NABCEP SH Associate flashcards
NABCEP SH Associate · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Peak sun hours
- Daily solar insolation expressed as equivalent hours at 1 kW/m² irradiance; numerically equals kWh/m²/day and is used to size array output.
- Load analysis
- Summing appliance wattage times daily hours to compute Wh/day demand, then applying system losses to size the array and battery bank.
- Solar window
- The portion of the day when the array receives unobstructed sunlight, determined by sun-path and obstruction survey.
- Usable roof area
- The portion of roof free of obstructions and fire-access pathways, used to determine maximum module count and layout.
- Depth of discharge
- The fraction of battery capacity that is discharged in normal use; usable capacity equals nominal capacity times DoD.
- Continuous load factor
- NEC requires continuous loads to be multiplied by 1.25 when sizing conductors and overcurrent protection devices.
- Rapid shutdown
- NEC 690.12 requirement that PV conductors near the array be reduced to 30 V or less within 30 seconds of shutdown.
- Maximum system voltage
- Module open-circuit voltage multiplied by the cold-temperature correction factor; must not exceed equipment voltage ratings.
- OCPD sizing rule
- PV overcurrent protection is sized at 1.25 times Isc multiplied by 1.25, then rounded up to the next standard rating.
- Arc-flash hazard
- Dangerous energy release from electrical faults; requires arc-rated PPE and incident-energy analysis before energized work.
- UL 1741
- Standard covering inverters and grid-support functions, including anti-islanding and interconnection requirements for grid-tied systems.
- Temperature coefficient
- The rate at which module power or voltage changes per degree Celsius; typically negative for power, meaning output drops as cells heat.
- Cold-temperature Voc
- At low ambient temperatures, module open-circuit voltage rises; use the coldest expected temperature for maximum voltage calculations.
- Soiling losses
- Energy lost when dust, pollen, or debris covers modules; can reach 5–20 % in arid regions and is reduced by cleaning schedules.
- Off-grid autonomy
- The number of days a battery bank can supply loads without sun; typically 2–5 days depending on criticality and climate.
- Hybrid inverter
- An inverter that manages PV, battery storage, and grid interaction, enabling backup power to critical-load subpanels.
- Corrosion-resistant racking
- Anodized aluminum and stainless hardware specified for coastal or marine sites to resist salt-fog degradation and galvanic corrosion.
- True south azimuth
- In the northern hemisphere, fixed arrays face true south (180°); deviations of 15–20° typically cost only a few percent of yield.
- Optimal tilt
- Tilt approximately equal to latitude maximizes annual yield; steeper tilt favors winter production and sheds snow.
- Row spacing
- Inter-row distance set to avoid shading between about 9 a.m. and 3 p.m. on winter solstice, based on tilt and latitude.
- Flush-mount racking
- Roof-parallel mounting that minimizes wind uplift and visual impact but reduces airflow and can lower cell cooling.
- Clamp zones
- Manufacturer-specified locations on module frames where mounting clamps may be attached; clamping elsewhere voids warranty.
- Equipment grounding
- Bonding module frames and racking to a continuous grounding conductor with listed hardware to clear ground faults safely.
- String combiner
- A box that parallels multiple PV strings with per-string fuses and a DC disconnect before the inverter.
- MPPT controller
- Maximum power point tracking charge controller that adjusts operating voltage to harvest maximum array power, especially in larger systems.
- DC-rated disconnect
- A switch rated for direct-current PV circuits, required because DC arcs do not self-extinguish at zero crossing like AC.
- DC/AC ratio
- The ratio of array DC nameplate to inverter AC rating; typically 1.0–1.3, allowing clipping but improving low-light output.
- PV-rated conductor
- Sunlight-resistant, wet-rated wire suitable for outdoor PV circuits, often used with UV-rated conduit and proper strain relief.
- Soiling inspection
- Scheduled visual check for dust, pollen, and bird droppings; cleaning with water and soft brushes restores output without abrasion.
- Hot spot detection
- Thermal imaging reveals localized overheating from cell defects, bypass-diode failures, or loose terminations not visible to the eye.
- Performance ratio
- The ratio of actual to theoretical energy yield; tracking it over time reveals degradation and maintenance needs.
- Maintenance log
- A record of inspection dates, findings, and corrective actions that supports warranty claims and performance trend analysis.