CT value
Product of disinfectant residual concentration (mg/L) and contact time (minutes). Required CT depends on disinfectant, pH, temperature, and the log inactivation credit needed.
Log inactivation
A 10-fold reduction in pathogen concentration equals 1 log. Required credit is the target log reduction minus credit for physical removal by filtration.
Turbidity limit
For conventional filtration, individual filter effluent must be ≤ 0.3 NTU in 95% of monthly measurements and never exceed 1 NTU.
Jar test purpose
A bench test that determines the optimum coagulant dose and pH for coagulation and flocculation by simulating treatment conditions on a small sample.
Cryptosporidium control
Chlorine is largely ineffective against Cryptosporidium. Physical filtration plus UV or ozone disinfection is used to achieve required inactivation.
Backwash trigger
A filter is backwashed when head loss reaches the terminal value or effluent turbidity breaks through, using a rate that fluidizes the bed without media loss.
Chlorine MRDL
The maximum residual disinfectant level for chlorine and chloramine is 4.0 mg/L (as Cl2). Distribution residual must generally stay at or above 0.2 mg/L.
Minimum distribution pressure
Design pressure must be at least 20 psi at all points in the distribution system, including during fire flow. Pressure below 20 psi requires a boil-water notice.
Air gap
The only true backflow prevention method: a physical separation between the potable water outlet and the flood-level rim of the receiving vessel.
RPZ assembly
A reduced-pressure-zone backflow preventer that protects against both backpressure and backsiphonage; it is testable and requires annual testing.
Water age
The time water resides in the distribution system. High age causes disinfectant loss, nitrification, and taste/odor problems; reduced by looping and flushing.
Hydrant flow test
A test using a pitot gauge and nozzle coefficient to measure flow and residual pressure, used to estimate available fire flow and system capacity.
Non-revenue water
Water produced minus water billed. It includes leaks, flushing, and unauthorized use; well-run systems typically keep it under 10-15 percent.
Main-sewer separation
Water mains must generally be at least 10 feet horizontally from sewer lines, or use specified vertical separation and casing to prevent contamination.
Total coliform rule
Sets an MCL based on the percentage of positive samples per month and requires repeat sampling within 24 hours of any positive result.
E. coli violation
Presence of E. coli in distribution is a Tier 1 violation requiring public notice within 24 hours and immediate corrective action.
GWUDI
Groundwater under the direct influence of surface water. It must be treated as surface water, requiring filtration and disinfection unless avoidance criteria are met.
Nitrate MCL
The nitrate limit is 10 mg/L as nitrogen. It indicates agricultural or septic contamination and poses a risk to infants (blue baby syndrome).
Turbidity monitoring
Turbidity is measured continuously at each filter, with grab samples for verification. Values above 1 NTU require investigation and corrective action.
Source water assessment
Delineates protection zones around intakes and wells and identifies potential contamination sources to guide wellhead and watershed protection.
Primary versus secondary MCL
Primary MCLs protect health (e.g., nitrate, arsenic, lead action level). Secondary standards address aesthetics such as taste, odor, color, and corrosivity.
Consumer Confidence Report
An annual report delivered to customers by July 1 that lists source water, detected contaminants, and compliance status.
Public notice tiers
Tier 1 (immediate health risk) within 24 hours; Tier 2 within 30 days; Tier 3 within one year. Violations must be reported to the primacy agency.
TTHM and HAA5
Disinfection byproduct MCLs: TTHM 0.080 mg/L and HAA5 0.060 mg/L, evaluated as locational running annual averages.
Lead and copper action level
Lead action level 0.015 mg/L and copper 1.3 mg/L. Exceedance triggers corrosion control, source water treatment, and public education.
Operator certification renewal
Certification requires passing an exam and meeting experience requirements; renewal requires continuing education units (CEUs) and is tracked by the primacy agency.
Confined space testing
Before entry, test for oxygen (19.5-23.5%), flammables (LEL under 10%), H2S (under 10 ppm), and CO (under 35 ppm); use a permit and attendant.
Lockout/tagout
Isolates hazardous energy before maintenance. Apply a personal lock, verify zero energy state, and restore energy only after all workers clear.
Chlorine gas hazard
Chlorine gas is heavier than air and highly toxic. Responders must use SCBA, not a dust mask, and use leak detection and emergency kits.
H2S hazard
Hydrogen sulfide is heavier than air, an asphyxiant, and flammable. It deadens the sense of smell at higher concentrations, so never rely on odor.
Trench protective system
Trenches 5 feet deep or more require a protective system (shoring, shielding, or sloping). Spoil and equipment must be kept at least 2 feet from the edge.
Rate-setting principle
Rates should recover the full cost of service: operation, maintenance, debt service, and reserves. Structures include uniform, increasing block, and seasonal rates.