MN Elevator Mechanic study materials
MN Elevator Mechanic study resources

MN Elevator Mechanic flashcards

MN Elevator Mechanic · Build recall with a focused review session.

32 cards. Read the term and the definition here. The deck at the top of this page is optional.

A17.1 scope
ASME A17.1/CSA B44 is the safety code for new elevators, escalators, dumbwaiters, moving walks, and related equipment. It covers design, construction, installation, operation, and maintenance requirements.
A17.2 purpose
ASME A17.2 provides inspection and testing procedures for existing elevators and escalators. It tells inspectors what to check and how to perform periodic tests.
A17.4 evacuation
ASME A17.4 covers emergency evacuation of passengers from stalled elevators. It describes safe procedures for trained personnel to remove passengers without injury.
A17.6 suspension means
ASME A17.6 sets requirements for suspension means such as wire rope and coated steel belts. It covers design, inspection, and replacement criteria for elevator suspension.
A18.1 platform lifts
ASME A18.1 covers platform lifts and stairway chairlifts used for accessibility. It is separate from A17.1 and addresses capacity, guarding, and operation.
Governor trip speed
The car safety governor must trip at a speed between 115% and 140% of rated speed for elevators up to 600 ft/min. Higher speeds use a lower upper limit per the code table.
Traction machine principle
A traction elevator relies on friction between hoist ropes and the drive sheave. A counterweight balances the car and about 40-50% of rated load.
Gearless machine
A gearless traction machine couples the drive sheave directly to the motor shaft. It is used for higher speeds and eliminates worm-gear losses.
Car safety types
A wedge-type safety is instant in action and used at lower speeds. A roller-type safety grips progressively and is used at higher speeds.
Machine brake requirement
The traction machine brake must hold 125% of rated load. It is spring-applied and electrically released so it sets automatically on power loss.
Counterweight function
The counterweight balances the car weight plus about 40-50% of rated load. It reduces motor effort and improves traction between rope and sheave.
Hydraulic power unit
A hydraulic elevator power unit consists of a pump, motor, valve, and oil tank. The pump pressurizes oil to push the plunger and raise the car.
Relief valve setting
The hydraulic pressure-relief valve must open at no more than 125% of design pressure. It protects the cylinder, piping, and fittings from overpressure.
Ruptured valve function
A ruptured-valve or pipe-break valve limits downward speed if the hydraulic line breaks. It protects against uncontrolled descent of the car.
Hydraulic travel limits
Conventional hydraulic elevators are limited to about 60 ft of travel and speeds up to about 200 ft/min. In-ground cylinders and oil volume constrain height.
Main line disconnect
The elevator main line disconnect must be lockable in the open position and accessible to maintenance personnel. It must be identified and dedicated to the elevator.
Phase reversal relay
A phase-reversal or phase-failure relay protects a three-phase motor from incorrect phase sequence or loss of a phase. It prevents motor damage.
Machine room lighting
The machine room must have lighting of at least 10 ft-candles at the floor. A grounded receptacle must also be provided in the machine room and pit.
Two-way communication
The car must have a two-way communication means, such as a phone or intercom, that works without building power. It is typically battery-backed.
Category 1 test
The Category 1 test is the routine periodic test performed during inspection. It checks safety devices and operation without the full-load safety test.
Category 5 test
The Category 5 test is the full-load safety test performed every five years. It verifies the safety can stop and hold 125% of rated load.
Maintenance records
Maintenance records must document tests, repairs, and code compliance. They must be available to the inspector and kept current.
Lockout/tagout
Lockout/tagout requires the main disconnect to be locked open and tagged before electrical work. Verify zero energy before touching conductors.
Car-top inspection station
The car top must have an inspection station with a stop switch and operating controls. A guardrail is required where the code specifies.
Hoistway barricade
An open or removed landing door must be barricaded and marked with warning signs. An open hoistway must never be left unattended.
Minnesota DLI authority
The Minnesota Department of Labor and Industry administers elevator regulation. The Elevator Safety Code is in Minnesota Rules Chapter 1307.
Minnesota mechanic license
Minnesota requires elevator mechanics to be licensed by DLI. Licensing requires passing an examination and meeting experience requirements.
Minnesota permit requirement
A permit is required before installing or altering an elevator in Minnesota. The installation must be inspected before it is placed in service.
Escalator brake test
An escalator brake must stop a loaded step band within the code stopping distance. The brake is tested during periodic inspection.
Escalator comb plate
The comb plate and step/skirt clearance are key escalator inspection points. Missing or broken treads and worn step chains must be corrected.
Moving walk requirements
Moving walks are covered by ASME A17.1. Pallet/skirt clearance and handrail/balustrade requirements are similar to escalator requirements.
A18.1 lift inspection
A18.1 platform lifts and stairway chairlifts must be inspected and tested. The inspection interval is set by the authority having jurisdiction.