NABCEP PV key terms
NABCEP PV · Get comfortable with the vocabulary.
- Azimuth
- Related: Tilt Angle, Shading Analysis
The compass direction a PV array or roof plane faces, expressed in degrees clockwise from true north; 180 degrees means due south. It strongly affects annual energy production.
- Tilt Angle
- Related: Azimuth, Shading Analysis
The angle between a PV array's surface and horizontal ground, usually chosen to balance summer and winter production and to help rain or snow shed.
- Shading Analysis
- Related: Tilt Angle, Bypass Diode
A site evaluation that identifies objects blocking sunlight and estimates when and how much they shade the array, often using a solar pathfinder or modeling software.
- Irradiance
- Related: Peak Sun Hours, Performance Ratio
The instantaneous power of sunlight striking a surface per unit area, measured in watts per square meter. It changes with time of day, season, clouds, and orientation.
- Peak Sun Hours
- Related: Irradiance, Nameplate Rating
The equivalent number of hours per day when sunlight averages 1,000 watts per square meter. It converts daily solar energy into a convenient number for sizing calculations.
- Standard Test Conditions (STC)
- Related: Nameplate Rating, Temperature Coefficient of Pmax
Laboratory conditions of 1,000 watts per square meter irradiance, 25 degrees Celsius cell temperature, and a specified air mass, used to rate PV modules.
- Nameplate Rating
- Related: Standard Test Conditions (STC), Temperature Coefficient of Pmax
The DC power a PV module is rated to produce under Standard Test Conditions, printed on its label. Real-world output usually differs because operating conditions vary.
- Temperature Coefficient of Pmax
- Related: Nameplate Rating, Irradiance
The percentage change in a module's maximum power for each degree Celsius its cell temperature differs from 25 degrees. It is usually a negative value.
- Open-Circuit Voltage (Voc)
- Related: String Sizing, Short-Circuit Current (Isc)
The maximum voltage a PV module or string produces when no current flows. It rises in cold weather, so it sets the highest voltage the system must withstand.
- Short-Circuit Current (Isc)
- Related: Open-Circuit Voltage (Voc), IV Curve
The current that flows when a module's output terminals are directly connected together. It is used for conductor and overcurrent device sizing.
- IV Curve
- Related: Maximum Power Point Tracking (MPPT), Short-Circuit Current (Isc)
A graph of current versus voltage for a PV device, showing how output changes across its operating range. Maximum power occurs at the knee of the curve.
- Maximum Power Point Tracking (MPPT)
- Related: IV Curve, Inverter
An inverter or charge controller function that continuously adjusts operating voltage to draw the most power available from a PV array as conditions change.
- String
- Related: String Sizing, Open-Circuit Voltage (Voc)
A group of PV modules connected in series so their voltages add and the same current flows through each module. String length must match inverter voltage limits.
- String Sizing
- Related: String, Open-Circuit Voltage (Voc)
Choosing how many modules to connect in series so string voltage stays within the inverter's allowed window at record cold and hot cell temperatures.
- DC-to-AC Ratio
- Related: Inverter, Nameplate Rating
The ratio of a PV array's DC nameplate power to the inverter's AC output rating. A higher ratio can increase energy harvest but causes more clipping.
- Inverter
- Related: Maximum Power Point Tracking (MPPT), DC-to-AC Ratio
A device that converts direct current from PV modules into alternating current suitable for loads or the utility grid, and typically controls array operation.
- Bypass Diode
- Related: Shading Analysis, Hot Spot
A diode inside a PV module that provides an alternate path for current when cells are shaded or damaged, limiting hot spots and power loss.
- Racking
- Related: Flashing, Tilt Angle
The structural mounting system that supports PV modules and transfers wind, snow, and seismic loads to the roof or ground while setting tilt and orientation.
- Flashing
- Related: Racking
A weatherproofing detail installed around roof penetrations and mounting hardware to direct water away and prevent leaks into the building.
- Conduit Fill
- Related: Disconnect
The percentage of a conduit's cross-sectional area occupied by conductors. Limits prevent overheating and make wire pulling practical.
