Morocco Equipment Technician study materials
Morocco Equipment Technician study resources

Morocco Equipment Technician key terms

Morocco Equipment Technician · Get comfortable with the vocabulary.

Lockout/Tagout (LOTO)

A formal procedure in which every energy source feeding a machine is isolated, locked and tagged by the person working on it, so the equipment cannot be re-energised or started until that person removes their own lock.

Related: Zero Energy State, Risk Assessment
Zero Energy State

The verified condition in which all hazardous energy, including electrical, mechanical, hydraulic, pneumatic, thermal and stored energy, has been isolated, dissipated or restrained before maintenance work begins.

Related: Lockout/Tagout (LOTO), Stored Energy, Risk Assessment
Risk Assessment

A structured examination of a task or workplace that identifies hazards, estimates the likelihood and severity of harm, and records the controls needed to reduce risk to an acceptable level before work starts.

Related: Lockout/Tagout (LOTO), Personal Protective Equipment (PPE), Permit to Work
Permit to Work

A signed authorisation that defines the scope, hazards and precautions for a non-routine or high-risk job, and confirms that isolation, gas testing or fire watch conditions are met before work proceeds.

Related: Risk Assessment, Lockout/Tagout (LOTO)
Personal Protective Equipment (PPE)

Wearable or handheld protection such as gloves, eye shields, arc-rated clothing, helmets and hearing protection, selected from the assessed hazard and inspected before each use as the last line of defence.

Related: Risk Assessment, Arc Flash
Arc Flash

A rapid release of energy caused by an electrical fault through air, producing intense heat, light, pressure and molten metal; it defines the boundary distances and protective clothing required before energised work is permitted.

Related: Personal Protective Equipment (PPE), Lockout/Tagout (LOTO), Voltage Verification
Voltage Verification

The practice of proving a tester on a known live source, testing the isolated conductors to confirm absence of voltage, then re-proving the tester, so a dead circuit is confirmed rather than assumed.

Related: Lockout/Tagout (LOTO), Zero Energy State, Multimeter
Ohm's Law

The relationship stating that voltage equals current multiplied by resistance; it lets a technician predict how a circuit will behave and calculate an unknown value from the other two measured quantities.

Related: Multimeter, Series and Parallel Circuits, Power Factor
Three-Phase Power

An AC supply using three conductors whose voltages are offset by 120 electrical degrees, giving constant power delivery and allowing motors to produce a rotating magnetic field without auxiliary starting windings.

Related: Phase Rotation, Star-Delta Connection, Power Factor
Phase Rotation

The order in which the three supply voltages reach their peak; it must match the motor's expected direction, because reversing any two supply conductors reverses rotation and can damage driven equipment.

Related: Three-Phase Power, Motor Nameplate
Power Factor

The ratio of real power to apparent power in an AC circuit, ranging from 0 to 1; a low value means more current flows for the same useful work, increasing losses and utility charges.

Related: Ohm's Law, Three-Phase Power, Variable Frequency Drive (VFD)
Star-Delta Connection

A motor starting arrangement where windings run in star for reduced starting current, then switch to delta for full voltage; it requires six winding ends and correct changeover timing to avoid current surges.

Related: Three-Phase Power, Motor Nameplate, Contactor
Contactor

An electromagnetically operated switch used to connect and disconnect a load circuit repeatedly under normal current, controlled by a coil circuit and often interlocked with overload and safety devices.

Related: Overload Relay, Star-Delta Connection, Programmable Logic Controller (PLC)
Overload Relay

A protective device that senses sustained excess motor current, typically through thermal or electronic elements, and opens the control circuit before winding insulation is damaged by overheating.

Related: Contactor, Motor Nameplate, Root Cause Analysis
Variable Frequency Drive (VFD)

An electronic unit that rectifies incoming AC, then inverts it to a controlled voltage and frequency, allowing motor speed and torque to be matched to process demand and reducing starting stress.

Related: Programmable Logic Controller (PLC), Power Factor, Electromagnetic Interference (EMI)
Programmable Logic Controller (PLC)

An industrial computer that reads input signals, executes a stored control program and drives outputs, replacing relay logic and providing timers, interlocks and diagnostic information for machinery.

Related: Contactor, Analog Signal, Human-Machine Interface (HMI)
Analog Signal

A continuously variable electrical signal, commonly 4-20 mA or 0-10 V, whose magnitude represents a measured value such as pressure or temperature; the live zero allows broken wires to be detected.

Related: Calibration, Loop Check, Programmable Logic Controller (PLC)
Calibration

The documented comparison of an instrument's indication against a traceable reference, followed by adjustment so its output matches the true value within stated tolerance across the working range.

Related: Analog Signal, Loop Check, Root Cause Analysis
Loop Check

A verification that every element in an instrument loop, from field sensor through wiring, controller and final element, responds correctly and is labelled consistently with the documentation.

Related: Calibration, Analog Signal, Punch List
Human-Machine Interface (HMI)

The screen and controls through which an operator monitors and commands a machine or process, displaying status, alarms and setpoints while communicating with the controller.

Related: Programmable Logic Controller (PLC), Alarm Prioritisation
Electromagnetic Interference (EMI)

Unwanted electrical noise coupled into signal or power conductors by nearby drives, switching devices or radio sources, causing measurement errors, false trips or communication faults unless shielded and earthed correctly.

Related: Variable Frequency Drive (VFD), Earthing and Bonding, Analog Signal
Earthing and Bonding

The deliberate connection of exposed metalwork and circuit reference points to earth, providing a low-impedance fault path that trips protection and limiting touch voltage and electrical noise.

