MN Elevator Mechanic study materials
MN Elevator Mechanic study resources

MN Elevator Mechanic cheat sheet

MN Elevator Mechanic · Keep the key ideas within reach.

Quick reference

Codes and Standards (ASME A17.1/A17.1s, A17.2, A17.3, A17.4, A17.5, A17.6, A18.1)

  • ASME A17.1/CSA B44 is the new-installation safety code; A17.1s is its supplement of addenda and is adopted as part of the code edition it supplements.

  • A17.2 covers inspection and testing of existing elevators and escalators; A17.3 covers existing elevator and escalator upgrades; A17.4 covers emergency evacuation of passengers from stalled cars.

  • A17.5 governs elevator and escalator electrical equipment; A17.6 governs suspension means (wire rope, coated steel belt, and similar) and their terminations and inspection criteria.

  • A18.1 covers platform lifts and stairway chairlifts; it is a separate standard from A17.1 and applies to accessibility lifts not within A17.1 scope.

  • A17.1 Rule 2.26 requires a Type A (car) and Type B (hoistway) safety test: safety applies at 125% of rated load at rated speed for the governor-tripped safety.

  • Governor tripping speed for a car safety is set between 115% and 140% of rated speed for speeds up to 600 ft/min; higher speeds use a lower upper limit per the code table.

  • A17.1 requires a machine-room (or control-space) access door to be self-closing and self-locking, openable from the inside without a key, and at least 29.5 in by 6 ft 8 in clear.

  • Pit access: a pit ladder is required where pit depth exceeds 3 ft, and the ladder must be accessible from the lowest landing door sill or a pit access door.

Quick reference

Electric Elevator Equipment and Components

  • Geared traction machines use a worm gear to transmit power and provide holding; gearless machines couple the sheave directly to the motor and are used for higher speeds.

  • A traction elevator relies on friction between hoist ropes and the drive sheave; the counterweight is typically sized to balance car weight plus about 40-50% of rated load.

  • The car safety is set by a governor; a rope-grip governor grips the governor rope to pull the safety, while a car-mounted overspeed device may trip mechanically.

  • A roller-type safety grips the guide rails progressively; a wedge-type safety is instant in action and is used at lower speeds.

  • Rope data: 1/2 in diameter 6x19 or 8x19 traction rope is common; ropes must be replaced when broken wires, wear, or corrosion exceed A17.6/A17.1 criteria.

  • A brake on a traction machine must be capable of holding 125% of rated load; it is spring-applied and electrically released (fail-safe).

  • The counterweight must have a guard or be enclosed where it can be struck, and counterweight safeties are required on some installations per A17.1.

  • Door operators: a car door must have a door-closed switch and a door-zone/leveling switch; the door operator must close against a force limit to protect passengers.

Quick reference

Hydraulic Elevator Equipment and Components

  • Hydraulic elevators use a power unit (pump, motor, valve) to pressurize oil that pushes a plunger in a cylinder; movement is by fluid displacement, not traction.

  • In-ground (holeless) cylinders are buried in the ground; holeless/jack configurations use above-ground cylinders and are common where drilling is restricted.

  • The lowering valve controls descent by metering oil back to the tank; a ruptured-valve or pipe-break valve limits downward speed if the line breaks.

  • A hydraulic elevator requires a pressure-relief valve set to open at no more than 125% of the design pressure, protecting the system from overpressure.

  • The oil tank must have a vent, and the tank oil level must be maintained; low oil can cause the pump to cavitate and the car to settle.

  • Hydraulic elevators are limited in travel and speed; typical maximum travel is about 60 ft with speeds up to about 200 ft/min for conventional systems.

  • The cylinder must have a means to detect and stop the car if the oil level in the tank drops, and the system must be protected against overtravel.

  • Hydraulic elevators require a check valve to hold the car and a separate lowering valve; the valve must be accessible for maintenance.

Quick reference

Electrical Systems, Wiring, and Control Circuits

  • Elevator power supply must be a dedicated circuit; the main line disconnect must be lockable and located where it is accessible to maintenance personnel.

  • The main line disconnect must be capable of being locked in the open position, and a means must be provided to identify the disconnect and its circuit.

  • Control circuits commonly operate at 120 V AC or 24 V DC; the code requires the control circuit to be protected against overcurrent.

  • The machine room must have lighting of at least 10 ft-candles at the floor, and a grounded receptacle must be provided in the machine room and pit.

