NABCEP SH Associate study materials
NABCEP SH Associate study resources

NABCEP SH Associate flashcards

NABCEP SH Associate · Build recall with a focused review session.

32 cards. Read the term and the definition here. The deck at the top of this page is optional.

Peak sun hours
Daily solar insolation expressed as equivalent hours at 1 kW/m² irradiance; numerically equals kWh/m²/day and is used to size array output.
Load analysis
Summing appliance wattage times daily hours to compute Wh/day demand, then applying system losses to size the array and battery bank.
Solar window
The portion of the day when the array receives unobstructed sunlight, determined by sun-path and obstruction survey.
Usable roof area
The portion of roof free of obstructions and fire-access pathways, used to determine maximum module count and layout.
Depth of discharge
The fraction of battery capacity that is discharged in normal use; usable capacity equals nominal capacity times DoD.
Continuous load factor
NEC requires continuous loads to be multiplied by 1.25 when sizing conductors and overcurrent protection devices.
Rapid shutdown
NEC 690.12 requirement that PV conductors near the array be reduced to 30 V or less within 30 seconds of shutdown.
Maximum system voltage
Module open-circuit voltage multiplied by the cold-temperature correction factor; must not exceed equipment voltage ratings.
OCPD sizing rule
PV overcurrent protection is sized at 1.25 times Isc multiplied by 1.25, then rounded up to the next standard rating.
Arc-flash hazard
Dangerous energy release from electrical faults; requires arc-rated PPE and incident-energy analysis before energized work.
UL 1741
Standard covering inverters and grid-support functions, including anti-islanding and interconnection requirements for grid-tied systems.
Temperature coefficient
The rate at which module power or voltage changes per degree Celsius; typically negative for power, meaning output drops as cells heat.
Cold-temperature Voc
At low ambient temperatures, module open-circuit voltage rises; use the coldest expected temperature for maximum voltage calculations.
Soiling losses
Energy lost when dust, pollen, or debris covers modules; can reach 5–20 % in arid regions and is reduced by cleaning schedules.
Off-grid autonomy
The number of days a battery bank can supply loads without sun; typically 2–5 days depending on criticality and climate.
Hybrid inverter
An inverter that manages PV, battery storage, and grid interaction, enabling backup power to critical-load subpanels.
Corrosion-resistant racking
Anodized aluminum and stainless hardware specified for coastal or marine sites to resist salt-fog degradation and galvanic corrosion.
True south azimuth
In the northern hemisphere, fixed arrays face true south (180°); deviations of 15–20° typically cost only a few percent of yield.
Optimal tilt
Tilt approximately equal to latitude maximizes annual yield; steeper tilt favors winter production and sheds snow.
Row spacing
Inter-row distance set to avoid shading between about 9 a.m. and 3 p.m. on winter solstice, based on tilt and latitude.
Flush-mount racking
Roof-parallel mounting that minimizes wind uplift and visual impact but reduces airflow and can lower cell cooling.
Clamp zones
Manufacturer-specified locations on module frames where mounting clamps may be attached; clamping elsewhere voids warranty.
Equipment grounding
Bonding module frames and racking to a continuous grounding conductor with listed hardware to clear ground faults safely.
String combiner
A box that parallels multiple PV strings with per-string fuses and a DC disconnect before the inverter.
MPPT controller
Maximum power point tracking charge controller that adjusts operating voltage to harvest maximum array power, especially in larger systems.
DC-rated disconnect
A switch rated for direct-current PV circuits, required because DC arcs do not self-extinguish at zero crossing like AC.
DC/AC ratio
The ratio of array DC nameplate to inverter AC rating; typically 1.0–1.3, allowing clipping but improving low-light output.
PV-rated conductor
Sunlight-resistant, wet-rated wire suitable for outdoor PV circuits, often used with UV-rated conduit and proper strain relief.
Soiling inspection
Scheduled visual check for dust, pollen, and bird droppings; cleaning with water and soft brushes restores output without abrasion.
Hot spot detection
Thermal imaging reveals localized overheating from cell defects, bypass-diode failures, or loose terminations not visible to the eye.
Performance ratio
The ratio of actual to theoretical energy yield; tracking it over time reveals degradation and maintenance needs.
Maintenance log
A record of inspection dates, findings, and corrective actions that supports warranty claims and performance trend analysis.