North Carolina Low Voltage Practice · Get comfortable with the vocabulary.

Class 2 circuit

A circuit supplied by a listed Class 2 power source and limited in voltage and power so it presents a low fire and shock hazard, allowing less restrictive wiring methods.

Related: Class 3 circuit, CL3P cable, Power-limited circuit
Class 3 circuit

A circuit supplied by a listed Class 3 power source that is voltage-limited but carries higher current than Class 2, requiring wiring methods closer to those for power circuits.

Related: Class 2 circuit, CL3P cable
Power-limited circuit

A circuit whose energy is capped by a listed power source or overcurrent protection in accordance with its article, reducing fire and shock risk and permitting reduced wiring requirements.

Related: Class 2 circuit, Class 3 circuit, PLTC cable
CL3P cable

A plenum-rated Class 3 cable whose jacket and insulation pass the NFPA 262 Steiner tunnel test, permitting installation in ducts and plenums without conduit.

Related: CMP cable, Plenum, Class 3 circuit
CMP cable

Communications plenum cable tested to NFPA 262, used in air-handling spaces; the "P" suffix marks plenum rating for Articles 800 and 820 cables.

Related: CL3P cable, Plenum, Riser-rated cable
Riser-rated cable

A cable such as CMR or CL3R tested to UL 1666 for flame propagation in vertical shafts, suitable for risers but not for plenums.

Related: CMP cable, Riser, Plenum
Plenum

An air-handling space used for supply, return, or exhaust air, such as a dropped ceiling or raised floor, where only plenum-rated wiring and materials are permitted.

Related: CMP cable, CL3P cable, Riser
Riser

A vertical shaft or penetration connecting floors of a building through which cables run between levels; cable flame ratings for risers are governed by UL 1666.

Related: Riser-rated cable, Firestop
Firestop

A listed material or assembly installed to seal a penetration through a fire-rated wall, floor, or membrane so the fire rating of the barrier is maintained.

Related: Riser, Plenum, Sleeve
Sleeve

A short section of conduit or tubing through a wall or floor that carries cable and protects it from abrasion; a sleeve does not by itself satisfy firestopping requirements.

Related: Firestop, Conduit fill
Conduit fill

The percentage of a raceway's internal cross-sectional area occupied by conductors and cables, limited by NEC Chapter 9 tables to allow pulling and heat dissipation.

Related: Sleeve, J-hook support
J-hook support

A hook-shaped hanger used to support bundles of low-voltage cable at intervals specified by the manufacturer and the applicable article, controlling sag and strain.

Related: Conduit fill, Cable tray
Cable tray

A rigid metal or nonmetallic raceway system with open top used to support and route cables; fill, support, and grounding requirements apply under NEC Article 392.

Related: J-hook support, Equipment grounding conductor
Abandoned cable

Installed cable that is not terminated at equipment and not identified for future use, which Articles 725, 760, 770, 800, and 820 require to be removed or tagged.

Related: Plenum, Riser
Ohm's law

The relationship stating that voltage equals current multiplied by resistance (E = I × R), used to size conductors and predict voltage drop in low-voltage circuits.

Related: Voltage drop, Power formula, Series circuit
Power formula

The relationship that electrical power equals voltage multiplied by current (P = E × I), used to compute load, source capacity, and heat in low-voltage systems.

Related: Ohm's law, Voltage drop
Voltage drop

The loss of voltage along a conductor caused by its resistance, calculated as 2 × I × R for a two-wire circuit and critical for long low-voltage runs.

Related: Ohm's law, Power formula, AWG
AWG

American Wire Gauge, the standard numbering system for conductor size in which lower numbers indicate larger conductors and lower resistance per unit length.

Related: Voltage drop, Conduit fill
Series circuit

A circuit in which current has one path, so the same current flows through every component and the total resistance equals the sum of individual resistances.

Related: Parallel circuit, Ohm's law
Parallel circuit

A circuit in which components connect across the same two nodes, so voltage is common to all branches and total current is the sum of branch currents.

Related: Series circuit, Ohm's law
Supervisory circuit

A fire alarm circuit that monitors the integrity of wiring and devices, such as initiating device circuits and notification appliance circuits, and signals abnormal conditions.