  • Grounding: the elevator equipment must be bonded to the building grounding electrode system; the equipment grounding conductor must be sized per the NEC.

  • A phase-reversal or phase-failure relay protects the motor from incorrect phase sequence or loss of a phase on three-phase power.

  • The car must have a light and a two-way communication means (phone or intercom) that works without the building power, typically battery-backed.

  • A ground-fault circuit interrupter is required for pit receptacles and other wet-location receptacles per the NEC and A17.1.

Quick reference

Maintenance, Inspection, and Testing

  • A17.2 requires periodic inspection and testing; the interval is set by the authority having jurisdiction, and Minnesota requires annual inspections for elevators.

  • The Category 1 test is the routine annual test; Category 5 is the full-load safety test performed every 5 years.

  • The no-load safety test verifies governor trip and safety set; the full-load test verifies the safety holds 125% of rated load.

  • The oil level, rope condition, brake wear, door operation, and safety devices should be checked on each maintenance visit.

  • A maintenance record must be kept and made available to the inspector; records document tests, repairs, and code compliance.

  • The pit should be checked for water, debris, and proper lighting; the pit ladder and stop switch must be functional.

  • Escalator maintenance includes step/skirt clearance, handrail speed, comb plate condition, and brake test; the brake must stop a loaded escalator within the code distance.

  • The governor should be tested for tripping speed and the safety for setting; the test tag or record must be updated after each test.

Quick reference

Safety Procedures and Worksite Practices

  • Lockout/tagout: the main disconnect must be locked open and tagged before working on or near electrical components; verify zero energy before touching conductors.

  • Before entering the pit or car top, place the car on inspection operation and verify the stop switch works; never rely on the door interlock alone.

  • Car-top work requires a top-of-car inspection station with a stop switch, and the car top must have a guardrail where required by A17.1.

  • Fall protection: use a body harness and lanyard when working on the car top or near an open hoistway, and never stand on the car crosshead.

  • Barricade the hoistway opening and post warning signs when a landing door is open or removed; never leave an open hoistway unattended.

  • Use proper lifting technique and equipment for heavy components; never stand under a suspended load or under the car.

  • Emergency evacuation must follow A17.4 procedures; only trained personnel should move passengers from a stalled car.

  • Personal protective equipment: hard hat, safety glasses, gloves, and safety shoes are required on the job site; hearing protection is required near loud machinery.

Quick reference

Minnesota Elevator Statutes and Rules

  • Minnesota elevator regulation is administered by the Minnesota Department of Labor and Industry (DLI); the Elevator Safety Code is in Minnesota Rules Chapter 1307.

  • Minnesota adopts ASME A17.1 and related A17 standards by reference in its rules, with amendments published in the state rule chapter.

  • Elevator mechanics in Minnesota must be licensed; the license is issued by DLI and requires passing an examination and meeting experience requirements.

  • A permit is required before installing or altering an elevator; the installation must be inspected by a DLI inspector or approved inspector before use.

  • Minnesota requires periodic inspections, and the owner must maintain a current certificate of inspection posted in the elevator or machine room.

  • The mechanic license must be renewed; continuing education and code-update training may be required for renewal.

  • Report accidents and serious injuries to DLI; the department may investigate and require corrective action.

  • Work on elevators must be performed by licensed personnel or under the direct supervision of a licensed mechanic, per state law.

Quick reference

Escalators, Moving Walks, and Accessibility Lifts

  • Escalator code requirements are in ASME A17.1; escalators must have a brake that stops a loaded step band within the code stopping distance.

  • The comb plate, step/skirt clearance, and handrail speed are key inspection points; handrail speed should match step speed within tolerance.

  • Escalators require a stop switch at the top and bottom landings, and the emergency stop button must be clearly marked.

  • Moving walks are covered by A17.1; the pallet/skirt clearance and handrail/balustrade requirements are similar to escalators.

  • A18.1 platform lifts and stairway chairlifts require a clear landing, a continuous run, and a means to prevent operation outside the intended path.

  • Accessibility lifts must have a means for the user to call for help and must meet the A18.1 requirements for capacity, speed, and guarding.

  • Escalator steps must be checked for missing or broken treads and the step chain for wear; the skirt guard must be intact.

  • A18.1 requires the lift to be inspected and tested; the inspection interval is set by the AHJ and must be documented.