
- Ice-dam protection membrane is required along eaves in areas with a history of ice dams; it extends from the eave edge to at least 24 inches inside the exterior wall line.
- IRC Chapter 9 scope
- Chapter 9 of the International Residential Code regulates roof assemblies, including roof covering materials, flashing, drainage, and attic ventilation requirements for one- and two-family dwellings.
- ASTM D3462
- ASTM D3462 is the standard specification for asphalt shingles made from glass felt and surfaced with mineral granules; it sets physical and performance requirements for those shingles.
- UL 790 fire rating
- UL 790 tests roof covering fire resistance and assigns Class A, B, or C ratings. Class A offers the highest protection and is often required in wildfire-prone or code-specified areas.
- Wind uplift test standards
- Asphalt shingle wind resistance is commonly evaluated under ASTM D7158 or ASTM D3161. The resulting classification indicates the design wind speed the shingle assembly can resist.
- Roof plan slope notation
- Roof slope on plans is written as rise:run, such as 4:12, meaning 4 inches of vertical rise per 12 inches of horizontal run. Slope differs from pitch, which is rise over span.
- Plan scale interpretation
- A drawing scale such as 1/4 inch = 1 foot means one quarter inch on the printed plan equals twelve inches in the actual building; verify scale before measuring dimensions.
- Roof plan symbols
- Ridge lines show the highest intersection of roof planes, hip lines slope downward from a ridge, and valley lines show where two roof planes meet internally to channel water.
- Fastener schedule meaning
- A fastener schedule specifies nail or screw type, length, diameter, and spacing for each connection. Roof sheathing commonly uses 8d nails at edge and field spacing set by code tables.
- LSLBC roofing license
- The Louisiana State Licensing Board for Contractors issues specialty licenses, including roofing, for qualifying contractors. License classification and project value thresholds determine when a license is legally required.
- Written change order
- A change order is a written document signed by owner and contractor that modifies scope, price, or schedule. It prevents disputes by documenting agreed changes before work proceeds.
- Louisiana Private Works Act
- The Louisiana Private Works Act governs mechanics' liens and privilege claims on private construction projects. Contractors and suppliers must meet notice and filing deadlines to preserve lien rights.
- Certificate of insurance
- A certificate of insurance summarizes a contractor's general liability, auto, and workers' compensation coverage. It lists policy limits, insurer, insured name, and expiration dates for verification.
- Retainage purpose
- Retainage is a percentage of each payment withheld by the owner until project completion. It protects the owner against incomplete work, liens, and punch-list items.
- Home improvement registration
- Louisiana requires home improvement contractors to register with the state for certain residential projects within specified dollar ranges. Registration is separate from a specialty contractor license.
- Workers compensation requirement
- Louisiana employers with employees must carry workers' compensation insurance or qualify for an approved self-insurance plan. Roofing contractors should verify coverage before starting any job.
- Contract scope clause
- A scope-of-work clause defines exactly what the contractor will furnish and install, including materials, removal, cleanup, and exclusions. Clear scope reduces disputes and unpaid extras.
- OSHA fall protection height
- OSHA construction rules generally require fall protection when workers are exposed to falls of 6 feet or more. Roofing work commonly uses guardrails, safety nets, or personal fall arrest systems.
- Ladder setup angle
- Extension ladders should be set at a 4:1 ratio: one foot of horizontal distance for every four feet of working height, and extend at least 3 feet above the landing.
- Personal fall arrest anchorage
- Personal fall arrest systems require an anchorage capable of supporting at least 5,000 pounds per worker, a full-body harness, and a lanyard or deceleration device limiting fall forces.
- Guardrail height
- Standard guardrails have a top rail about 42 inches above the walking surface and a midrail at approximately 21 inches, with toe boards where materials may fall.
- Warning line distance
- On low-slope roofs, a warning line is often placed at least 15 feet from the roof edge to designate a controlled work area, but it is not a substitute for fall protection where required.
- Power line clearance
- Keep ladders, scaffolding, and conductive tools at least 10 feet away from energized overhead power lines; higher voltages require greater clearance under OSHA table rules.
- Nail gun safe practice
- Never point a nail gun at any person, disconnect the air supply before clearing jams, and keep fingers clear of the firing path. Use the trigger type specified by the manufacturer.
- Heat illness prevention
- In hot Louisiana weather, provide drinking water, scheduled rest breaks, shade, and acclimatization for new workers. Recognize confusion, cramps, and fainting as warning signs.