NVQ L4 Automobile AC Technician · Get comfortable with the vocabulary.

F-gas regulation

Legislation controlling fluorinated greenhouse gases, requiring certified handling, leak checks, recovery of refrigerant and record keeping. It sets global warming potential limits and bans venting to atmosphere.

Related: Global warming potential (GWP), Refrigerant recovery, Venting
Global warming potential (GWP)

A number expressing how much heat one kilogram of a gas traps over 100 years compared with carbon dioxide. Used to compare refrigerants and to calculate CO2-equivalent charge sizes for regulations.

Related: F-gas regulation, CO2 equivalent charge, Alternative refrigerant
CO2 equivalent charge

The mass of refrigerant in a system multiplied by its global warming potential, expressed in tonnes of CO2 equivalent. It determines which leak-check intervals and record duties apply.

Related: Global warming potential (GWP), F-gas regulation, Leak check interval
Safety data sheet (SDS)

A document supplied with a chemical listing its hazards, first-aid measures, handling and storage advice and disposal requirements. It must be available where refrigerants and oils are stored or used.

Related: Personal protective equipment (PPE), Refrigerant cylinder
Personal protective equipment (PPE)

Wearable protection such as safety glasses, cryogenic gloves and face shield used when handling refrigerants and oils. It guards against frostbite, eye splash and skin contact during recovery and charging.

Related: Safety data sheet (SDS), Liquid refrigerant frostbite
Liquid refrigerant frostbite

Tissue damage caused when liquid refrigerant contacts skin and boils off rapidly, freezing tissue. Affected areas must not be rubbed; flush with lukewarm water and seek medical help.

Related: Personal protective equipment (PPE), Asphyxiation risk
Asphyxiation risk

The danger that heavier-than-air refrigerant vapour displaces oxygen in pits, service bays or vehicle interiors. Work areas need ventilation and never-smell-testing rules; entry into confined spaces requires assessment.

Related: Liquid refrigerant frostbite, Venting
Venting

Deliberately releasing refrigerant to atmosphere, which is prohibited in most jurisdictions. Recovered refrigerant must instead be collected in a suitable cylinder for recycling, reclamation or destruction.

Related: Refrigerant recovery, F-gas regulation
Refrigerant recovery

The process of removing refrigerant from a system and storing it in an external cylinder without testing or cleaning it. Recovery is the first stage before recycling, reclamation or disposal.

Related: Recycling, Reclamation, Recovery cylinder
Recycling

Reducing contaminants in recovered refrigerant by oil separation and filtration so it can be reused, typically in the same vehicle. It does not achieve the purity of reclamation and requires dedicated equipment.

Related: Refrigerant recovery, Reclamation, Moisture indicator
Reclamation

Reprocessing recovered refrigerant to new-product specification by an approved facility, including chemical analysis and certification. Reclaimed refrigerant is supplied with documentation of purity and composition.

Related: Recycling, Refrigerant recovery
Recovery cylinder

A refillable vessel rated and marked for recovered refrigerant, never filled above its stated capacity and never mixed with unknown gases. It carries a tare weight and a maximum fill limit, often 80 percent.

Related: Refrigerant recovery, Tare weight, Non-condensable gas
Tare weight

The empty weight of a refrigerant cylinder, stamped on the neck or shoulder. Gross weight minus tare weight gives the refrigerant content, which must not exceed the permitted fill.

Related: Recovery cylinder, Cylinder fill limit
Cylinder fill limit

The maximum mass of refrigerant a cylinder may hold, set to leave vapour space for expansion. Overfilling risks hydraulic pressure rise, valve damage and cylinder rupture when warmed.

Related: Tare weight, Recovery cylinder, Hydrostatic pressure test
Non-condensable gas

Air or nitrogen trapped in a system or cylinder that does not liquefy at normal condenser conditions. It raises discharge pressure, reduces cooling and must be purged from recovery equipment or eliminated by correct evacuation.

Related: Recovery cylinder, Vacuum
System diagnosis

A structured process of gathering symptoms, comparing measured pressures and temperatures with specifications and isolating the faulty component before repair. It relies on logical testing rather than parts substitution.

Related: Pressure-temperature relationship, Leak detection, Performance test
Pressure-temperature relationship

The fixed link between a refrigerant's saturation pressure and temperature, shown on a PT chart. Comparing measured pressure with expected temperature reveals undercharge, restriction or condenser problems.

Related: Superheat, Subcooling, System diagnosis
Superheat

The temperature of refrigerant vapour above its saturation temperature at the same pressure. Measured at the evaporator outlet, it confirms the evaporator is fully boiled and the charge is adequate.

Related: Subcooling, Pressure-temperature relationship, Expansion valve
Subcooling

The temperature of liquid refrigerant below its saturation temperature at the same pressure. Measured at the condenser outlet, it indicates liquid seal and charge level in the high side.

Related: Superheat, Condenser, Pressure-temperature relationship
Leak detection

Finding the point where refrigerant escapes using electronic detectors, UV dye, soap solution or pressure testing with dry nitrogen. It must precede evacuation and charging to avoid repeat failure.

Related: Electronic leak detector, UV dye trace, System diagnosis
Electronic leak detector

An instrument that senses refrigerant concentration in air and alarms near a leak. It must be calibrated, used with the correct refrigerant setting and checked against a known reference before testing.

