Mistake 1

Calculating chlorine dose or CT using the flow rate in the wrong units (e.g., plugging MGD into a formula that expects gpm or L/s) and reporting a dose that is off by a factor of 694 or 1,000.

Maryland treatment math questions mix unit systems. Candidates memorize a formula like Dose (mg/L) = (Feed rate lb/day × 1,000,000) / (Flow MGD × 8.34) but then substitute a flow given in gpm without converting, because under time pressure converting feels like extra steps.

What to do instead

Before substituting numbers, write every given value with its unit on scratch paper, then write the target unit. Convert flows to MGD (gpm ÷ 694.4; L/s ÷ 43.81) and masses to lb/day (kg/day × 2.205) as a separate first line. Sanity-check the result: a chlorine dose should land between roughly 0.5 and 10 mg/L, so an answer of 0.003 or 5,000 means a conversion was missed.

Mistake 2

Treating CT disinfection credit as simply chlorine residual times contact time, ignoring the baffling factor and the required CT table value for the target pathogen and log inactivation.

The CT concept appears in both treatment and compliance contexts, and candidates conflate 'calculated CT' with 'required CT'. They also forget that the actual detention time must be multiplied by a baffling factor (often 0.1–0.7) before multiplying by the residual.

What to do instead

Work the problem in a fixed four-step sequence: (1) actual detention time = volume ÷ flow; (2) effective contact time = actual time × baffling factor; (3) calculated CT = effective time × measured residual (or the residual at the outlet); (4) required CT from the table for the specified temperature, pH, and log credit. Compare calculated to required, then state the ratio as the inactivation achieved. Practice reading a CT table until you can locate the value for a given temperature and pH without hesitation.

Mistake 3

Confusing filter media and backwash parameters - stating that anthracite has a higher specific gravity than sand, or backwashing at the wrong rate or with the wrong expansion target.

The dual-media filter is the classic exam topic, and candidates memorize 'sand on bottom, anthracite on top' without understanding why. Because anthracite (specific gravity about 1.4–1.6) is lighter than sand (about 2.65), it stays on top after backwash; candidates who invert the reasoning then miss questions about backwash expansion, media loss, and mudball formation.

What to do instead

Anchor the fact to the mechanism: backwash water rises, so the lighter, larger-grained media stratifies to the top. Typical backwash produces about 20–25 percent bed expansion at rates around 15–20 gpm/ft² for anthracite and somewhat higher for sand. Link symptoms to causes: media in the wash trough means excessive backwash rate; mudballs and surface cracks mean inadequate backwash or air scour.

Mistake 4

Answering distribution questions about water age and disinfection residual by choosing a treatment-side fix (e.g., 'increase chlorine feed at the plant') instead of the distribution-side action the stem describes.

The domains overlap heavily, and the exam deliberately places a distribution scenario (dead-end main, low residual at a distant tap, storage tank turnover) next to treatment content. Candidates reach for the most familiar control - chlorine feed - rather than the operational fix in the distribution system.

What to do instead

When a stem mentions a location (dead end, distal tap, elevated tank, end of main), restrict your answer set to distribution actions: flushing, looping or eliminating dead ends, adjusting storage tank operating levels to improve turnover, valve and hydrant exercise, and booster chlorination. Reserve plant-side answers for stems that name the treatment process or finished-water quality leaving the plant.

Mistake 5

Misidentifying the Maryland-specific monitoring and reporting obligations - for example, stating that a community system must report total coliform positives to MDE within a generic timeframe, or confusing Tier 1 and Tier 2 public notice deadlines.

Maryland's rules (COMAR 26.04.01 and the federal rules it adopts) set specific reporting and public-notice requirements that differ by contaminant and violation type. Candidates study the federal framework and then guess at state deadlines, or they memorize one deadline and apply it to every situation.

