NC Phase W flashcards
NC Phase W · Build recall with a focused review session.
31 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Coagulation optimum pH
- Alum works best around pH 5.5-6.5, while ferric salts function roughly at pH 4.5-6.0. Jar testing confirms the dose and pH where turbidity removal is best.
- Alkalinity consumed by alum
- About 0.45 mg/L of alkalinity as CaCO3 is destroyed per mg/L of alum applied. If alkalinity falls too low, floc formation fails and lime must be added.
- Velocity gradient G
- G measures mixing intensity in coagulation and flocculation. Rapid mix uses roughly 250-1000 s^-1 for seconds; flocculation tapers from about 75 down to 10 s^-1 over 15-45 minutes.
- Overflow rate
- Overflow rate equals flow divided by basin surface area and represents the settling velocity of the slowest particle fully removed. Larger area lowers overflow rate and improves removal.
- CT concept
- CT is disinfectant residual concentration in mg/L multiplied by contact time in minutes. Required CT rises with higher pH, lower temperature, and greater target log inactivation.
- Chlorine demand
- Chlorine demand is the difference between the applied dose and the residual measured after the contact period. It reflects consumption by organics, ammonia, and reduced compounds.
- Lime-soda softening
- Lime removes carbonate hardness and soda ash removes non-carbonate hardness. Practical softening stops around 50-80 mg/L as CaCO3 because of solubility limits.
- Filter effluent turbidity
- Combined filter effluent is typically held to 0.3 NTU or less, and individual filters must stay below 1 NTU in at least 95 percent of monthly measurements.
- Minimum distribution pressure
- Residential service should maintain at least 20 psi at ground level under peak demand. Normal pressure is 40-80 psi, and above 100 psi needs pressure reduction.
- Hazen-Williams C factor
- The C factor describes pipe roughness. New cement-lined ductile iron is about 130-150, while old unlined cast iron drops to 80-100, raising head loss.
- Water hammer surge
- Sudden velocity change creates a pressure surge equal to wave speed times velocity change divided by gravity. Slow valve closure limits the surge magnitude.
- Hydrant flow test
- A flow test records static pressure, residual pressure while flowing, and pitot pressure at the nozzle. These values estimate available fire flow at a chosen residual such as 20 psi.
- Pressure per foot of head
- One foot of water column produces about 0.433 psi, and one meter produces about 9.8 kPa. Tank elevation therefore sets the pressure available in the system.
- Coliform monitoring
- Small systems collect at least five routine coliform samples monthly, scaled upward with population. Any positive sample triggers repeat sampling and investigation for E. coli.
- Distribution chlorine residual
- A detectable disinfectant residual must persist throughout the distribution system. Operators measure free chlorine at representative points to confirm protection against regrowth.
- Peak wet-weather flow
- Collection systems are sized for peak wet-weather flow, often 2-4 times average dry-weather flow. Infiltration and inflow are estimated separately and added to the design flow.
- Self-cleansing velocity
- Sanitary sewers should reach at least 0.6 m/s at design flow to keep solids moving. Velocities above roughly 3 m/s risk scour and pipe damage.
- Manning equation
- Gravity sewer capacity follows Q = (1/n) A R^(2/3) S^(1/2). Roughness n is about 0.013 for concrete and clay and about 0.012 for PVC.
- Sewer minimum slope
- Minimum slope is whatever achieves self-cleansing velocity at design flow, not a fixed percentage. A common starting point is 0.4-0.5 percent for 200 mm pipe.
- Manhole spacing
- Manholes are placed at every change in grade, size, or alignment and at intervals of roughly 90-150 m. They provide access for cleaning and inspection.
- Hydrogen sulfide corrosion
- H2S forms in anaerobic slime above the waterline and oxidizes to sulfuric acid on concrete. Ventilation and chemical dosing control odors and crown corrosion.
- Inflow and infiltration
- I/I is storm water and groundwater entering the sewer. Smoke testing, dye testing, and CCTV locate defects, and reducing I/I lowers treatment cost and overflow risk.
- BOD5 test conditions
- The BOD5 test incubates a seeded sample at 20 C for five days with a nitrification inhibitor. Depletion must fall within the valid range for the result to count.
- F/M ratio
- Food-to-microorganism ratio is BOD mass applied per day divided by MLSS mass. Conventional activated sludge runs about 0.2-0.5 kg BOD per kg MLSS per day.
- Sludge volume index
- SVI equals settled sludge volume in mL/L after 30 minutes times 1000 divided by MLSS in mg/L. Values of 80-150 settle well; above 200 indicates bulking.
- Nitrification requirements
- Nitrifiers need long solids retention time, dissolved oxygen above 2 mg/L, temperature above 10 C, and about 7.1 mg/L alkalinity as CaCO3 per mg/L ammonia oxidized.
- Denitrification carbon demand
- Reducing one mg of nitrate nitrogen consumes about 2.86 mg of BOD. An anoxic zone with recycled nitrified mixed liquor and a carbon source drives the reaction.
- Secondary clarifier loading
- Activated sludge clarifiers are checked on both overflow rate and solids loading. Typical overflow rate is 16-32 m3/m2-day and solids loading 4-6 kg/m2-h.
- Effluent dechlorination
- Sulfur dioxide or sulfite salts neutralize excess chlorine after disinfection. Dechlorination protects aquatic life in the receiving stream from chlorine toxicity.
- Anaerobic digestion
- Mesophilic digestion runs at 30-38 C and thermophilic at 50-57 C. Volatile solids destruction is 40-60 percent and biogas is roughly 60-65 percent methane.
- Biosolids classes
- Class A biosolids meet strict pathogen limits and allow broad land application. Class B meets lesser limits but requires site access restrictions and harvesting setbacks.