Related: Initiating device circuit, Notification appliance circuit, Class A circuit
Initiating device circuit

The fire alarm circuit connecting detectors and manual pull stations to the control unit, transmitting alarm signals when a device operates.

Related: Supervisory circuit, Addressable system
Notification appliance circuit

The fire alarm circuit that powers horns, strobes, and speakers, delivering the audible and visible signals required by the adopted building and fire codes.

Related: Supervisory circuit, Voice evacuation system
Addressable system

A fire alarm architecture in which each device has a unique address, letting the panel report the specific device in alarm or trouble rather than only a zone.

Related: Initiating device circuit, Supervisory circuit
Class A circuit

A fire alarm signaling circuit that continues to operate when a single open or ground fault occurs, because the conductors leave and return to the panel.

Related: Class B circuit, Supervisory circuit
Class B circuit

A fire alarm signaling circuit that cannot operate past a single open fault; the panel must then indicate a trouble condition.

Related: Class A circuit, Supervisory circuit
Voice evacuation system

An emergency communications system using speakers and intelligible voice messages to direct occupants, often combined with fire alarm notification.

Related: Notification appliance circuit, Supervisory circuit
Equipment grounding conductor

The conductor that bonds non-current-carrying metal parts of equipment to the system grounding point, providing a low-impedance path for fault current.

Related: Bonding jumper, Grounding electrode
Bonding jumper

A conductor that ensures electrical continuity between metal parts, such as raceways, boxes, and panels, so they remain at the same potential.

Related: Equipment grounding conductor, Grounding electrode
Grounding electrode

A conductive object such as a ground rod, plate, or building steel that establishes a direct connection to earth for the grounding system.

Related: Equipment grounding conductor, Bonding jumper
Ground-fault circuit interrupter

A device that trips when it detects a small current imbalance between the ungrounded and grounded conductors, protecting people from shock.

Related: Equipment grounding conductor, Bonding jumper
Category cable

A twisted-pair cable rated by performance category, such as Cat 5e, Cat 6, or Cat 6A, specifying bandwidth and crosstalk characteristics for data networks.

Related: Permanent link, Balanced twisted pair
Balanced twisted pair

Two insulated conductors twisted together so that noise couples equally to both, allowing the receiver to reject common-mode interference.

Related: Category cable, Crosstalk
Crosstalk

Unwanted signal coupling from one pair or cable to another, measured as near-end or far-end crosstalk and controlled by twist rates and installation practice.

Related: Balanced twisted pair, Category cable
Permanent link

The installed portion of a cabling run from the work area outlet to the patch panel, excluding patch cords, and the basis for field certification testing.

Related: Category cable, Crosstalk
Optical fiber

A cable that carries data as light through a glass or plastic core, offering high bandwidth and immunity to electromagnetic interference over long distances.

Related: Category cable, OFNP cable
OFNP cable

Optical fiber nonconductive plenum cable, rated for air-handling spaces under NEC Article 770 because it has no metallic members and passes NFPA 262.

Related: Optical fiber, Plenum
Low voltage license

The North Carolina specialty license that authorizes a qualified individual to contract for low voltage wiring work within the scope defined by state statute and board rules.

Related: Qualified individual, Certificate of completion
Qualified individual

The person who has passed the licensing examination and is designated as the license holder responsible for the electrical contracting work of a firm.

Related: Low voltage license, Permit
Permit

Written authorization from the local code enforcement jurisdiction to begin work, required before installation and closed out by inspection.

Related: Qualified individual, Certificate of completion
Certificate of completion

A document, sometimes required by rule, that the installer provides to the owner or authority confirming work was performed and tested as specified.

Related: Permit, Low voltage license
Lockout/tagout

A safety procedure that isolates hazardous energy, applies a lock and tag, and verifies de-energization before work begins on equipment.

Related: Personal protective equipment, Confined space
Personal protective equipment

Wearable gear such as safety glasses, gloves, hard hats, and arc-rated clothing selected to reduce injury from workplace hazards.

Related: Lockout/tagout, Confined space
Confined space

A space large enough to enter, with limited entry and exit, not designed for continuous occupancy, requiring evaluation and often a permit before entry.

Related: Lockout/tagout, Personal protective equipment