NVQ L4 Automobile AC Technician study plan
NVQ L4 Automobile AC Technician · Give each week a clear focus.
8 weeks · About 7 hours per week
Health, Safety and Environmental Practice in Refrigerant Handling & System Diagnosis, Leak Detection and Fault Finding
Map every hazard in a refrigerant-handling bay (asphyxiation, frostbite, high-pressure rupture, oil mist, ignition of A2L/A3 refrigerants) and state the control measure for each
Demonstrate donning and doffing of gloves, face shield and eye protection, and explain why liquid refrigerant contact causes instant cryogenic burns
Explain the legal and environmental duties for refrigerant containment, leakage reporting and safe disposal under the applicable F-gas/ODS framework in your jurisdiction, without quoting unverified figures
Set up and verify a calibrated electronic leak detector and an oxygen monitor before work, and record the pre-use checks
Produce a one-page risk assessment for a recovery-and-recharge job on a vehicle using R-1234yf
Your checkpoint
A signed, one-page job risk assessment plus a completed pre-use equipment checklist covering PPE, leak detector, oxygen monitor and ventilation
Refrigerant Recovery, Recycling, Reclamation and Cylinder Management & Health, Safety and Environmental Practice in Refrigerant Handling
Identify refrigerant cylinder types, valve fittings and colour/identifier conventions, and explain why cylinder identification must never rely on colour alone
Perform liquid-vapour discrimination: decide when to recover as liquid versus vapour and justify the choice for a given system charge
Operate a recovery machine to pull a system down to the target residual pressure, and explain why the machine must never be used to evacuate a system to vacuum
Weigh a cylinder before and after recovery and reconcile the recovered mass against the recorded charge, explaining any shortfall
Describe safe cylinder filling limits, hydrostatic test/requalification intervals and correct storage segregation for flammable refrigerants
Your checkpoint
A recovery log for one complete job showing start and end cylinder mass, recovered mass, residual system pressure and a written reconciliation of any discrepancy
Refrigerant Recovery, Recycling, Reclamation and Cylinder Management & Alternative Refrigerants and Emerging Mobile AC Technologies
Distinguish recovery, recycling and reclamation by what each process removes and which standard governs the output
Explain why recycled refrigerant cannot be returned to a system owned by another party and when reclaimed refrigerant with documented analysis is required
Compare R-134a, R-1234yf and R-744 on GWP, flammability class, operating pressure and oil compatibility, and state one servicing consequence of each
List the additional controls required when servicing an A2L system: ignition-source exclusion, ventilation, leak detection and charge-size awareness
Explain why R-744 systems need different recovery equipment and pressure ratings than R-134a systems
Your checkpoint
A comparison table of at least four refrigerants covering GWP class, safety group, typical high-side pressure band, lubricant and the specific equipment change each demands
System Diagnosis, Leak Detection and Fault Finding & Evacuation, Charging, Performance Testing and Commissioning
Interpret a pressure-temperature chart to convert measured suction and discharge pressures into saturation temperatures and calculate superheat and subcooling
Diagnose undercharge, overcharge, restricted expansion device, weak compressor and condenser airflow fault from a pressure/temperature/sight-glass pattern
Perform a structured leak search: electronic detector sweep, UV dye and nitrogen pressure test, and explain the limits of each method
Carry out an evacuation to a held vacuum with a micron gauge, and explain why a rising vacuum indicates moisture or a leak
Charge by mass using scales and verify charge against manufacturer specification rather than gauge readings alone
Your checkpoint
A diagnostic worksheet for one simulated or real fault showing recorded pressures, saturation temperatures, calculated superheat and subcooling, the diagnosis and the verification reading after repair
Repair, Component Replacement and System Reassembly & System Diagnosis, Leak Detection and Fault Finding
Follow the correct sequence to isolate, recover, open, reseal and requalify a system during compressor or condenser replacement
Select and fit the correct O-ring and seal material for the refrigerant and lubricant in use, and explain the consequences of a wrong material choice
Torque fasteners to specification and explain why over-torquing flare and block fittings causes leaks
Inspect and flush or replace a receiver-drier or accumulator after system opening, and justify the decision
Verify oil quantity and viscosity after component replacement and record the adjustment made
Your checkpoint
A component replacement record for one job listing every seal, torque value, oil adjustment and post-repair leak and performance check
Electrical and Electronic Control Systems for Mobile Air Conditioning & Evacuation, Charging, Performance Testing and Commissioning
Read a mobile AC wiring diagram and trace the compressor clutch, blower, pressure switch and relay circuits end to end
Measure voltage drop and current draw on the clutch and blower circuits and interpret the results against expected values
Test a pressure transducer and a thermistor, and distinguish a sensor fault from a wiring fault
Explain how the PCM/BCM controls compressor engagement, including cut-out conditions and CAN bus communication faults
Run a performance test: record vent temperature, ambient temperature, humidity and pressures, and compare against the expected performance envelope
Your checkpoint
A circuit trace and measurement sheet for one control fault, showing expected versus measured values at each test point and the component found at fault
HVAC Air Distribution, Cabin Comfort and Air Quality & Customer Communication, Records and Workshop Supervision
Diagnose a cabin comfort complaint by separating airflow, temperature, humidity and air-quality causes
Inspect and test blend door actuators, mode doors and the cabin filter, and explain the effect of a stuck blend door on vent temperature
Explain the purpose of the evaporator drain and describe the symptoms and health implications of a blocked drain
Write a customer-facing explanation of a repair in plain language covering what failed, what was done and what the customer should watch for
Complete a job record that would satisfy an audit: refrigerant type and mass, recovered and charged amounts, leak test result and technician identification
Your checkpoint
One complete auditable job file plus a plain-language customer handover note for the same job
Customer Communication, Records and Workshop Supervision & Health, Safety and Environmental Practice in Refrigerant Handling & Alternative Refrigerants and Emerging Mobile AC Technologies
Supervise a simulated job end to end: brief the task, allocate roles, check PPE and equipment, and sign off the work
Audit a peer's job record against the required fields and give two specific corrective actions
Explain the workshop's duty to train and monitor staff on refrigerant handling and to keep equipment calibration current
Re-test the two lowest-scoring domains from earlier weeks and close the identified gaps
Summarise the emerging technology changes likely to affect servicing practice and state how you will keep your knowledge current
Your checkpoint
A supervision pack containing a completed job sign-off, a peer audit with corrective actions and a written gap-closure summary for the two weakest domains
Milestones
Week 2: Can complete a recovery unaided, with a reconciled mass log and no cylinder overfill, and can explain the legal duty for containment
Week 4: Can calculate superheat and subcooling from live readings and correctly diagnose at least three of four fault scenarios on a worksheet
Week 6: Can trace a compressor control circuit on a diagram and locate an injected electrical fault within 20 minutes using measurements only
Week 8: Scores at least 75% on a self-set mixed mock covering all nine domains, with no domain below 60%, and has a complete auditable job file