NCCER Glazier flashcards
NCCER Glazier · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Annealed glass
- Standard flat glass cooled slowly with low surface compression. It breaks into large sharp shards, so it cannot be used where safety glazing is required.
- Tempered glass
- Glass heated and rapidly cooled to create surface compression of 10,000 psi or more. It breaks into small dice-like fragments and cannot be cut or drilled after tempering.
- Heat-strengthened glass
- Glass with surface compression around 3,500 to 7,500 psi. It resists thermal stress better than annealed glass but breaks into larger pieces than tempered glass.
- Laminated glass
- Two or more glass lites bonded with a PVB or SGP interlayer. It stays in the opening after breakage, and interlayer thickness sets the safety and security rating.
- IGU primary seal
- The polyisobutylene seal around the perimeter of an insulating glass unit. It blocks moisture vapor entry, while the secondary seal provides structural strength.
- Low-E soft coat
- A sputtered coating applied to a surface inside an IGU. It is fragile and must face the air space, unlike durable hard-coat pyrolytic coatings.
- Safety glazing locations
- Hazardous locations include glazing within 24 inches of a door edge, under 18 inches above the floor, and in bathrooms and stairways.
- Fall protection threshold
- OSHA requires fall protection at 4 feet in general industry and 6 feet in construction. Guardrails have a 42-inch top rail and a midrail.
- Glass weight formula
- Weight in pounds equals area in square feet times thickness in inches times 13.0. One-quarter-inch glass weighs about 3.25 pounds per square foot.
- Ladder angle rule
- Set ladders at a 4:1 ratio, one foot out for every four feet up, and extend three feet above the landing. Secure top and bottom before climbing.
- Cut-resistant gloves
- Gloves rated ANSI/ISEA 105 level A4 or higher are used for handling cut glass. Safety glasses with side shields are required as well.
- Waste glass disposal
- Broken glass goes into a rigid, labeled container, never a trash bag or open bin. It is never compacted by hand because shards cause cuts.
- Storefront system size
- Storefront members are typically 1-3/4 by 4-1/2 inches nominal tube, designed for heights up to about 10 feet. Taller walls use curtain wall.
- Curtain wall definition
- A non-load-bearing envelope hung from the structure that carries only its own weight and wind load. It is not a structural frame.
- Frame deflection limit
- Glazing frames are commonly limited to L/175 for spans up to 13 feet 6 inches, and L/240 plus 1/4 inch for longer spans.
- Glass bite
- The depth the glass edge engages the frame, typically 1/2 to 3/4 inch in wet-glazed storefront. Insufficient bite causes edge loading and breakage.
- Setting block location
- Blocks are placed at the quarter points, each about one-quarter of the lite width from the edge, not at the corners, to support weight and allow movement.
- Dry versus wet glazing
- Dry glazing uses a compression gasket pressed into the frame. Wet glazing uses sealant or glazing tape, and the two are not interchangeable.
- Glazing tape compression
- Closed-cell PVC or butyl tape must be compressed 25 to 30 percent of its thickness to seal. Under-compression is a common cause of leaks.
- Structural silicone bite
- The bond depth of structural silicone is calculated from design wind load. It is at least 1/4 inch and never less than the joint width.
- Vacuum lifter safety factor
- Lifter capacity must exceed the lite weight by a safety factor of two or more. Verify pad seal and gauge reading before lifting.
- Sealant joint ratio
- Joint width is at least 1/4 inch and depth at least 1/4 inch. Depth-to-width is 1:1 up to 1/2 inch wide, then 1:2 for wider joints.
- Backer rod purpose
- Closed-cell polyethylene rod sets sealant depth and prevents three-sided adhesion. Sealant bonds only to the two faces, never the joint back.
- Sealant movement capability
- Silicone handles plus or minus 50 percent movement, polyurethane 25 percent, and acrylic 12.5 percent. Match sealant to calculated joint movement.
- Sealant cure rate
- Silicone skins in 10 to 30 minutes and cures at roughly 1/8 inch per 24 hours. Do not water-test or clean until fully cured.
- Weep hole spacing
- Drained-and-vented systems need weeps at the sill at manufacturer spacing, commonly 12 to 24 inches, kept clear of sealant and debris.
- AAMA 501.2 water test
- A field water test that sprays at 5 gallons per hour per nozzle for at least 5 minutes. Failure shows water at the interior face.
- Fire-protective glazing
- Glazing that blocks smoke and flame but not radiant heat. Fire-resistive glazing also limits temperature rise and is required in some rated walls.
- Sill flashing laps
- Upper flashing laps over lower, side flashing laps over the sill pan, and the sill pan laps over the building wrap, so water drains outward.
- Score-and-break cutting
- A glass cutter scores the surface and the break follows the score. This applies only to annealed glass; tempered and laminated glass cannot be field-cut.
- Glass storage angle
- Lites are stored on an A-frame rack at 5 to 10 degrees from vertical, never flat or leaning, with the bottom edge on a soft pad.
- ASTM E1300
- The standard that gives load resistance of glass based on type, thickness, area, aspect ratio, and load duration. It is used to select thickness.