MI HVAC study materials
MI HVAC study resources

MI HVAC key terms

MI HVAC · Get comfortable with the vocabulary.

Annual Fuel Utilization Efficiency (AFUE)

A rating that expresses, as a percentage, how much of the energy in fuel a heating appliance converts to usable heat over a full heating season. The rest is lost up the flue or as jacket loss.

Related: Steady-State Efficiency, Combustion Efficiency
Steady-State Efficiency

The efficiency measured while an appliance runs at stable operating conditions, without accounting for on-off cycling, warm-up, or standby losses. It is always equal to or higher than seasonal efficiency.

Related: Annual Fuel Utilization Efficiency (AFUE), Combustion Efficiency
Delta-T (Temperature Difference)

The difference between entering and leaving air temperature across a coil, furnace, or other component. It is used to verify airflow and equipment performance against the manufacturer's approved range.

Related: Temperature Rise, External Static Pressure
Temperature Rise

The increase in air temperature as it passes through a furnace, calculated as supply air temperature minus return air temperature. It must fall within the range on the rating plate.

Related: Delta-T (Temperature Difference), Airflow (CFM)
Condensing Furnace

A high-efficiency gas furnace that extracts latent heat by cooling flue gases below their dew point, producing condensate. It typically achieves AFUE above 90 percent and uses PVC or CPVC venting.

Related: Annual Fuel Utilization Efficiency (AFUE), Latent Heat
Latent Heat

Heat energy absorbed or released during a change of state, such as water vapor condensing to liquid, with no change in temperature. It is the energy recovered by condensing furnaces and released by evaporating coils.

Related: Condensing Furnace, Sensible Heat
Sensible Heat

Heat that changes the temperature of a substance without changing its state. In air conditioning, sensible load is the portion of the load that lowers dry-bulb temperature.

Related: Latent Heat, Sensible Heat Ratio (SHR)
Sensible Heat Ratio (SHR)

The ratio of sensible heat removal to total heat removal for a coil or space. A low ratio means a large share of capacity goes to dehumidification rather than temperature drop.

Related: Sensible Heat, Latent Heat
Superheat

The number of degrees a refrigerant vapor is above its saturation temperature at a given pressure. Measured at the evaporator outlet, it verifies the expansion valve is feeding the coil properly.

Related: Subcooling, TXV (Thermostatic Expansion Valve)
Subcooling

The number of degrees a liquid refrigerant is below its saturation temperature at a given pressure. Measured at the condenser outlet, it indicates how much liquid is stacked in the condenser.

Related: Superheat, TXV (Thermostatic Expansion Valve)
TXV (Thermostatic Expansion Valve)

A metering device that regulates refrigerant flow into the evaporator by sensing suction line temperature and pressure, maintaining a set superheat as load changes.

Related: Superheat, Subcooling
Refrigerant Glide

The temperature change that occurs while a zeotropic refrigerant blend boils or condenses at a constant pressure. Because components vaporize at different temperatures, charging and leak repair require care.

Related: Superheat, Subcooling
External Static Pressure

The resistance to airflow measured at the blower outlet and return inlet, excluding the internal resistance of the appliance itself. It is used with a fan table to determine delivered airflow.

Related: Airflow (CFM), Delta-T (Temperature Difference)
Airflow (CFM)

The volume of air moved per minute, in cubic feet. Proper airflow is required for correct heating temperature rise, cooling capacity, and equipment longevity.

Related: External Static Pressure, Temperature Rise
Return Air

Air drawn back from the conditioned space to the equipment for reconditioning. Undersized return ducting is a common cause of high static pressure and low airflow.

Related: Supply Air, External Static Pressure
Supply Air

Conditioned air delivered from the equipment to the occupied space through the supply duct system and registers.

Related: Return Air, Register
Register

A grille with an integral damper or deflector that covers a duct opening and directs supply or return air into or out of a room.

Related: Return Air, Supply Air
Manual J

The accepted industry method for calculating residential heating and cooling loads from envelope, orientation, occupancy, and climate data. Michigan sizing must follow it rather than rules of thumb.

Related: Manual S, Manual D, Design Temperature
Manual S

The industry procedure for selecting equipment that matches the calculated load, accounting for the structure's actual sensible and latent capacities at design conditions.

Related: Manual J, Sensible Heat Ratio (SHR)
Manual D

The industry method for sizing duct systems based on available static pressure, equivalent lengths, and friction rate so that each room receives its design airflow.

Related: Manual J, External Static Pressure
Design Temperature

The outdoor and indoor conditions used for sizing equipment, selected so the system meets the load during severe but not record weather. Michigan winter design values are well below zero in many locations.

Related: Manual J, Degree Day
Degree Day

A measure of heating or cooling demand based on how far the average daily temperature falls below or rises above a base temperature. It is used for estimating seasonal fuel use and cost.

Related: Design Temperature, Annual Fuel Utilization Efficiency (AFUE)
Two-Stage Thermostat

A control that energizes first-stage heating or cooling for normal loads and calls second stage only when the first cannot satisfy demand, improving comfort and efficiency.

