Quick reference

Water Treatment

  • Coagulation dose is set by jar test; optimum pH for alum is typically 5.5-6.5, and for ferric chloride roughly 4.5-6.0.

  • Alkalinity consumed by alum: about 0.45 mg/L as CaCO3 per mg/L of alum; add lime if alkalinity drops below ~50 mg/L to protect floc and prevent corrosion.

  • Flocculation design: tapered mixing with velocity gradient G of 10-75 s^-1 and detention time of 15-45 min; rapid mix G is 250-1000 s^-1 for under 30 s.

  • Sedimentation overflow rate: ideal settling velocity v0 = Q/A; particles with settling velocity greater than v0 are removed fully in a rectangular basin of length L, depth H, flow Q.

  • Filtration: slow sand at 0.1-0.4 m/h; rapid gravity at 5-15 m/h. Backwash with 15-25 m/h rise rate until turbidity clears, then filter-to-waste on restart.

  • CT disinfection credit: CT = residual disinfectant concentration (mg/L) x contact time (min); required CT depends on disinfectant, pH, temperature, and log inactivation target.

  • Chlorine demand = applied dose minus residual after contact time; free chlorine residual target at plant effluent is typically 0.5-1.0 mg/L.

  • Hardness removal by lime-soda softening: lime removes carbonate hardness, soda ash removes non-carbonate; practical limit is about 50-80 mg/L as CaCO3.

  • Turbidity limits: combined filter effluent typically 0.3 NTU or less; individual filter must not exceed 1 NTU in 95% of monthly readings.

Quick reference

Water Distribution

  • Minimum residential pressure is typically 20 psi (140 kPa) at ground level under peak demand; normal service pressure is 40-80 psi, and over 100 psi requires pressure-reducing valves.

  • Hazen-Williams head loss: hf = 10.67 x L x Q^1.852 / (C^1.852 x d^4.87) in SI; C is 130-150 for new cement-lined ductile iron, 80-100 for old unlined cast iron.

  • Water hammer pressure surge: change in head = a x change in velocity / g, where a is wave speed (~1000-1400 m/s in metal pipe); close valves slowly to limit surge.

  • Fire flow capacity is checked by a hydrant flow test; available flow at 20 psi residual is estimated from static and residual readings with a pitot gauge and coefficient.

  • Storage sizing: equalization plus fire reserve plus emergency reserve; elevated tanks provide pressure by elevation at about 0.433 psi per foot of head (9.8 kPa per m).

  • Distribution main minimum size is typically 150 mm (6 in) with 200 mm (8 in) preferred for fire flow; dead-end mains should be avoided or flushed.

  • Coliform sampling: at least 5 samples per month for small systems, scaled to population; presence of total coliform triggers repeat samples and investigation for E. coli.

  • Disinfection residual must be maintained throughout distribution; chlorine residual is measured at representative points and must not be undetectable.

Quick reference

Wastewater Collection

  • Design flow is peak wet-weather flow; peak factor commonly 2-4 times average dry-weather flow, and infiltration/inflow must be estimated separately.

  • Self-cleansing velocity in sanitary sewers is at least 0.6 m/s (2 ft/s) at design flow; maximum velocity is about 3 m/s (10 ft/s) to avoid scour.

  • Manning equation for gravity sewers: Q = (1/n) x A x R^(2/3) x S^(1/2); n is 0.013 for vitrified clay and concrete, 0.012-0.013 for PVC.

  • Minimum sewer slope is set by the self-cleansing velocity, not a fixed percent; typical minimums are 0.4-0.5% for 200 mm pipe with design flow checks.

  • Sewer depth of cover minimum is usually 0.9-1.2 m for frost protection; manholes at every change of grade, size, or alignment and at spacing of 90-150 m.

  • Surcharge protection: hydraulic grade line must stay below basement floor level; use backwater valves or relief structures where HGL exceeds the ground.

  • Hydrogen sulfide control: H2S forms in anaerobic slime above the waterline; ventilate manholes and dose nitrate or iron salts to control odors and corrosion.

  • Inflow and infiltration: I/I reduction by smoke testing, dye testing, and CCTV inspection; excessive I/I raises treatment cost and can cause sanitary sewer overflows.

Quick reference

Wastewater Treatment

  • BOD5 test: 5-day, 20 C incubation with nitrification inhibitor; seed correction is applied, and depletion should be between 2 mg/L and the residual limit for validity.

  • Activated sludge F/M ratio: 0.2-0.5 kg BOD/kg MLSS-day for conventional; MCRT/SRT controls sludge age, typically 5-15 days for conventional and 15-30 for nitrification.

  • Sludge volume index SVI = (settled sludge volume mL/L after 30 min) x 1000 / MLSS mg/L; SVI of 80-150 indicates good settling, above 200 indicates bulking.

  • Nitrification requires SRT long enough for slow-growing nitrifiers, dissolved oxygen above 2 mg/L, alkalinity about 7.1 mg as CaCO3 per mg NH3-N oxidized, and temperature above 10 C.

  • Denitrification consumes about 2.86 mg BOD per mg nitrate-N reduced; anoxic zone with carbon source and low DO, recycle ratio of 2-4 times influent.

  • Secondary clarifier overflow rate for activated sludge is 16-32 m3/m2-day at average flow; solids loading rate is 4-6 kg/m2-h; check both.

  • Chlorine disinfection of effluent: dose minus demand gives residual; CT approach applies, and dechlorination with sulfur dioxide protects receiving water.

  • Anaerobic digestion: mesophilic 30-38 C, thermophilic 50-57 C; volatile solids destruction is 40-60%, and gas is about 60-65% methane.

  • Biosolids land application is limited by pathogen reduction and vector attraction reduction; Class B requires site restrictions, Class A allows broader use.