- Commissioning
- Related: Insulation Resistance Test, IV Curve Tracing
The systematic verification after installation that a PV system is safe, complete, and operating as designed, including inspections, tests, and documentation before handover.
- Insulation Resistance Test
- Related: Commissioning, Ground-Fault Protection Device (GFPD)
A test that applies high DC voltage between conductors and ground to check for damaged insulation, moisture, or leakage paths before energizing a system.
- IV Curve Tracing
- Related: IV Curve, Hot Spot
A field test that sweeps a string's current and voltage to produce a curve, allowing comparison with expected performance and identification of faults.
- Performance Ratio
- Related: Soiling, Irradiance
The ratio of a PV system's actual energy output to its theoretical output based on measured irradiance, expressing losses from temperature, soiling, wiring, and availability.
- Soiling
- Related: Performance Ratio, Irradiance
Accumulation of dust, pollen, bird droppings, or snow on PV modules that reduces the sunlight reaching cells and lowers energy production until cleaned.
- Hot Spot
- Related: Bypass Diode, IV Curve Tracing
A localized overheated area on a PV module caused by a shaded, cracked, or failing cell, which can damage the module and sometimes pose a fire risk.
- Lockout/Tagout
- Related: Disconnect, Arc Flash
A safety procedure that isolates energy sources, applies locks and tags, and verifies zero energy before work begins, preventing accidental energization or release of stored energy.
- Arc Flash
- Related: Personal Protective Equipment (PPE), Lockout/Tagout
A dangerous release of energy caused by an electrical arc between conductors, producing intense heat, light, and pressure that can injure workers and damage equipment.
- Personal Protective Equipment (PPE)
- Related: Arc Flash, Fall Protection
Clothing and equipment such as gloves, arc-rated clothing, eye protection, and fall protection worn to reduce injury from electrical, thermal, and physical hazards.
- Fall Protection
- Related: Personal Protective Equipment (PPE), Site Hazard Assessment
Systems and practices such as harnesses, anchor points, and guardrails that prevent or arrest falls when working on roofs or elevated structures.
- Site Hazard Assessment
- Related: Fall Protection, Lockout/Tagout
A pre-work review of a job site that identifies electrical, fall, weather, traffic, and other hazards and defines controls before installation or service begins.
- Rapid Shutdown
- Related: Disconnect, Arc Flash
A code-required system that reduces voltage at PV modules or conductors near the array to a safe level for firefighters within a specified time after activation.
- Arc-Fault Circuit Interrupter (AFCI)
- Related: Ground-Fault Protection Device (GFPD), Arc Flash
A protective device that detects characteristic electrical signatures of dangerous DC arc faults in PV circuits and interrupts the circuit to reduce fire risk.
- Ground-Fault Protection Device (GFPD)
- Related: Equipment Grounding Conductor (EGC), Bonding
A device that detects current leaking from PV circuits to ground and opens the circuit, protecting people and equipment from fault conditions.
- Equipment Grounding Conductor (EGC)
- Related: Bonding, Ground-Fault Protection Device (GFPD)
A conductor that connects non-current-carrying metal parts of equipment to the grounding system so fault current has a low-impedance path back to the source.
- Bonding
- Related: Equipment Grounding Conductor (EGC), Ground-Fault Protection Device (GFPD)
Electrically connecting metal parts so they remain at the same potential, preventing dangerous voltage differences and providing a path for fault current.
- Disconnect
- Related: Lockout/Tagout, Rapid Shutdown
A switch or device that opens all ungrounded conductors of a circuit so equipment can be safely serviced or isolated from all sources of power.
- Interconnection Agreement
- Related: Net Metering, Scope of Work
A contract between a PV system owner and the utility that defines technical requirements, metering, and operating terms for connecting the system to the grid.
- Net Metering
- Related: Interconnection Agreement
A billing arrangement that credits a customer for excess PV electricity exported to the grid, often at the retail rate, offsetting energy imported at other times.
- Scope of Work
- Related: Interconnection Agreement
A written description of the work a contractor will perform, including equipment, quantities, exclusions, schedule, and responsibilities, used to set customer expectations.