- Design Density
- Related: Hydraulically Most Demanding Area, Design Area
The minimum rate of water application, expressed in gallons per minute per square foot, that must be delivered over the hydraulically most demanding area for a given hazard classification.
- Design Area
- Related: Design Density, Remote Area
The calculated floor area, in square feet, over which sprinkler discharge must be assumed when sizing the system; it may be reduced for certain dry or quick-response configurations.
- Hydraulically Most Demanding Area
- Related: Design Density, Hydraulic Calculation
The specific portion of the sprinkler system that requires the greatest water pressure at the supply to achieve design density, determined by calculation rather than by physical distance alone.
- Hydraulic Calculation
- Related: Hydraulically Most Demanding Area, Safety Margin
A pressure-and-flow analysis of pipe friction loss, elevation change, and fitting losses used to prove the system can deliver the required density at the most remote sprinklers.
- Safety Margin
- Related: Hydraulic Calculation, Water Supply Curve
The extra water supply pressure or flow reserved above the calculated system demand, typically 10 to 20 psi, to account for pipe aging and calculation uncertainty.
- Water Supply Curve
- Related: Flow Test, Safety Margin
A graph of available pressure versus flow at the point of connection, derived from a flow test, against which the system demand curve is plotted to confirm adequacy.
- Hazard Classification
- Related: Design Density, Ordinary Hazard Group 2
The categorization of an occupancy as light, ordinary Group 1 or 2, or extra Group 1 or 2, based on fuel load and combustibility, which sets density, spacing, and protection requirements.
- Ordinary Hazard Group 2
- Related: Hazard Classification, Design Density
A hazard category for occupancies with moderate to substantial fuel loads and moderate combustibility, such as certain mercantile and storage areas, requiring higher density than Group 1.
- K-Factor
- Related: Residual Pressure, Sprinkler Discharge
A discharge coefficient that relates sprinkler flow to pressure, where flow in gallons per minute equals the K-factor times the square root of the pressure in psi.
- Residual Pressure
- Related: Static Pressure, Flow Test
The pressure remaining at a gauge during flowing conditions, used with static pressure and flow to describe available supply and to compute required sprinkler pressure.
- Static Pressure
- Related: Residual Pressure, Flow Test
The pressure measured at a gauge with no water flowing, representing the elevation and supply head component before friction losses occur during discharge.
- Flow Test
- Related: Water Supply Curve, Residual Pressure
A field procedure using hydrants or test valves and pitot readings to establish the static pressure, residual pressure, and corresponding flow available from the public or private water supply.
- Sprinkler Discharge
- Related: K-Factor, Design Density
The volume of water, in gallons per minute, that an individual sprinkler delivers at a stated pressure, determined by its K-factor and the pressure at the head.
- Remote Area
- Related: Design Area, Hydraulically Most Demanding Area
The portion of the system hydraulically farthest from the water supply in terms of pressure demand; often, but not always, the physically most distant sprinklers.
- Quick-Response Sprinkler
- Related: Design Area, Thermal Element
A sprinkler with a fast-acting thermal element, identified by its response time index, that allows design area reduction in some light and ordinary hazard applications.
- Thermal Element
- Related: Temperature Rating, Quick-Response Sprinkler
The heat-sensitive component of a sprinkler, such as a glass bulb or fusible link, that ruptures at its rated temperature to release the water seal.
- Temperature Rating
- Related: Thermal Element, Sprinkler Spacing
The nominal activation temperature marked on a sprinkler, selected to be above expected ceiling temperatures so the head does not operate prematurely.
- Sprinkler Spacing
- Related: Coverage Area, Deflector Distance
The maximum and minimum distances permitted between sprinklers and between sprinklers and walls, governed by hazard classification and ceiling construction.
- Coverage Area
- Related: Sprinkler Spacing, Branch Line
The floor area protected by a single sprinkler, calculated as spacing along the branch line multiplied by spacing between branch lines, and capped by code maximums.
- Deflector Distance
- Related: Sprinkler Spacing, Obstruction
The required clearance between the sprinkler deflector and the ceiling or roof deck, which controls spray pattern development and activation timing.
- Branch Line
- Related: Cross Main, Coverage Area
The pipe that carries water to individual sprinklers or sprigs and connects to a cross main; its size and length affect friction loss and balance.
- Cross Main
- Related: Branch Line, Riser
The main pipe feeding branch lines in a tree or loop arrangement, sized hydraulically and supported at prescribed intervals.
- Riser
- Related: Riser Nipple, Main Drain
The vertical pipe supplying the sprinkler system from the water supply main, typically containing the control valve, check valve, and alarm connections.
- Riser Nipple
- Related: Branch Line, Sway Brace
The vertical pipe connecting a sprinkler to a branch line in exposed piping, subject to length and bracing limitations.
- Sway Brace
- Related: Riser Nipple, Hanger
A structural restraint that resists lateral or longitudinal movement of piping during water surge or seismic activity, installed at specified intervals.
- Hanger
- Related: Sway Brace, Riser
A support that carries the dead weight of sprinkler piping at maximum spacing intervals determined by pipe size and type.
- Obstruction
- Related: Deflector Distance, Sprinkler Spacing
A structural member, duct, or object that blocks sprinkler spray, requiring additional sprinklers or relocation to maintain coverage.
- Main Drain
- Related: Riser, Flow Test
A valve and discharge line at the low point of the system used to drain water and to conduct the main drain flow test that verifies supply adequacy.
- Inspector's Test Valve
- Related: Waterflow Alarm, Main Drain
A valve at the end of the most remote branch line used to simulate a single sprinkler operation and confirm that the alarm activates within the required time.
- Waterflow Alarm
- Related: Inspector's Test Valve, Alarm Valve
A device and notification appliance that signals water movement in the system, required to activate within a specified delay after flow begins.
- Alarm Valve
- Related: Waterflow Alarm, Riser
A check valve that holds system pressure and, when a sprinkler operates, opens to pass water and trigger the alarm circuit.
- Impairment Procedure
- Related: Fire Watch, Main Drain
The documented process of notifying the authority and building occupants, posting signage, and providing a fire watch when a system is out of service.
- Fire Watch
- Related: Impairment Procedure, Alarm Valve
A temporary patrol or monitoring measure required when a sprinkler system is impaired, to detect and report fire until protection is restored.
- Maryland Fire Prevention Code
- Related: Local Amendment, State Fire Marshal
The state-adopted fire code, based on a national model code, that governs sprinkler installation, maintenance, and occupancy requirements throughout Maryland.
- State Fire Marshal
- Related: Maryland Fire Prevention Code, Plan Review
The Maryland official and office with authority to enforce the state fire code, approve plans, and issue orders for sprinkler and life-safety compliance.
- Local Amendment
- Related: Maryland Fire Prevention Code, Permit
A jurisdiction-specific modification to the state fire or building code adopted by a Maryland county or municipality that may impose stricter sprinkler requirements.
- Plan Review
- Related: Permit, Shop Drawings
The formal examination of submitted sprinkler drawings and calculations by the authority having jurisdiction before a permit is issued and installation may begin.
- Shop Drawings
- Related: Plan Review, Hydraulic Calculation
Detailed installation documents showing piping layout, sprinkler locations, hanger details, and hydraulic calculations, submitted for approval prior to construction.
- Permit
- Related: Plan Review, Licensing
The official authorization issued by the authority having jurisdiction allowing sprinkler work to proceed in accordance with approved plans.
- Licensing
- Related: Permit, State Fire Marshal
The state or local credentialing requirement that individuals or firms hold a valid sprinkler contractor or journeyman license to perform regulated work.