MN Boiler Operator flashcards
MN Boiler Operator · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- ASME Section I
- Code covering power boilers over 15 psi steam, including design, materials, fabrication, and required fittings such as safety valves and gauge glasses.
- MAWP
- Maximum allowable working pressure stamped on the boiler nameplate; safety valve settings and operating limits must not exceed this value.
- Water column height rule
- Lowest visible water level in the gauge glass must be at least 2 inches above the highest fire line or heating surface, confirmed by try cocks.
- Hydrostatic test pressure
- For new construction, test at 1.5 times MAWP; for existing boilers under repair, ASME permits testing at the stamped MAWP with jurisdiction approval.
- Pre-start purge
- Before any ignition attempt, run forced and induced draft fans to move at least four air changes through the furnace and gas passages.
- Light-off sequence
- Purge, prove igniter flame, open fuel valve, prove main flame within trial-for-ignition time; failure closes fuel and locks out the burner.
- Cold boiler warm-up
- Raise pressure over 1 to 4 hours, keep drum metal temperature rise near 100 °F per hour, and keep superheater drains open until steam flows.
- Bottom blowdown rule
- Blow down at low to moderate firing with the boiler under load, one valve at a time, short duration; never blow down during low water.
- Stoichiometric methane
- CH4 + 2O2 yields CO2 + 2H2O; theoretical air is about 10 cubic feet per cubic foot of natural gas.
- Excess air targets
- Typically 15 to 25 percent for natural gas and 20 to 30 percent for fuel oil; tune to the lowest excess air with no CO rise or smoke.
- Stack loss rule
- Each 40 °F rise in flue gas temperature above boiler water or steam temperature costs roughly 1 percent boiler efficiency.
- Furnace draft
- Normally held slightly negative, about 0.05 to 0.10 inches water column, to keep hot gas in the furnace and prevent leakage.
- Safety valve testing
- Pop the valve at operating pressure; a valve that leaks or fails to reseat must be repaired or replaced by a qualified valve shop.
- Low-water cutoff test
- Lower water level with the burner firing; confirm fuel stops and manual reset prevents restart until water is restored to a safe level.
- Minnesota inspection rule
- Boilers and pressure vessels must be inspected by a state or commissioned inspector at rule-set intervals, and the certificate must be posted.
- Boiler horsepower
- One boiler horsepower equals 33,475 Btu per hour, about 34.5 pounds of steam per hour from and at 212 °F.
- Firetube vs watertube
- Firetube boilers pass hot gas through tubes surrounded by water; watertube boilers pass water through tubes surrounded by hot gas.
- Superheater protection
- Superheater tubes need steam flow for cooling; open drains during warm-up and protect the superheater during light-off and low load.
- Main steam stop valve
- A stop or stop-check valve on the boiler outlet that isolates the boiler from the header and prevents backflow on a multi-boiler plant.
- Paralleling a boiler
- Warm and drain the steam header, match boiler pressure to header pressure, then open the main steam stop slowly to bring the boiler on line.
- Foaming and carryover
- Caused by high dissolved solids, high alkalinity, or oil contamination; blow down, test boiler water, and treat to correct.
- Wet vs dry layup
- Wet layup uses treated water with an oxygen scavenger and nitrogen blanket; dry layup uses desiccant and sealed openings.
- Combustion air-fuel ratio
- Burner linkage positions fuel valve and air damper together; mismatch causes smoke or high CO, corrected with a flue gas analyzer.
- Burner turndown
- Ratio of maximum to minimum stable firing rate; a 10:1 turndown allows low fire operation without cycling the burner on and off.
- Flame safeguard lockout
- On flame failure the programmer closes the fuel valve and locks out; a manual reset and full purge are required before the next light-off.
- Safety valve discharge piping
- Must be piped to a safe discharge point with no valve or restriction between the boiler and the valve; piping must be independently supported.
- Flame scanner sighting
- Adjust sighting so the scanner sees only its own flame, not the igniter, refractory glow, or the opposite burner's flame.
- Minnesota operator licensing
- License is by class and boiler horsepower; a licensed operator must be on duty or available as required by the boiler size and type.
- Economizer protection
- Economizer must have water flow before firing and a bypass for startup to prevent steaming; keep feedwater above the acid dew point.
- Pressure gauge siphon
- A siphon coil protects the pressure gauge from steam temperature; the gauge connects to the highest part of the steam space.
- Low water emergency
- If water disappears from the gauge glass, secure the burner immediately and do not add water until the boiler has cooled.
- Boiler room ventilation
- Combustion air and ventilation openings must be kept clear; blocked openings cause incomplete combustion and unsafe conditions.