MA Roofing Contractor flashcards
MA Roofing Contractor · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- 780 CMR
- The Massachusetts State Building Code, which adopts the IBC and IRC with Massachusetts amendments and is enforced statewide by local building officials.
- Two-layer reroof limit
- Code allows a new roof covering over a maximum of one existing layer, for a total of two layers; a third layer requires removal of all existing coverings to the deck.
- Ice barrier extension
- In Massachusetts, a self-adhering waterproofing membrane must extend from the eave edge to at least 24 inches inside the exterior wall line of the heated building.
- 25 percent reroof rule
- When 25 percent or more of a roof is replaced within 12 months, the entire roof must be brought into compliance with current code requirements.
- Minimum steep-slope threshold
- Roof coverings such as asphalt shingles require a minimum slope of 2:12; below that slope, a listed low-slope roof assembly must be used.
- Double underlayment zone
- On slopes from 2:12 to 4:12, asphalt shingles must be installed over two layers of underlayment instead of the single layer required on steeper roofs.
- Standing seam minimum slope
- Standing seam metal roof panels can be installed on slopes lower than through-fastened panels, often as low as 1:12 when the manufacturer's listed assembly permits.
- Built-up roofing plies
- Built-up roofing is a low-slope membrane made of at least two plies of felt or fabric set in bitumen, often surfaced with gravel, and requires a minimum slope around 1:4.
- Sheathing panel edge gap
- Wood structural panel roof sheathing must be spaced about 1/8 inch at panel edges to allow for expansion and prevent buckling.
- Step flashing
- Corrosion-resistant metal flashing installed in steps along a sidewall, with each piece lapped over the shingle course and under the next, to shed water.
- Drip edge placement
- Corrosion-resistant drip edge is installed under the underlayment at eaves and over the underlayment at rakes, directing water away from the fascia.
- Valley flashing width
- Valley flashing must be at least 12 inches wide, or wider per the manufacturer, and is installed over the underlayment beneath the roof covering.
- Roof live load minimum
- The code requires a minimum roof live load of 20 psf for ordinary roofs and 12 psf for certain low-slope roofs, in addition to dead, snow, and wind loads.
- Slope factor formula
- The roof area multiplier equals the square root of 1 plus the rise over run squared; a 6:12 roof has a factor of about 1.118.
- Roof dead load
- The weight of the roof covering and assembly, roughly 2 to 4 psf for asphalt shingles and 6 to 20 psf for tile or slate, must be included in structural design.
- Collar ties and rafter thrust
- Collar ties or ceiling joists tie opposing rafters together to resist the outward thrust that a sloped roof places on the supporting walls.
- Class A roof covering
- A roof covering listed as Class A under ASTM E108 or UL 790 is effective against severe fire exposure and passes a 2-hour fire test.
- Class C roof covering
- A Class C roof covering is effective against light fire exposure and passes only a 10-minute fire test, making it the least fire-resistant class.
- Assembly fire rating
- The fire classification applies to the entire roof assembly, including deck and underlayment, not just the top surface of the covering.
- Occupancy separation
- Fire separation between different occupancies or buildings is governed by 780 CMR Chapters 6 and 7 and depends on occupancy group and construction type.
- Attic vent ratio
- Attic ventilation requires at least 1 square foot of net free vent area per 150 square feet of attic floor area, or 1:300 with a vapor barrier and balanced vents.
- Intake and exhaust balance
- At least 50 percent of the required attic vent area should be intake vents at the soffits, balanced with exhaust vents at the ridge or gables.
- Vent space baffle
- Baffles at the eaves keep insulation at least 1 inch away from the roof sheathing so soffit intake vents remain open and air can flow.
- Air sealing ceiling plane
- Gaps around chimneys, recessed lights, plumbing penetrations, and top plates must be sealed to stop warm moist air from entering the attic and causing condensation.
- Chapter 93A
- Massachusetts consumer protection statute that prohibits unfair or deceptive acts in trade and allows actual damages, multiple damages, and attorney's fees.
- Home improvement contract
- For work over $500, a written contract must list the contractor's name, address, license number, scope, materials, price, payment schedule, and dates.
- Three-day rescission
- Massachusetts gives consumers three business days to cancel certain home solicitation contracts, and the written notice of this right must be provided.
- Construction Supervisor License
- A CSL issued by the BBRS is required to supervise construction, alteration, repair, or demolition above certain thresholds, and must be renewed every two years.
- CSL continuing education
- Licensed construction supervisors must complete 12 hours of approved continuing education per two-year renewal cycle, including code and safety topics.
- Unlicensed practice
- Supervising work that requires a license without holding one is prohibited and subject to fines and cease-and-desist orders from the state.
- OSHA fall protection trigger
- Fall protection is required for construction employees working 6 feet or more above a lower level, under 29 CFR 1926.501.
- Fall arrest anchorage
- Personal fall arrest anchorage must support at least 5,000 pounds per employee, and the system must limit arresting force to 1,800 pounds.