Mistake 1

On fall-protection questions, the candidate picks one number for every situation - usually 6 ft - whether the question is about an open-sided walking/working surface (6 ft), a scaffold platform (guardrails at 10 ft), a fixed ladder (24 ft), or steel erection (15 ft).

OSHA 1926 uses a different trigger height in each subpart, and most candidates memorize only the general-industry 6-ft rule because it is the one repeated on every safety orientation.

What to do instead

Build a single drill card listing each trigger height next to the structure it applies to, and practice sorting 15 mixed stems into the right subpart before answering. Answer the structure first, then the height.

Mistake 2

Treats holding the trigger down while bump-firing a pneumatic nailer as normal practice, and describes clearing a jammed nailer without first disconnecting the air line and bleeding residual pressure.

Bump-nailing with the trigger held is a real production shortcut on the job, so the answer feels familiar and 'efficient' rather than unsafe.

What to do instead

Memorize the two hard rules the exam tests: on a contact-actuation tool the trigger is squeezed once per fastener (never held), and every jam or service is preceded by disconnecting the air supply and relieving pressure. On any 'most correct' tool item, disqualify the answer that saves time.

Mistake 3

Answers print-reading items by measuring the drawing with a scale, or by reading a dimension string from the wrong end, instead of using the written dimension; also confuses plan, elevation, and section views when locating a feature.

Hands-on candidates are used to scaling off a set of plans on a tailgate, and full-size drawings shrink when reproduced in a booklet.

What to do instead

Adopt a rule: written dimensions govern, scale is only for un-dimensioned features. Trace each dimension string end-to-end and check that the running dimensions add up to the overall dimension. Before answering, name the view you are reading out loud.

Mistake 4

Sets batter boards and string lines directly on the building line, then squares the corners by eyeball or by measuring only one diagonal, with no offset line left for the excavator.

The candidate remembers 'set batter boards' as a vocabulary answer and skips the why - that the building line has to survive excavation and that a rectangle is only square when both diagonals match.

What to do instead

Answer with the full procedure: establish an offset line a set distance (commonly 2 to 3 ft) outside the building line, drive batter boards, transfer the line to them, and verify square with the 3-4-5 method and by comparing both diagonals to each other. Add concrete form thickness when converting from footing to finished concrete.

Mistake 5

Computes stud length as the wall height minus one plate, or uses the plate deduction for a single top plate when the plans call for a double top plate.

The candidate remembers 'subtract the plates' but not that the deduction is the total thickness of every plate in the assembly, and forgets that nominal 2x material is actually 1-1/2 in. thick.

What to do instead

Work the arithmetic longhand every time: stud length = wall height − (bottom plate + all top plates), using 1-1/2 in. per 2x plate. A standard wall with one bottom and two top plates deducts 4-1/2 in.

Mistake 6

Lays out studs starting flush at a corner and marks every 16 in. from that point, so the studs land on edges rather than centers; also neglects to lay out and mark both sides of every opening and to size the header for the span.

Sixteen inches is remembered as an edge-to-edge measurement, yet the code and sheathing modules are driven by 16 in. on center.

What to do instead

Establish the layout from the corner with the first stud offset so that succeeding studs fall on 16 in. centers, mark both sides of each rough opening, and check header size against the span table rather than reusing whatever is on the truck.

Mistake 7

Uses the total building span as the run when calculating a common rafter, and/or forgets to shorten the rafter by half the thickness of the ridge.

Span and run are used loosely on the job, and the ridge deduction is the step most often done by eye at the ridge rather than in the math.

What to do instead

Before any rafter math, write down: run = half the span, then rafter length per foot of run from the unit rise, then subtract half the ridge thickness for the line length. Check the answer against the framing square step-off.

Mistake 8

Calculates hip and valley rafters with the common-rafter length per foot of run instead of the hip/valley constant, and computes jack rafters from the common-rafter difference rather than the side-cut/hip difference.

Candidates learn the common rafter first, and the 17-on-the-square hip/valley multiplier is a separate memorized constant that gets dropped under time pressure.

What to do instead

Drill the constants as a set: common rafter = unit rise on the tongue, 12 on the blade; hip/valley = 17 on the tongue, unit rise on the blade; jack rafters shorten by the common difference along the plate. Say the constant out loud before computing.

Mistake 9

Orders or frames a door or window rough opening to the unit size, or to the unit size plus framing only, without adding the allowance for the jamb/frame and shim space.

The door is the number printed on the plans, so the rough opening is assumed to match it.

What to do instead

Use the standard framing allowance and state it with the answer: rough opening = unit width + 2 in. (1 in. per side) and height + 2-1/2 in. If a specific manufacturer's frame is given, use that frame's listed rough opening instead of the rule of thumb.

Mistake 10

Shims a door frame only at the hinge side or only at the head, then checks the door swing by eye instead of plumbing the jambs and comparing the head and sill diagonals.

Setting a door that 'closes fine' feels like success, and shimming is tedious, so the frame gets tacked and trusted.

What to do instead

State the full sequence: set the unit in the opening with the sill level, shim behind each hinge, at the lock side, and at the head, then verify plumb on both jambs and equal diagonals before driving the finish fasteners through the shims.