North Carolina Low Voltage Practice key terms
North Carolina Low Voltage Practice · Get comfortable with the vocabulary.
- Class 2 circuit
- Related: Class 3 circuit, CL3P cable, Power-limited circuit
A circuit supplied by a listed Class 2 power source and limited in voltage and power so it presents a low fire and shock hazard, allowing less restrictive wiring methods.
- Class 3 circuit
- Related: Class 2 circuit, CL3P cable
A circuit supplied by a listed Class 3 power source that is voltage-limited but carries higher current than Class 2, requiring wiring methods closer to those for power circuits.
- Power-limited circuit
- Related: Class 2 circuit, Class 3 circuit, PLTC cable
A circuit whose energy is capped by a listed power source or overcurrent protection in accordance with its article, reducing fire and shock risk and permitting reduced wiring requirements.
- CL3P cable
- Related: CMP cable, Plenum, Class 3 circuit
A plenum-rated Class 3 cable whose jacket and insulation pass the NFPA 262 Steiner tunnel test, permitting installation in ducts and plenums without conduit.
- CMP cable
- Related: CL3P cable, Plenum, Riser-rated cable
Communications plenum cable tested to NFPA 262, used in air-handling spaces; the "P" suffix marks plenum rating for Articles 800 and 820 cables.
- Riser-rated cable
- Related: CMP cable, Riser, Plenum
A cable such as CMR or CL3R tested to UL 1666 for flame propagation in vertical shafts, suitable for risers but not for plenums.
- Plenum
- Related: CMP cable, CL3P cable, Riser
An air-handling space used for supply, return, or exhaust air, such as a dropped ceiling or raised floor, where only plenum-rated wiring and materials are permitted.
- Riser
- Related: Riser-rated cable, Firestop
A vertical shaft or penetration connecting floors of a building through which cables run between levels; cable flame ratings for risers are governed by UL 1666.
- Firestop
- Related: Riser, Plenum, Sleeve
A listed material or assembly installed to seal a penetration through a fire-rated wall, floor, or membrane so the fire rating of the barrier is maintained.
- Sleeve
- Related: Firestop, Conduit fill
A short section of conduit or tubing through a wall or floor that carries cable and protects it from abrasion; a sleeve does not by itself satisfy firestopping requirements.
- Conduit fill
- Related: Sleeve, J-hook support
The percentage of a raceway's internal cross-sectional area occupied by conductors and cables, limited by NEC Chapter 9 tables to allow pulling and heat dissipation.
- J-hook support
- Related: Conduit fill, Cable tray
A hook-shaped hanger used to support bundles of low-voltage cable at intervals specified by the manufacturer and the applicable article, controlling sag and strain.
- Cable tray
- Related: J-hook support, Equipment grounding conductor
A rigid metal or nonmetallic raceway system with open top used to support and route cables; fill, support, and grounding requirements apply under NEC Article 392.
- Abandoned cable
- Related: Plenum, Riser
Installed cable that is not terminated at equipment and not identified for future use, which Articles 725, 760, 770, 800, and 820 require to be removed or tagged.
- Ohm's law
- Related: Voltage drop, Power formula, Series circuit
The relationship stating that voltage equals current multiplied by resistance (E = I × R), used to size conductors and predict voltage drop in low-voltage circuits.
- Power formula
- Related: Ohm's law, Voltage drop
The relationship that electrical power equals voltage multiplied by current (P = E × I), used to compute load, source capacity, and heat in low-voltage systems.
- Voltage drop
- Related: Ohm's law, Power formula, AWG
The loss of voltage along a conductor caused by its resistance, calculated as 2 × I × R for a two-wire circuit and critical for long low-voltage runs.
- AWG
- Related: Voltage drop, Conduit fill
American Wire Gauge, the standard numbering system for conductor size in which lower numbers indicate larger conductors and lower resistance per unit length.
- Series circuit
- Related: Parallel circuit, Ohm's law
A circuit in which current has one path, so the same current flows through every component and the total resistance equals the sum of individual resistances.
- Parallel circuit
- Related: Series circuit, Ohm's law
A circuit in which components connect across the same two nodes, so voltage is common to all branches and total current is the sum of branch currents.
- Supervisory circuit
- Related: Initiating device circuit, Notification appliance circuit, Class A circuit
A fire alarm circuit that monitors the integrity of wiring and devices, such as initiating device circuits and notification appliance circuits, and signals abnormal conditions.
