MI Plumber flashcards
MI Plumber · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Drainage Fixture Unit
- A unit value assigned to a fixture representing its probable rate of discharge into the drainage system, with one fixture unit equal to approximately 1 gallon per minute.
- Building Drain
- The lowest piping of a drainage system that receives soil, waste, and other drainage inside the building walls and conveys it to the building sewer, ending 30 inches outside the wall.
- Approved
- Accepted by the code official as meeting the requirements of the plumbing code, often evidenced by listing or labeling by an approved third-party testing agency.
- Slope for Small Drainage Pipe
- Horizontal drainage pipe 2-1/2 inches and smaller must slope at 1/4 inch per foot; pipe 3 inches and larger may slope at 1/8 inch per foot.
- Sanitary Tee
- A drainage fitting that connects a horizontal branch to a vertical stack and directs flow downward with the stack, used only where the branch turns downward.
- Long-Sweep Bend
- A 90-degree drainage fitting with an extended sweep radius, used where a horizontal drainage line changes direction to reduce turbulence and prevent clogging.
- Cleanout Requirements
- Cleanouts are required at the upper end of horizontal drains, at the base of stacks, and within 5 feet of the building sewer, and openings must stay accessible and gas-tight.
- Trap Arm Length
- The horizontal distance from a trap weir to its vent, limited by pipe size and slope; for example, a 2-inch trap arm may not exceed 8 feet at 1/4 inch per foot.
- Dry Vent
- A vent carrying only air that must rise vertically, or at no more than 45 degrees from vertical, until it reaches 6 inches above the fixture flood level rim.
- Vent Terminal Height
- A vent stack must extend at least 6 inches above the roof surface, or 7 feet where the roof is used for purposes other than weather protection.
- Wet Vent
- A pipe that serves as both the drain for one fixture and the vent for another; limited to fixtures on the same floor and sized per code tables.
- Residual Water Pressure
- The minimum flowing pressure required at fixture outlets, generally 8 psi; static pressure above 80 psi requires a pressure reducing valve on the system.
- Pressure Reducing Valve
- A device installed on the water service where static pressure exceeds 80 psi to reduce it to a safe level, with provisions for thermal expansion.
- Air Gap Backflow Prevention
- The unobstructed vertical distance between a water supply outlet and the flood level rim of the fixture it serves, providing the highest degree of backflow protection.
- Water Closet Clearance
- A water closet must be at least 15 inches from its centerline to any side wall and have at least 21 inches of clear space in front of the bowl.
- Shower Receptor Minimum Size
- A shower compartment must measure at least 30 inches by 30 inches inside, have a finished curb, and drain through a minimum 2-inch trapped drain.
- Gravity Water Closet Flush Volume
- Storage-type water closets are limited to 1.6 gallons per flush by federal efficiency standards, with several states requiring 1.28 gallons per flush.
- Trap Seal Depth
- The vertical distance between the trap weir and the top of the trap dip, required to be at least 2 inches and not more than 4 inches.
- Grease Interceptor
- A receptacle installed to intercept fats, oils, and grease from food service fixtures before discharge, sized by code formulas and requiring periodic pumping and maintenance.
- Prohibited Traps
- S-traps, bell traps, crown vents, traps with moving parts, and traps for fixtures with integral traps such as water closets are prohibited by the plumbing code.
- Secondary Roof Drain
- On a roof with a parapet that uses roof drains, a secondary drain or scupper must be installed at least 2 inches above the primary drain to handle overflow.
- Roof Drain Sizing Basis
- Roof drain and leader sizes are chosen from code tables using the roof area served and the 100-year, one-hour rainfall rate for the location.
- Storm Sewer Separation
- Storm drainage must be collected and conveyed separately from sanitary drainage unless the authority having jurisdiction specifically approves a combined sewer connection.
- Offset Travel Multiplier 45 Degrees
- For a 45-degree offset, travel equals the offset dimension multiplied by 1.414, and the offset equals the travel multiplied by 0.707.
- Head Pressure Conversion
- One pound per square inch equals 2.31 feet of water column, so a column 10 feet high produces about 4.33 psi at its base.
- Rainfall to Gallons Per Minute
- Roof runoff in gallons per minute equals the roof area in square feet multiplied by the rainfall rate in inches per hour and by 0.0104.
- Bathroom Group Fixture Units
- A bathroom group containing a water closet, a lavatory, and a bathtub or shower is rated at 6 drainage fixture units for sizing purposes.
- Trench Protective System Threshold
- Excavations 5 feet deep or more require a protective system such as sloping, shoring, or a trench box, unless the excavation is made entirely in stable rock.
- Ladder Extension Above Landing
- Portable ladders must extend at least 3 feet above the landing and be set with the base one-quarter of the working height away from the wall.
- Sediment Trap
- A drip leg installed at the appliance connection that collects dirt, pipe scale, and debris before it can enter and damage the gas controls.
- Gas Piping Bonding
- Fuel gas piping must be made electrically continuous and bonded to the grounding electrode system of the premises wiring to prevent dangerous arcing.
- Appliance Connector Length
- A flexible gas appliance connector may not exceed 6 feet in length and must not pass through walls, floors, ceilings, or concealed spaces.