MT Water/Wastewater Operator key terms
MT Water/Wastewater Operator · Get comfortable with the vocabulary.
- Coagulation
- Related: Flocculation, Turbidity
The rapid mixing of a chemical such as alum or ferric chloride into raw water to neutralize particle charges so that tiny suspended solids begin to clump together. It is the first step of conventional clarification.
- Flocculation
- Related: Coagulation, Sedimentation Basin
Gentle, slow stirring after coagulation that encourages small destabilized particles to collide and grow into larger, settleable masses called floc. Mixing energy is kept low so the floc is not sheared apart before settling.
- Turbidity
- Related: Coagulation, Filter Backwash
A measure of how cloudy water is because suspended particles scatter light. It is reported in nephelometric turbidity units (NTU) and serves as both a treatment performance indicator and a regulatory limit for filtered water.
- Sedimentation Basin
- Related: Flocculation, Sludge
A quiet tank where floc and other solids settle to the bottom as sludge before water flows on to filters. Detention time and flow distribution are managed so particles have time to reach the floor.
- Filter Backwash
- Related: Turbidity, Head Loss
Reversing flow upward through a filter bed to dislodge trapped particles and flush them to waste. Backwash is triggered by head loss, turbidity breakthrough, or a set run time, and the filter is then returned to service.
- Head Loss
- Related: Filter Backwash, Pressure Gauge
The drop in pressure or water level as water moves through a filter bed or pipe. Rising head loss across a filter signals clogging and is one of the triggers for backwashing.
- Disinfection Byproducts
- Related: CT Value, Total Organic Carbon
Compounds such as trihalomethanes and haloacetic acids that form when disinfectants like chlorine react with naturally occurring organic matter in water. Utilities control them by removing precursors and managing disinfectant doses.
- CT Value
- Related: Disinfection Byproducts, Clearwell
The product of disinfectant residual concentration (C) and contact time (T) used to demonstrate that a required level of pathogen inactivation has been achieved. CT requirements vary by disinfectant, target organism, and water temperature.
- Clearwell
- Related: CT Value, Finished Water
A storage tank or basin that holds finished water long enough to provide the contact time needed for disinfection and to buffer supply against demand variations. It is usually the last treatment step before high-service pumps.
- Total Organic Carbon
- Related: Disinfection Byproducts, Coagulation
A measurement of the carbon content of organic compounds in water. High levels can feed biological growth in the distribution system and react with disinfectants to form byproducts, so utilities often target removal during treatment.
- Finished Water
- Related: Clearwell, Distribution System
Water that has completed all treatment processes and meets quality standards for entry into the distribution system. Its quality is monitored at the plant and at points throughout the system.
- Distribution System
- Related: Finished Water, Booster Chlorination
The network of pipes, pumps, valves, tanks, and meters that delivers finished water from the treatment plant to customers. Operators must maintain adequate pressure, disinfectant residual, and water quality throughout it.
- Booster Chlorination
- Related: Distribution System, Disinfectant Residual
Adding a small dose of disinfectant at points within the distribution system to maintain a residual that protects against contamination and biological growth far from the treatment plant.
- Disinfectant Residual
- Related: Booster Chlorination, Cross-Connection
The concentration of disinfectant remaining in water as it travels through the distribution system. A detectable residual is required in most systems and is checked at sample sites to confirm protection against microbial contamination.
- Cross-Connection
- Related: Backflow Prevention, Disinfectant Residual
Any actual or potential link between a potable water supply and a source of contamination, such as a hose submerged in a chemical tank. Backflow prevention devices and air gaps are used to eliminate the hazard.
- Backflow Prevention
- Related: Cross-Connection, Pressure Gauge
Devices or physical arrangements, such as air gaps, reduced-pressure-zone assemblies, and vacuum breakers, that stop contaminated water from flowing backward into the drinking water supply when pressure conditions reverse.
- Pressure Gauge
- Related: Head Loss, Surge
An instrument that displays the pressure of water in a pipe, pump discharge, or filter. Operators use gauge readings to confirm adequate system pressure, detect head loss, and identify pump or valve problems.
- Surge
- Related: Pressure Gauge, Distribution System
A sudden pressure wave in a pipeline caused by rapidly stopping or starting flow, such as a fast valve closure or pump trip. Surges can damage pipes and appurtenances and are managed with slow valve operation and surge controls.
- Water Main Flushing
- Related: Distribution System, Disinfectant Residual
Deliberately running water at high velocity through mains to scour out sediment, stale water, and biofilm. Flushing is often scheduled after repairs or in low-flow areas and may be combined with disinfection.
- Influent
- Related: Effluent, Biochemical Oxygen Demand
Wastewater or water flowing into a treatment unit or plant. Its flow rate and characteristics are measured to set process controls and to calculate loading and removal efficiency.