- Initiating device circuit
- Related: Supervisory circuit, Addressable system
The fire alarm circuit connecting detectors and manual pull stations to the control unit, transmitting alarm signals when a device operates.
- Notification appliance circuit
- Related: Supervisory circuit, Voice evacuation system
The fire alarm circuit that powers horns, strobes, and speakers, delivering the audible and visible signals required by the adopted building and fire codes.
- Addressable system
- Related: Initiating device circuit, Supervisory circuit
A fire alarm architecture in which each device has a unique address, letting the panel report the specific device in alarm or trouble rather than only a zone.
- Class A circuit
- Related: Class B circuit, Supervisory circuit
A fire alarm signaling circuit that continues to operate when a single open or ground fault occurs, because the conductors leave and return to the panel.
- Class B circuit
- Related: Class A circuit, Supervisory circuit
A fire alarm signaling circuit that cannot operate past a single open fault; the panel must then indicate a trouble condition.
- Voice evacuation system
- Related: Notification appliance circuit, Supervisory circuit
An emergency communications system using speakers and intelligible voice messages to direct occupants, often combined with fire alarm notification.
- Equipment grounding conductor
- Related: Bonding jumper, Grounding electrode
The conductor that bonds non-current-carrying metal parts of equipment to the system grounding point, providing a low-impedance path for fault current.
- Bonding jumper
- Related: Equipment grounding conductor, Grounding electrode
A conductor that ensures electrical continuity between metal parts, such as raceways, boxes, and panels, so they remain at the same potential.
- Grounding electrode
- Related: Equipment grounding conductor, Bonding jumper
A conductive object such as a ground rod, plate, or building steel that establishes a direct connection to earth for the grounding system.
- Ground-fault circuit interrupter
- Related: Equipment grounding conductor, Bonding jumper
A device that trips when it detects a small current imbalance between the ungrounded and grounded conductors, protecting people from shock.
- Category cable
- Related: Permanent link, Balanced twisted pair
A twisted-pair cable rated by performance category, such as Cat 5e, Cat 6, or Cat 6A, specifying bandwidth and crosstalk characteristics for data networks.
- Balanced twisted pair
- Related: Category cable, Crosstalk
Two insulated conductors twisted together so that noise couples equally to both, allowing the receiver to reject common-mode interference.
- Crosstalk
- Related: Balanced twisted pair, Category cable
Unwanted signal coupling from one pair or cable to another, measured as near-end or far-end crosstalk and controlled by twist rates and installation practice.
- Permanent link
- Related: Category cable, Crosstalk
The installed portion of a cabling run from the work area outlet to the patch panel, excluding patch cords, and the basis for field certification testing.
- Optical fiber
- Related: Category cable, OFNP cable
A cable that carries data as light through a glass or plastic core, offering high bandwidth and immunity to electromagnetic interference over long distances.
- OFNP cable
- Related: Optical fiber, Plenum
Optical fiber nonconductive plenum cable, rated for air-handling spaces under NEC Article 770 because it has no metallic members and passes NFPA 262.
- Low voltage license
- Related: Qualified individual, Certificate of completion
The North Carolina specialty license that authorizes a qualified individual to contract for low voltage wiring work within the scope defined by state statute and board rules.
- Qualified individual
- Related: Low voltage license, Permit
The person who has passed the licensing examination and is designated as the license holder responsible for the electrical contracting work of a firm.
- Permit
- Related: Qualified individual, Certificate of completion
Written authorization from the local code enforcement jurisdiction to begin work, required before installation and closed out by inspection.
- Certificate of completion
- Related: Permit, Low voltage license
A document, sometimes required by rule, that the installer provides to the owner or authority confirming work was performed and tested as specified.
- Lockout/tagout
- Related: Personal protective equipment, Confined space
A safety procedure that isolates hazardous energy, applies a lock and tag, and verifies de-energization before work begins on equipment.
- Personal protective equipment
- Related: Lockout/tagout, Confined space
Wearable gear such as safety glasses, gloves, hard hats, and arc-rated clothing selected to reduce injury from workplace hazards.
- Confined space
- Related: Lockout/tagout, Personal protective equipment
A space large enough to enter, with limited entry and exit, not designed for continuous occupancy, requiring evaluation and often a permit before entry.