Related: Leak detection, UV dye trace
UV dye trace

A method where fluorescent dye is added to the system and leaks glow under ultraviolet light. It locates slow leaks but requires cleaning of residue and correct dye compatibility.

Related: Leak detection, Electronic leak detector
Expansion valve

A metering device that throttles liquid refrigerant into the evaporator and regulates flow to maintain superheat. A sticking or incorrectly set valve causes poor cooling or evaporator icing.

Related: Superheat, Orifice tube, Evaporator
Orifice tube

A fixed restriction that meters refrigerant flow in many mobile systems, often with a filter screen. It cannot adjust, so charge level and condenser performance strongly affect cooling.

Related: Expansion valve, Subcooling
Condenser

The heat exchanger that rejects heat from compressed refrigerant vapour to outside air, causing it to condense to liquid. Airflow blockage or fan failure raises high-side pressure and reduces cooling.

Related: Subcooling, Receiver-drier
Evaporator

The heat exchanger inside the cabin where liquid refrigerant boils and absorbs heat from air. It also dehumidifies, and its surface must be kept clean and drained to avoid odours and icing.

Related: Superheat, Expansion valve, Cabin air filter
Receiver-drier

A high-side reservoir that stores liquid refrigerant and holds desiccant to remove moisture. A saturated drier restricts flow and must be replaced whenever the system is opened.

Related: Condenser, Moisture indicator, Evacuation
Evacuation

Removing air and moisture from a system with a vacuum pump to a specified deep vacuum, held to confirm no leaks. It is essential before charging and protects the compressor and expansion device.

Related: Vacuum, Micron gauge, Moisture indicator
Vacuum

Pressure below atmospheric, measured in microns or millibars, used to boil off moisture and prove system tightness. A vacuum that rises after isolation indicates a leak or trapped moisture.

Related: Evacuation, Micron gauge, Non-condensable gas
Micron gauge

An electronic instrument measuring deep vacuum in microns, far more precisely than manifold gauges. It confirms evacuation is complete and that the system holds vacuum.

Related: Vacuum, Evacuation
Moisture indicator

A sight glass element that changes colour to show water content in refrigerant or oil. It warns of moisture ingress that could form acids and damage the system.

Related: Receiver-drier, Evacuation, Recycling
Performance test

A controlled check of vent temperature, pressures and airflow against manufacturer specifications at set ambient and engine conditions. It confirms the repair restored cooling before handover.

Related: System diagnosis, Superheat, Commissioning
Commissioning

The final stage of setting a repaired system into service, including charge verification, control calibration, function checks and recording results for the customer and workshop records.

Related: Performance test, Service record
Compressor clutch

An electromagnetic coupling that engages the compressor pulley with the drive shaft on command from the control module. It protects the belt and allows the system to cycle.

Related: Pressure switch, ECU fault code
Pressure switch

A sensor that opens or closes circuits at set refrigerant pressures to protect the compressor and fans. Three-level types signal low charge, fan control and overpressure cut-out.

Related: Compressor clutch, ECU fault code
ECU fault code

A stored diagnostic trouble code set by the air conditioning or body control module when a circuit or sensor reads out of range. It guides testing with a scan tool and wiring diagram.

Related: Pressure switch, Compressor clutch, System diagnosis
Cabin air filter

A pleated filter that traps dust, pollen and particles from air entering the HVAC case. A clogged filter reduces airflow, causes window misting and stresses the blower.

Related: Evaporator, Blower motor
Blower motor

An electric fan that moves air through the HVAC case, often controlled by a resistor pack or PWM module. Speed faults usually trace to the resistor, module or motor brushes.

Related: Cabin air filter, Air distribution door
Air distribution door

A movable flap that directs conditioned air to windscreen, face or foot outlets. Actuator or calibration faults leave air stuck at one outlet or prevent defrost selection.

Related: Blower motor, Cabin air filter
Alternative refrigerant

A refrigerant other than the original R-134a or R-1234yf, such as R-744 carbon dioxide or blends. It requires different equipment, pressures and safety procedures and must never be mixed with the original charge.

Related: Global warming potential (GWP), Refrigerant identifier, R-1234yf
R-1234yf

A low-GWP hydrofluoroolefin refrigerant used in newer vehicles, classified as mildly flammable (A2L). It needs dedicated service equipment, leak detection and ignition-source precautions.

Related: Alternative refrigerant, A2L flammability, Refrigerant identifier
A2L flammability

A safety classification for mildly flammable refrigerants with low burning velocity. Workshops must control ignition sources, ventilate, and use equipment rated for A2L when servicing such systems.

Related: R-1234yf, Alternative refrigerant
Refrigerant identifier

A device that analyses a gas sample to confirm refrigerant type and detect contamination or mixed gases. It prevents cross-contamination of recovery cylinders and service equipment.

Related: Alternative refrigerant, Recovery cylinder
Service record

Documentation of work performed, refrigerant type and quantity recovered or charged, leak checks and test results. It supports traceability, warranty claims and regulatory compliance.

Related: Commissioning, F-gas regulation
Customer handover

Explaining the fault found, work done, costs and any advice on use or follow-up to the vehicle owner. Clear, jargon-free communication prevents disputes and builds trust.

Related: Service record, Commissioning
Workshop supervision

Planning and overseeing technicians' work so that safety rules, equipment use and quality standards are met. It includes allocating jobs, checking competence and maintaining records.

Related: Service record, Personal protective equipment (PPE)