MI Water Operator study materials
MI Water Operator study resources

MI Water Operator flashcards

MI Water Operator · Build recall with a focused review session.

32 cards. Read the term and the definition here. The deck at the top of this page is optional.

CT value
Product of disinfectant residual concentration in mg/L and contact time in minutes; used to demonstrate log inactivation of pathogens.
Jar test
Laboratory procedure that determines optimal coagulant dose and pH by simulating coagulation, flocculation, and settling in beakers.
Breakpoint chlorination
Point where added chlorine satisfies demand and free chlorine residual begins increasing; beyond it, free chlorine persists.
Filter backwash
Reverse flow through filter media to remove trapped particles; triggered by head loss, turbidity breakthrough, or run time.
Turbidity limit
Michigan conventional filtration requires ≤0.3 NTU in 95% of monthly samples and never above 1 NTU.
Schmutzdecke
Biological layer on slow sand filter surface that removes particles and pathogens; must be protected and periodically scraped.
Fluoride MCL
Primary maximum contaminant level is 4.0 mg/L; secondary standard is 2.0 mg/L; optimal dose typically 0.7 mg/L.
Chlorine demand
Difference between chlorine dose and residual after contact time; reflects consumption by organics, iron, manganese, ammonia.
Minimum distribution pressure
Twenty psi must be maintained under all conditions; normal operating pressure is typically 40 to 80 psi.
Coliform MCL
For systems collecting fewer than 40 samples monthly, more than one total coliform-positive sample triggers the MCL.
TTHM MCL
Stage 2 DBPR limits total trihalomethanes to 80 µg/L as a locational running annual average.
Air gap
Highest-rated backflow prevention method; a physical separation between the potable water supply and a potential contaminant source, with no submerged outlet.
Lead action level
Michigan's 90th-percentile lead action level is 12 ppb, stricter than the federal 15 ppb; exceeding it triggers corrosion control and public education.
Water age
Time water spends in the distribution system; high water age raises disinfection byproduct formation and lowers disinfectant residual.
Hydrant flow test
Measures available flow and pressure at hydrants to evaluate water main capacity, fire protection, and areas needing flushing or rehabilitation.
Specific capacity
Well yield in gallons per minute divided by drawdown in feet; indicates well efficiency and aquifer productivity.
Drawdown
Difference between the static water level and the pumping water level in a well while it is being pumped.
Sanitary well cap
Vermin-proof cap with gasket that seals the casing top and prevents surface water and debris entry.
Wellhead protection area
Land surface around a well where contaminants could reach the well within a specified time, often five years.
GWUDI
Groundwater under the direct influence of surface water; requires 4-log virus treatment under the Groundwater Rule.
Shock chlorination
Disinfection of a well with a strong chlorine solution, commonly 100 mg/L, held for at least 24 hours.
Tier 1 public notice
Required within 24 hours for acute violations such as E. coli MCL or loss of pressure; must reach all consumers.
Consumer Confidence Report
Annual water quality report delivered to customers by July 1, summarizing source water and detected contaminants.
Monthly operating report
Report of flows, chemical doses, residuals, and compliance data that Michigan systems submit to EGLE.
Stage 2 DBPR
Federal rule limiting TTHM to 80 µg/L and HAA5 to 60 µg/L at each distribution monitoring location.
Groundwater Rule
Federal rule requiring 4-log virus treatment or monitoring for groundwater systems at risk of fecal contamination.
Operator certification
Michigan requires certified treatment and distribution operators for community water supplies, with continuing education units needed for renewal.
Chlorine gas IDLH
Immediately dangerous to life or health concentration is 10 ppm; use supplied-air respiratory protection and evacuate upwind.
Confined space oxygen
Acceptable entry range is 19.5 to 23.5 percent oxygen; entry requires a permit and atmospheric testing.
Trench protective system
Required at five feet depth or deeper; spoil piles kept at least two feet from the edge.
Boil water advisory
Issued when pressure falls below 20 psi or contamination is suspected; Tier 1 notice within 24 hours.
Lockout tagout
Isolate and lock energy sources, then verify zero energy before servicing pumps, motors, or electrical equipment.