Maximum stair riser height
The maximum riser height for residential stairs is 7-3/4 inches, with a minimum tread depth of 10 inches, per the Michigan Residential Code.
Guardrail height requirement
Guardrails on decks and porches more than 30 inches above grade must be at least 36 inches high, with baluster spacing that prevents passage of a 4-inch sphere.
Emergency escape opening size
Each sleeping room requires an emergency escape opening with a minimum net clear area of 5.7 square feet, minimum width 20 inches, and minimum height 24 inches.
Smoke alarm placement
Smoke alarms must be installed in each sleeping room, outside each sleeping area, and on each story of the dwelling, including basements, per Michigan code.
Residential builder license scope
A Michigan residential builder license authorizes construction of detached one- and two-family dwellings and attached garages; it does not cover commercial buildings.
Maintenance and alteration license
A Michigan M&A license allows remodeling, repair, and improvement of existing residential structures but does not authorize new home construction.
Right to Cure notice
Michigan law requires a homeowner to provide written notice of a construction defect and allow the builder 60 days to cure before filing a lawsuit.
Construction lien recording deadline
A construction lien must be recorded within 90 days after the last furnishing of labor or materials to the project, per Michigan's Construction Lien Act.
Notice of Furnishing
A subcontractor or supplier must provide a Notice of Furnishing to the owner and general contractor within 20 days after first furnishing labor or materials to preserve lien rights.
Board foot formula
Board feet equals thickness in inches times width in inches times length in feet, divided by 12. Used for estimating lumber quantities.
Concrete volume conversion
Calculate cubic feet by multiplying length, width, and depth in feet, then divide by 27 to convert to cubic yards. Add 5-10% for waste.
Critical path method
The critical path is the longest sequence of dependent activities in a project schedule; any delay on this path delays the entire project completion.
Roof pitch multiplier
To find roof area, divide the horizontal footprint area by the cosine of the roof angle. For a 6/12 pitch, the multiplier is approximately 1.118.
Plan scale conversion
At 1/4 inch equals 1 foot, one inch on the drawing represents 4 feet. At 1/8 inch equals 1 foot, one inch represents 8 feet.
Michigan frost depth
Footings must extend below the local frost line, typically 42 to 48 inches in Michigan's Lower Peninsula, to prevent frost heave.
Air-entrained concrete
Concrete with 5-7% entrained air is required for exterior flatwork in freeze-thaw climates to resist damage from freezing water.
Concrete curing duration
Concrete must be kept moist and above 50 degrees Fahrenheit for at least 7 days to achieve design strength.
Finish grade slope
The ground must slope away from the foundation at least 6 inches within the first 10 feet to direct water away from footings.
Trench protective system
Trenches 5 feet or deeper require a protective system such as sloping, shoring, or a trench box to prevent cave-ins.
Joist notching rules
Notches are allowed only in the outer third of a joist span, with maximum depth of one-sixth the joist depth; holes may not exceed one-third the depth.
Wall bracing requirement
Braced wall panels must be installed at corners and intervals along exterior walls using approved materials such as wood structural panel sheathing.
Stair stringer minimum size
Stair stringers must be at least 2x10 nominal lumber, with no more than one-third of the depth cut at any point, spaced not more than 16 inches on center.
Engineered lumber installation
LVL, LSL, and glulam beams must be installed per manufacturer specifications; field cutting or notching is prohibited unless approved by the manufacturer.
Roof slope for shingles
Asphalt shingles require a minimum roof slope of 2:12; slopes between 2:12 and 4:12 require double underlayment.
Ice barrier membrane
In Michigan, an ice barrier membrane must be installed at eaves, extending at least 24 inches inside the exterior wall line.
Attic insulation R-value
Michigan energy code requires R-49 to R-60 attic insulation depending on climate zone, with local amendments possibly higher.
Roof ventilation ratio
Attic ventilation requires at least 1 square foot of net free vent area per 150 square feet of attic floor area, or 1:300 if balanced.
Window flashing sequence
Flashing must integrate with the weather-resistive barrier in shingle-lap fashion, with sill pan flashing at exterior doors and windows.
OSHA fall protection threshold
Fall protection is required when working 6 feet or more above a lower level in construction, using guardrails, nets, or personal fall arrest.
EPA RRP rule
The Renovation, Repair, and Painting rule requires certified firms and renovators when disturbing painted surfaces in pre-1978 housing; Michigan enforces it.
Asbestos NESHAP notification
Michigan requires inspection and notification before demolition or renovation that may disturb asbestos-containing materials, per EPA NESHAP regulations.
Hazard communication SDS
Safety Data Sheets must be available on site for all chemicals, and employees must be trained on chemical hazards per OSHA Hazard Communication Standard.