- Effluent
- Related: Influent, National Pollutant Discharge Elimination System
Treated water leaving a treatment process or plant and discharged to a receiving water or reuse system. Effluent quality is monitored against permit limits before release.
- Biochemical Oxygen Demand
- Related: Influent, Activated Sludge
The amount of dissolved oxygen consumed by microorganisms while breaking down organic matter in a water sample over a set period, usually five days. It is a common measure of organic strength in wastewater and treatment performance.
- Activated Sludge
- Related: Return Activated Sludge, Biochemical Oxygen Demand
A secondary treatment process in which a mixed population of microorganisms consumes organic matter in an aerated tank, after which the biomass is settled and partly returned to the aeration basin to maintain the population.
- Return Activated Sludge
- Related: Activated Sludge, Waste Activated Sludge
Settled biomass collected in the secondary clarifier and pumped back to the aeration tank to keep the microbial population high enough to treat incoming organic load. The amount returned is a key process control adjustment.
- Waste Activated Sludge
- Related: Return Activated Sludge, Sludge
Excess biomass that is deliberately removed from the activated sludge system to control the solids inventory and maintain the desired sludge age. It is typically thickened and dewatered before disposal.
- Sludge
- Related: Waste Activated Sludge, Sedimentation Basin
The solids-rich material separated from water or wastewater during settling, thickening, or dewatering. Sludge is stabilized and disposed of or beneficially reused, and its handling is a major operating cost.
- Sludge Age
- Related: Waste Activated Sludge, Mixed Liquor Suspended Solids
The average length of time solids remain in an activated sludge system, calculated as the mass of solids in the aeration tank divided by the mass leaving daily. It influences treatment stability and settling behavior.
- Mixed Liquor Suspended Solids
- Related: Activated Sludge, Sludge Age
The concentration of solids, mostly microorganisms, in the aeration tank of an activated sludge system. It is measured regularly and used with sludge age to control how much biomass is kept in the process.
- Infiltration and Inflow
- Related: Sanitary Sewer Overflow, Sewer Smoke Testing
Two sources of unwanted clear water entering a sewer: infiltration seeps in through defective pipes and joints, while inflow enters directly through connections like roof drains and manhole covers during storms.
- Sanitary Sewer Overflow
- Related: Infiltration and Inflow, Sewer Smoke Testing
An unauthorized release of untreated sewage from a collection system before it reaches the treatment plant, often caused by blockages, root intrusion, or storm-driven flows. Overflows must be reported and corrected promptly.
- Sewer Smoke Testing
- Related: Infiltration and Inflow, Sanitary Sewer Overflow
Blowing non-toxic smoke into a sewer line to reveal defects such as broken pipes, illegal connections, and cross-connections with storm drains. Smoke escaping at ground level or inside buildings indicates a problem to repair.
- Lift Station
- Related: Sanitary Sewer Overflow, Confined Space Entry
A facility with pumps that raise wastewater so it can continue flowing by gravity to a treatment plant. Operators monitor wet-well levels, pumps, and alarms to prevent overflows and equipment damage.
- National Pollutant Discharge Elimination System
- Related: Effluent, Sanitary Sewer Overflow
The federal permitting program that sets limits on pollutants in wastewater and stormwater discharged to surface waters. Permits define monitoring requirements, reporting, and effluent limits that facilities must meet.
- Maximum Contaminant Level
- Related: Consumer Confidence Report, Turbidity
The highest concentration of a contaminant allowed in drinking water delivered to consumers under federal and state rules. Some contaminants instead have a treatment technique requirement when a numeric level is not practical.
- Consumer Confidence Report
- Related: Maximum Contaminant Level, Finished Water
An annual report that community water systems must provide to customers summarizing water quality results, detected contaminants, and other required information. It must be delivered by a set deadline each year.
- Confined Space Entry
- Related: Lift Station, Hydrogen Sulfide
The controlled procedure for entering spaces such as manholes, wet wells, and vaults that have limited entry and exit and are not designed for continuous occupancy. Entry requires atmospheric testing, ventilation, a permit, and an attendant.
- Hydrogen Sulfide
- Related: Confined Space Entry, Sludge
A toxic, flammable gas with a rotten-egg odor that forms in sewers and digesters as organic matter decays without oxygen. It is deadly in confined spaces and can also corrode concrete.
- Lockout Tagout
- Related: Lift Station, Confined Space Entry
The safety practice of isolating energy sources, such as electrical disconnects or valves, and attaching a personal lock and tag before servicing equipment. It prevents unexpected startup or release of stored energy that could injure workers.
- Chain of Custody
- Related: Effluent, Consumer Confidence Report
The documented record of who collected, handled, and transported a water or wastewater sample from collection through analysis. It preserves sample integrity and supports enforcement or compliance decisions.