MS HVAC study materials
MS HVAC study resources

MS HVAC study plan

MS HVAC · Give each week a clear focus.

8 weeks · About 6 hours per week

Week 1

HVACR Core Knowledge and Skills

  • Define and correctly apply the core thermodynamics terms used across the exam: sensible heat, latent heat, superheat, subcooling, enthalpy, and saturation.

  • Convert between Fahrenheit, Celsius, PSIG, PSIA, and absolute temperature without a reference sheet, showing unit labels at each step.

  • Interpret a standard pressure-enthalpy diagram well enough to locate the four basic cycle points for a simple vapor-compression system.

  • Explain the function of each major HVACR system component (compressor, condenser, metering device, evaporator) in plain language.

Your checkpoint

A one-page handwritten conversion and formula sheet (temperature, pressure, superheat/subcooling, airflow equations) solved cold with no notes, scored at 90% or better on a 20-item self-quiz.

Week 2

Refrigeration Systems and Components

  • Trace refrigerant flow through a vapor-compression circuit and state the phase and pressure at each of the four points.

  • Calculate superheat and subcooling from gauge and line temperatures for both a fixed-orifice and a TXV system.

  • Identify the symptoms of common faults (undercharge, overcharge, restricted filter-drier, non-condensables) on the pressure-enthalpy diagram.

  • Describe safe refrigerant handling, recovery, and evacuation practices to the level of EPA Section 608 concepts.

Your checkpoint

A completed fault-diagnosis chart listing at least six refrigerant-side faults with the expected suction pressure, head pressure, superheat, and subcooling signature for each.

Week 3

Refrigeration Systems and Components & HVACR Core Knowledge and Skills

  • Compare compressor types (reciprocating, scroll, screw, rotary) by application, capacity range, and common failure modes.

  • Explain how each metering device type (capillary tube, fixed orifice, TXV, EEV) responds to changing load and ambient conditions.

  • Size and select evaporator/condenser coils using approach temperature and airflow assumptions, and justify the selection.

  • Diagnose a system that is running but not cooling using a structured sequence: airflow, charge, then refrigerant-side restriction.

Your checkpoint

A written case diagnosis of two instructor-style scenarios (one low-superheat, one high-superheat) with the recommended corrective action and the reasoning behind each step.

Week 4

Electrical Systems and Controls

  • Read a ladder diagram and a wiring schematic and trace a call for cooling from thermostat through contactor to compressor.

  • Apply Ohm's law and the power equation to compute current, voltage drop, and resistance in a control and load circuit.

  • Test capacitors, contactors, relays, and thermistors with a multimeter and state the pass/fail criteria for each.

  • Explain the role of safeties (high/low pressure switches, overloads, freeze stats) and how each interrupts the circuit.

Your checkpoint

A redrawn ladder diagram of a basic residential cooling circuit with every component labeled and a measured-versus-expected value table for a live or simulated test.

Week 5

Electrical Systems and Controls & Heating Systems and System Performance

  • Differentiate line-voltage from low-voltage control wiring and identify code-relevant installation requirements for each.

  • Describe how a heat pump defrost control, reversing valve, and auxiliary heat staging interact during a heating call.

  • Calculate electric-resistance heat capacity in kW and BTUH and verify it against nameplate data.

  • Diagnose a no-heat call on a heat pump by isolating the thermostat, control board, and outdoor unit in sequence.

Your checkpoint

A troubleshooting flowchart for a heat pump no-heat complaint with at least eight decision points and the expected reading at each test location.

Week 6

Air Distribution, Ductwork, and Indoor Air Quality

  • Apply the sensible heat equation to compute required airflow from load, temperature rise, and CFM relationships.

  • Measure external static pressure and use a fan performance table to determine delivered CFM.

  • Size and lay out a simple trunk-and-branch duct system, accounting for friction loss and equivalent length of fittings.

  • Identify the causes and corrections for common duct defects: leakage, undersized returns, excessive flex sag, and poor transitions.

Your checkpoint

A duct layout sketch for a single-zone system with a static pressure budget and a calculated CFM at each branch, checked against a fan curve.

Week 7

Air Distribution, Ductwork, and Indoor Air Quality & Heating Systems and System Performance

  • Explain the three pillars of indoor air quality (source control, ventilation, filtration) and how each is applied in a residential retrofit.

  • Interpret MERV ratings and select filtration appropriate to a given equipment static pressure limit.

  • Compute combustion air requirements and identify venting and draft problems on a natural-gas furnace.

  • Measure temperature rise across a furnace and compare it to the nameplate range to judge airflow and combustion adequacy.

Your checkpoint

A combustion-analysis and airflow verification report for one furnace scenario, including temperature rise, expected versus measured, and a written recommendation.

Week 8

HVACR Core Knowledge and Skills & Refrigeration Systems and Components & Electrical Systems and Controls & Air Distribution, Ductwork, and Indoor Air Quality & Heating Systems and System Performance

  • Integrate all five domains by diagnosing two full-system scenarios that combine refrigerant, electrical, airflow, and heating faults.

  • Complete timed practice sets under exam conditions to build pacing and reduce careless errors.

  • Review every missed item from weeks 1 through 7 and restate the underlying principle in your own words.

  • Confirm readiness by scoring consistently above the target threshold on mixed-domain practice.

Your checkpoint

Two full-length timed practice exams completed with a written error log; every missed question corrected with the governing principle and the reference source.

Milestones

Week 2: Score 80% or better on a 25-item mixed quiz covering domains 1 and 2, and correctly compute superheat and subcooling for four sample systems without notes.

Week 4: Trace a cooling call through a ladder diagram end-to-end in under five minutes and correctly identify the fault in three of four injected electrical scenarios.

Week 6: Compute required CFM from a given load and temperature difference and match it to within 10% of the value derived from a fan performance table.

Week 8: Achieve the target passing score on two consecutive timed full-length practice exams, with no domain scoring below 70%.