Related: Anticipator, Setback
Anticipator

A small heater in a mechanical thermostat that warms the sensing element slightly ahead of the setpoint so the system shuts down before overshooting the room temperature.

Related: Two-Stage Thermostat, Setback
Setback

A programmed reduction in heating setpoint or increase in cooling setpoint during unoccupied hours to save energy. Recovery must be timed so comfort returns when the space is occupied.

Related: Two-Stage Thermostat, Degree Day
Limit Switch

A safety control that opens the burner circuit when the heat exchanger or plenum exceeds a safe temperature, usually caused by restricted airflow.

Related: Flame Rectification, High-Limit Switch
High-Limit Switch

A temperature-actuated safety device set to open at a maximum safe plenum or bonnet temperature. It protects the heat exchanger and is a required safety control on forced-air furnaces.

Related: Limit Switch, Flame Rectification
Flame Rectification

The method by which a flame-sensing control confirms a burner flame by detecting current flowing through the flame from an energized electrode to ground. Loss of flame signal shuts off gas.

Related: Thermocouple, Limit Switch
Thermocouple

A device made of two dissimilar metals that generates a small voltage when heated, used in standing-pilot systems to hold the gas valve open and prove the pilot flame.

Related: Flame Rectification, Thermopile
Thermopile

A group of thermocouples connected in series that produces enough voltage to operate a millivolt gas valve or control circuit without external power.

Related: Thermocouple, Flame Rectification
Ground Fault Circuit Interrupter (GFCI)

A device that interrupts power when it detects a small imbalance between hot and neutral conductors, protecting people from electric shock in wet or damp locations.

Related: Equipment Grounding, Lockout/Tagout
Equipment Grounding

The intentional connection of non-current-carrying metal parts to earth through a grounding conductor, providing a low-impedance path that clears faults and protects users.

Related: Ground Fault Circuit Interrupter (GFCI), Lockout/Tagout
Lockout/Tagout

A safety procedure in which energy sources are isolated, locked, and tagged before service work so equipment cannot be re-energized by another worker.

Related: Ground Fault Circuit Interrupter (GFCI), Equipment Grounding
BTU (British Thermal Unit)

The amount of heat needed to raise one pound of water one degree Fahrenheit. It is the standard unit for expressing heating and cooling capacity in North America.

Related: Sensible Heat, Manual J
Duct Static Pressure

The outward push of air against duct walls, measured in inches of water column. Supply and return static readings together reveal restriction in the air distribution system.

Related: External Static Pressure, Airflow (CFM)
Barometric Draft Damper

A hinged plate installed in a vent connector that opens to admit room air and stabilize draft, preventing excessive draft from pulling heat up the chimney.

Related: Draft Hood, Combustion Air
Draft Hood

A device on a natural-draft appliance that relieves flue gas spillage and maintains stable draft by mixing room air with flue products before they enter the vent.

Related: Barometric Draft Damper, Combustion Air
Combustion Air

The air supplied to a burner for complete burning of fuel. In tight modern homes it must be brought in from outdoors in adequate quantity to prevent spillage and carbon monoxide.

Related: Draft Hood, Carbon Monoxide (CO)
Carbon Monoxide (CO)

A colorless, odorless gas produced by incomplete combustion. It is a serious health hazard and must be tested for during service and addressed with proper venting and ventilation.

Related: Combustion Air, Draft Hood
Sediment Trap

A short, capped drop leg installed in the gas piping near the appliance to collect dirt, scale, and debris before it reaches the controls.

Related: Gas Pressure Regulator, Manifold Pressure
Manifold Pressure

The gas pressure delivered to the burner orifices, measured with a manometer and set to the value on the rating plate for correct input and combustion.

Related: Gas Pressure Regulator, Sediment Trap
Gas Pressure Regulator

A device that reduces incoming gas pressure to a stable, lower delivery pressure for the appliance and maintains it as supply pressure or load varies.

Related: Manifold Pressure, Sediment Trap
Michigan Mechanical Code

The state-adopted code governing installation, alteration, and inspection of heating, ventilating, and air-conditioning systems in Michigan, enforced by local code officials.

Related: Mechanical Permit, Mechanical Inspector
Mechanical Permit

The authorization a code authority issues before installing or altering regulated HVAC equipment. Work without a required permit can result in failed inspections and penalties.

Related: Michigan Mechanical Code, Mechanical Inspector
Mechanical Inspector

The code official who inspects permitted mechanical work at required stages and approves or rejects it based on compliance with the adopted mechanical code.

Related: Mechanical Permit, Michigan Mechanical Code
Change Order

A written agreement that modifies the scope, price, or schedule of a contracted job after the original contract is signed, authorized by the customer before work proceeds.

Related: Estimate, Punch List
Estimate

A documented projection of labor, material, equipment, and overhead costs used to price a job and establish a profitable selling price.

Related: Change Order, Overhead and Profit
Overhead and Profit

The portion of a selling price that covers fixed business costs such as insurance, vehicles, and administration, plus the return earned on the work performed.

Related: Estimate, Change Order
Punch List

A written list of incomplete or deficient items identified near the end of a project that the contractor must correct before final acceptance and final payment.

Related: Change Order, Estimate