Related: Electromagnetic Interference (EMI), Arc Flash, Voltage Verification
Multimeter

A portable instrument combining voltage, current, resistance and often continuity measurement, with a category rating that must suit the circuit's fault energy to protect the user.

Related: Voltage Verification, Ohm's Law
Hydraulic Pressure

The force per unit area generated in a confined liquid by a pump or load resistance; it transmits force through the system and is controlled by relief, reducing and directional valves.

Related: Relief Valve, Hydraulic Accumulator, Contamination Control
Relief Valve

A pressure-limiting valve that opens to divert flow to tank when system pressure exceeds its setting, protecting components and personnel from overpressure and confirming pump output has a safe path.

Related: Hydraulic Pressure, Hydraulic Accumulator, Stored Energy
Hydraulic Accumulator

A vessel storing pressurised fluid or gas that smooths pulsation and supplies emergency flow; it retains hazardous stored energy that must be discharged before any work on the circuit.

Related: Stored Energy, Relief Valve, Zero Energy State
Contamination Control

The practices of filtering, sealing and cleanliness that keep particles and water out of hydraulic and pneumatic fluid, since most component failures trace back to contaminated media.

Related: Hydraulic Pressure, Root Cause Analysis, Preventive Maintenance
Pneumatic Valve

A directional or control device that uses compressed air to shift a spool or seat, often with a solenoid pilot and spring return, determining actuator motion and fail-safe position on air loss.

Related: Actuator, Stored Energy, Loop Check
Stored Energy

Energy held after isolation, such as in capacitors, springs, raised loads, accumulators or compressed air lines, which must be released or restrained before work is considered safe.

Related: Zero Energy State, Hydraulic Accumulator, Lockout/Tagout (LOTO)
Alignment

The adjustment of two coupled shafts so their centrelines coincide within stated angular and parallel tolerances, measured with dial indicators or laser systems to prevent vibration and bearing wear.

Related: Soft Foot, Vibration Analysis, Laser Alignment
Laser Alignment

A shaft alignment method using laser emitters and detectors on each shaft to calculate offset and angularity, often displaying live corrections for shims and horizontal movement.

Related: Alignment, Soft Foot
Soft Foot

A condition where a machine foot does not sit flat on its base, so tightening the bolt distorts the frame; it must be corrected before alignment readings are trusted.

Related: Alignment, Vibration Analysis
Vibration Analysis

The measurement and interpretation of machine vibration spectra to detect unbalance, misalignment, looseness and bearing defects, allowing faults to be corrected before failure.

Related: Alignment, Predictive Maintenance, Root Cause Analysis
Predictive Maintenance

Condition-based work scheduled from measured trends such as vibration, temperature, oil analysis or thermography, so intervention happens just before degradation becomes functional failure.

Related: Vibration Analysis, Preventive Maintenance, Thermography
Preventive Maintenance

Planned, time- or usage-based servicing such as lubrication, inspection, cleaning and part replacement, performed to reduce the probability of failure rather than to correct an existing fault.

Related: Predictive Maintenance, Contamination Control, Work Order
Thermography

Infrared imaging of equipment surfaces to reveal abnormal temperature rise from loose connections, friction, blocked cooling or insulation faults, performed safely while the equipment is operating.

Related: Predictive Maintenance, Vibration Analysis, Root Cause Analysis
Root Cause Analysis

A structured investigation, using methods such as five-why or fishbone, that traces a failure past its symptoms to the underlying physical, procedural or design cause so recurrence is prevented.

Related: Failure Mode and Effects Analysis (FMEA), Corrective Action, Vibration Analysis
Failure Mode and Effects Analysis (FMEA)

A team-based review that lists how each component could fail, the effect of that failure, and its severity, occurrence and detection ratings, guiding design and maintenance priorities.

Related: Root Cause Analysis, Risk Assessment
Corrective Action

The change made to equipment, procedure or training that eliminates a confirmed cause of nonconformity, recorded and verified for effectiveness rather than simply repairing the symptom.

Related: Root Cause Analysis, Work Order
Work Order

A controlled document authorising and recording a maintenance task, including scope, permits, parts, labour hours, findings and completion sign-off, forming the equipment history.

Related: Preventive Maintenance, Punch List, Corrective Action
Punch List

A register of outstanding defects and incomplete items identified during installation or commissioning, each with an owner and deadline, closed out before handover to the client.

Related: Loop Check, Commissioning, Work Order
Commissioning

The staged process of checking, energising, testing and proving installed equipment, first without load then under load, until documented performance criteria are met and the plant is accepted.

Related: Loop Check, Punch List, Alignment
Motor Nameplate

The manufacturer's plate stating rated voltage, current, frequency, speed, power, insulation class, duty and connection, which must be read before wiring or replacing a motor.

Related: Three-Phase Power, Overload Relay, Star-Delta Connection
Actuator

A device such as a cylinder, motor or diaphragm that converts hydraulic, pneumatic or electrical energy into mechanical movement to operate a valve, damper or other final element.

Related: Pneumatic Valve, Loop Check
Series and Parallel Circuits

Two ways of connecting loads: in series the same current passes through all and voltages add, while in parallel the same voltage applies to each and currents add.

Related: Ohm's Law, Multimeter
Alarm Prioritisation

The ranking of alarm messages by consequence and urgency so operators can distinguish safety-critical events from routine notifications and avoid alarm flooding.

Related: Human-Machine Interface (HMI), Programmable Logic Controller (PLC)
Technical Documentation

Drawings, datasheets, manuals, procedures and test records that define the installed configuration and allow safe maintenance; revisions must be controlled so field and file agree.

Related: Work Order, Commissioning, Punch List