NC Phase W study materials
NC Phase W study resources

Nitrite and Ammonia at a Dead-End Sample Station in a Chloraminated Zone

NC Phase W · Put your knowledge to work in context.

All case studies

Nitrite and Ammonia at a Dead-End Sample Station in a Chloraminated Zone

Your 3.2-MGD system switched to chloramines two years ago to control TTHM. Chlorine and ammonia are fed at the plant to a target of 0.9 mg/L total chlorine leaving the clearwell. In late August, the Merritt Road sample station 3.5 miles out - a dead end past two industrial parks - reads 0.15 mg/L total chlorine, down from 0.5 mg/L in May. Follow-up samples there show 0.45 mg/L free ammonia as N, 0.11 mg/L nitrite as N, and HPC of 380 CFU/mL; two of 40 routine distribution samples in the same pressure zone grew total coliform (non-E. coli). Water temperature is 27 degrees C. The zone is served by a 500,000-gallon elevated tank, 100 feet in diameter, whose level normally swings only 0.8 feet per day; the tank has no mixer and does not overflow. Two dead-end hydrants are blown off about 10,000 gallons a day total, and the last formal flushing program ended in 2023. Fire flow tests in the zone are normal and pressures run 58-72 psi. You are the distribution system operator reviewing the August sampling packet.

1. Diagnose the problem. Why does the ammonia and nitrite pattern point to nitrification rather than simple chloramine decay, and what would you check before accepting the 0.15 mg/L chlorine result at face value?

Read the worked answer

Chloramine decay alone would lower total chlorine and release ammonia, but it cannot produce nitrite. Nitrite is a biological oxidation product, so 0.11 mg/L as N at a dead end is direct evidence that ammonia-oxidizing bacteria are active in the zone. The free ammonia of 0.45 mg/L with only 0.15 mg/L total chlorine is the other half of the signature: the chlorine-to-ammonia ratio at that point is upside down, meaning there is far more ammonia than the residual can tie up, and the residual is being consumed by the biofilm faster than it arrives.

The HPC of 380 CFU/mL and the two total coliform hits fit the same story - biofilm regrowth in a warm (27 degrees C), slow-moving, chloramine-stressed main. Nitrifiers grow in biofilm and sediment, not in the bulk water, which is why the plant can be perfectly on target and the dead end still fails.

Before accepting the chlorine number, check for nitrite interference. Nitrite produces a strong response in the DPD method and can make a low or zero residual read as 0.15 mg/L. Confirm with a diluted sample or an alternative method, and use a monochloramine-specific or indophenol ammonia method rather than a generic kit. Also check sample holding time and whether the bottle was purged properly.

Rule out the ordinary causes too: a partially closed valve, an abandoned service, a dead leg, or a leaking hydrant upstream that is short-circuiting flow.

2. Calculate the tank's effective detention time and explain the role the elevated tank is playing in this problem.

Read the worked answer

Tank cross-sectional area = 0.785 x 100 squared = 7,854 square feet. One vertical foot holds 7,854 x 7.48 = about 58,750 gallons.

Daily swing of 0.8 feet = 0.8 x 58,750 = about 47,000 gallons moving in and out per day. Effective detention = 500,000 / 47,000 = about 10.6 days of average storage time.

That number understates the problem. The daily swing only disturbs the top 0.8 feet of an un-mixed tank; the bulk of the 500,000 gallons below the swing zone is essentially stagnant and may be weeks to months old. Warm, ammonia-containing, chlorine-depleted water sitting at 27 degrees C is a near-perfect nitrifier incubator, and the tank exports that seeded water back into the zone every time the level drops.

A 10-day average age is also long enough on its own to be a problem for chloramine stability and for TTHM formation, and the lack of overflow means nothing ever turns the tank over completely.

The practical fixes are mechanical, not chemical: install a mixer or a tank circulator, widen the operating band so the tank actually cycles, exercise or reset the altitude valve, and if possible take the tank out of service for inspection, sediment removal, and disinfection. No amount of flushing downstream will fix a reservoir that is seeding nitrifiers into the zone.

3. Sequence the corrective actions over the next 30-60 days. Where are the traps?

Read the worked answer

First, confirm the diagnosis: repeat the total coliform samples, verify the chlorine numbers against nitrite interference, and get a nitrite and free ammonia profile at several points between the plant and the dead end so you can see where nitrification begins. That profile usually tells you whether the tank or a specific stretch of main is the reactor.

Short term, within days: unidirectional flush the dead ends and the industrial park loop to strip sediment and biofilm and to restore turnover, and keep the two blow-off hydrants on a scheduled program rather than an occasional one. Verify that all valves feeding the loop are fully open. Increase monitoring frequency at Merritt Road.

Then the real fix: a temporary free chlorine burnout. Stop or reduce ammoniation, raise free chlorine to 1-2 mg/L at the far end, and hold it for two to four weeks while flushing. The tank must be turned over or the burnout will not reach the dead ends - so the mixer or operating-band change needs to happen at the same time, not after.

Traps. Raising the ammonia dose makes nitrification worse, not better. Starting a burnout before the tank is circulating wastes chlorine into the bulk water. Free chlorine will increase TTHM and HAA5 formation, so sample DBPs during the burnout and check against the LRAA. And reseeding happens fast - going back to chloramines too soon restarts the cycle, so plan the return with a free ammonia and nitrite monitoring program and a defined trigger for repeating the burnout.

Finally, plan for the long term: this zone will do the same thing every August without periodic tank turnover and a real flushing program.