What to do instead

Build a one-page table organized by event: total coliform positive, E. coli positive, nitrate MCL exceedance, lead action level exceedance, Tier 1 (immediate, 24 hours), Tier 2 (30 days), and Tier 3 (annual). For each, record who must be notified (MDE, the public), how, and by when. Verify each entry against the current COMAR text and MDE guidance rather than memory, and flag anything you cannot confirm.

Mistake 6

Confusing the sampling and preservation requirements for bacteriological, nitrate, and lead/copper samples - using the wrong container, missing the hold time, or failing to note that chlorine residual must be measured at the time of total coliform collection.

Sample handling is taught as a checklist, so candidates memorize 'sterile bottle' and apply it to every analyte. Nitrate needs a cooled sample with a hold time measured in days, metals need nitric acid preservation, and total coliform samples require residual measurement at the tap in systems that chlorinate.

What to do instead

Memorize by analyte group: bacteriological - sterile bottle, sodium thiosulfate to neutralize chlorine, cooled, hold time and residual recorded at collection; nitrate/nitrite - cooled, short hold time, no acid; lead and copper - first-draw, stagnation time observed, acid-preserved bottle. Walk through one complete sample event for each group in your head until the container, preservation, and documentation steps are automatic.

Mistake 7

Selecting a source-water protection answer that addresses treatment rather than the source - for example, recommending additional coagulation when the stem describes a turbidity spike after a storm in a surface water supply.

Source water and treatment are adjacent in the exam outline, and turbidity is a treatment parameter as well as a source characteristic. Candidates see 'turbidity' and jump to filter or coagulant answers without noticing the stem is about the reservoir, intake, or watershed.

What to do instead

Read the stem for the location word first: watershed, reservoir, intake, or wellhead means source-water answers (watershed inspection, land-use controls, intake depth adjustment, reservoir management, wellhead protection area, source switching). Only when the stem names the plant process or finished water should you choose treatment controls. Underline the location word before evaluating the options.

Mistake 8

Treating confined-space entry as a same-day routine task - answering that a permit and attendant are needed only for 'deep' spaces, or that atmospheric testing can be done after entry if the entrant feels fine.

Confined-space questions test the permit-required procedure, but candidates who have seen quick entries in the field assume the exam wants the practical shortcut. They also underestimate that a lift station wet well or a clearwell can qualify even when it looks open and shallow.

What to do instead

Apply the definition mechanically: a space is permit-required if it is large enough to enter, has limited entry or exit, and is not designed for continuous occupancy. Then state the full sequence - hazard evaluation, written permit, pre-entry and continuous atmospheric testing for oxygen, flammables, and toxics, ventilation, attendant stationed outside, retrieval system, and communication. Never accept an option that tests after entry or waives the attendant.

Mistake 9

Answering operator certification and reporting questions from general knowledge instead of Maryland's operator classification and continuing-education structure - for example, guessing at class levels or renewal requirements.

Administration content feels like common sense, so candidates skip it during study and then face items on facility classification, operator-in-charge responsibilities, and renewal cycles that have specific state answers. They also confuse federal certification guidance with Maryland's actual program.

What to do instead

Write out Maryland's operator grade structure, the requirement that the system have a designated operator-in-charge at or above the plant's classification, the renewal cycle, and the continuing-education hours per cycle, confirming each against the Maryland Board of Waterworks and Waste System Operators and MDE materials. Treat any figure you cannot verify as a review item rather than a guess.

Mistake 10

Skipping the units and significant-figure check on math answers, then choosing the option that 'looks right' when two choices differ only by a power of ten.

Multiple-choice math items are often built with distractors that reflect a single missed conversion, so the correct and incorrect answers are numerically similar. Candidates who compute quickly and select the first matching number fall for the distractor.

What to do instead

After computing, estimate the answer independently (round flow to 1 MGD equivalent and dose to a whole number) and compare. If two options differ by 10× or 1,000×, identify which conversion each represents before choosing. Carry units through the calculation and cancel them; if the final unit is not the one asked for, the answer is wrong regardless of the number.