NCCER Boilermaker flashcards
NCCER Boilermaker · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Lockout/Tagout Zero Energy
- Lockout/tagout isolates and locks every energy source, then verifies a zero-energy state before work begins, preventing accidental startup or release of stored hydraulic, pneumatic, or steam energy.
- Confined Space Oxygen Range
- Acceptable entry atmosphere requires oxygen between 19.5 and 23.5 percent; levels below or above that range create asphyxiation or flammability hazards and require ventilation or supplied air.
- OSHA Trench Spoils Rule
- Spoil piles, tools, and materials must be kept at least two feet back from the trench edge; trenches five feet deep or more require a protective system such as sloping, shoring, or a trench box.
- Grinding Wheel RPM Rating
- A grinding wheel's marked maximum speed must equal or exceed the grinder spindle speed; overspeed can burst the wheel, so the guard must be in place and the tool rest set close.
- Fire Watch Duration
- A fire watch is maintained during hot work and for at least 30 minutes after the work ends, checking for smoldering sparks and hidden fires in adjacent combustibles.
- Ladder 4-to-1 Rule
- For every four feet of working height, the ladder base sits one foot from the wall, giving roughly a 75 degree angle that keeps the ladder from tipping backward.
- Neutral Flame
- A neutral flame shows one distinct inner cone and is used for cutting steel and welding mild steel; excess oxygen gives a short sharp cone and excess acetylene a feathered three-part flame.
- Acetylene 15 psi Limit
- Free acetylene is unstable and can decompose explosively above about 15 psi gauge, so regulators and manifolds are never set higher and copper tubing is never used with acetylene.
- Oxygen Hose Fittings
- Oxygen hose is green with right-hand threads and fuel gas hose is red with left-hand threads, so the fittings cannot be cross-connected; oil and grease must never contact oxygen equipment.
- E7018 Electrode Meaning
- E marks an electrode, 70 means 70,000 psi minimum tensile strength, 1 means all positions, and 8 means a low-hydrogen iron-powder coating that must be kept in a heated rod oven.
- Standard V-Groove Bevel
- A standard single-V groove uses a 37.5 degree bevel on each plate, producing a 75 degree included angle, usually with a small root face and root opening.
- Cutting Oxygen Purity
- Oxyfuel cutting needs oxygen of at least 99.5 percent purity; lower purity slows the oxidation reaction, leaves ragged kerf edges, and increases slag and cutting time.
- Backfire Versus Flashback
- A backfire is a momentary pop as the flame goes out at the tip; a flashback is flame traveling back into the hose or regulator and requires shutting off the oxygen valve first.
- Third-Angle Projection
- In third-angle projection the top view sits above the front view and the right-side view sits to the right of the front view, matching projection onto a glass box.
- Drawing Scale 1/4 Inch
- A quarter inch equals one foot scale means one quarter inch on the print represents twelve inches actual, so any measured length is multiplied by 48 to get real size.
- Circumference Formula
- Circumference equals pi times diameter, C = 3.1416 D; it gives the flat pattern length when a shell is rolled from plate using the mean diameter.
- Mean Diameter Rolling
- Rolling layout uses the mean diameter, outside diameter minus one plate thickness, so a rolled ring finishes at the specified outside diameter after the ends are welded.
- Hidden Line Convention
- Hidden edges are drawn as medium-weight short dashes, center lines as thin long-short-long lines, and visible outlines as heavy solid lines so the drawing reads consistently.
- Bend Allowance Formula
- Bend allowance equals 0.01745 times the bend angle in degrees times the sum of the inside radius plus half the plate thickness, giving the neutral-axis arc length.
- Sling Leg Tension Formula
- For a two-leg sling, tension per leg equals the load divided by twice the sine of the leg angle from horizontal, so flatter slings carry far more tension.
- Sling Angle Factor
- At 60 degrees from horizontal each leg carries about 0.577 times the load, at 45 degrees about 0.707 times, and at 30 degrees a full 1.0 times the load.
- Wire Rope Safety Factor
- Wire rope slings use a 5-to-1 design factor, so the working load limit is one fifth of the nominal breaking strength of the assembly.
- Shackle Side Loading
- Shackles must be loaded along the centerline from bow to pin; side loading cuts capacity sharply, and screw pins must be fully seated and secured against backing out.
- Hook Removal Criteria
- Remove a hook from service when its throat opening has increased more than 15 percent, wear exceeds 10 percent of the original dimension, or cracks or twists are found.
- Center of Gravity Below Hook
- The hook must hang directly above the load's center of gravity so the load hangs level; an off-center hook causes swinging and uneven loading of the sling legs.
- Chain Sling Design Factor
- Alloy chain slings are designed with a 4-to-1 factor; grade 80 or grade 100 chain is standard, and stretched, gouged, or worn links require removal from service.
- Fire-Tube Boiler
- In a fire-tube boiler hot combustion gases pass through tubes surrounded by water, giving a large water volume and steady low-pressure heating service.
- Water-Tube Boiler
- In a water-tube boiler water circulates inside tubes surrounded by hot gases, permitting higher pressures and much faster steam response than fire-tube designs.
- Hydrostatic Test Pressure
- New power boiler construction is hydrostatically tested at one and one-half times the maximum allowable working pressure while the shell, tubes, and all joints are inspected for leaks.
- ASME Section VIII
- ASME Section VIII governs pressure vessel design and fabrication, Section I covers power boilers, and Section IX covers welding procedure and welder performance qualification.
- Counterflow Heat Exchanger
- Counterflow exchangers pass the hot and cold fluids in opposite directions, producing the largest mean temperature difference and the highest effectiveness per unit of surface area.
- Economizer Function
- An economizer uses flue gas leaving the boiler to preheat incoming feedwater, lowering stack temperature and recovering sensible heat to raise overall boiler efficiency.