- Scope of ECG technician
- Technicians perform ECG recordings and basic rhythm recognition but do not interpret or diagnose; they report findings to a physician or supervising clinician.
- Critical rhythm escalation
- If a life-threatening rhythm such as ventricular fibrillation or asystole is seen, the technician must immediately alert the care team and initiate emergency response per protocol.
- Infection control duty
- Technicians must perform hand hygiene and clean reusable electrodes between patients to prevent cross-contamination.
- Patient education role
- Explaining the ECG procedure and reassuring the patient is within the technician's scope; obtaining informed consent is typically the physician's responsibility.
- Documentation responsibility
- Technicians document the procedure, patient response, and any artifacts; accurate documentation is essential for patient care and legal record.
- V1 electrode placement
- V1 is placed at the fourth intercostal space at the right sternal border.
- V4 electrode placement
- V4 is placed at the fifth intercostal space at the midclavicular line.
- Limb electrode placement
- Limb electrodes are placed on the right arm, left arm, right leg, and left leg, avoiding bony prominences and joints.
- Skin preparation
- Clean the skin with alcohol and dry it; shave excessive hair if needed to reduce artifact and ensure good electrode contact.
- Patient positioning
- Position the patient supine or semi-recumbent with limbs relaxed and supported to minimize muscle artifact during the ECG recording.
- Standard paper speed
- The standard ECG paper speed is 25 mm/s, which means one small box is 0.04 seconds and one large box is 0.20 seconds.
- Standard gain setting
- The standard gain is 10 mm/mV, meaning a 1 mV signal produces a 10 mm deflection on the ECG paper.
- Calibration pulse check
- A calibration pulse should be 10 mm high and 0.2 seconds wide at standard settings, confirming proper gain and paper speed.
- Baseline wander cause
- Baseline wander is often caused by respiration or patient movement; it can be reduced by having the patient relax and hold still.
- AC interference
- 60 Hz electrical interference appears as a thick, fuzzy baseline; check electrode contact, cable connections, and nearby electrical equipment.
- Somatic tremor artifact
- Muscle tremor causes irregular, spiky artifact; help the patient relax and support the limbs to minimize it.
- Troubleshooting loose electrode
- If an electrode is loose or dried out, replace it and re-prep the skin; poor contact causes artifact and false readings.
- Rhythm strip length
- Record at least a 10-second rhythm strip, usually lead II, to assess rhythm and rate accurately.
- Normal sinus rhythm criteria
- Normal sinus rhythm has a rate of 60-100 bpm, regular rhythm, P wave before every QRS, PR interval 0.12-0.20 s, and QRS <0.12 s.
- Sinus bradycardia
- Sinus bradycardia is a sinus rhythm with a rate below 60 bpm; it may be normal in athletes or caused by medications.
- Sinus tachycardia
- Sinus tachycardia is a sinus rhythm with a rate above 100 bpm; common causes include fever, pain, anxiety, and exercise.
- Atrial fibrillation characteristics
- Atrial fibrillation is an irregularly irregular rhythm with absent P waves and a fibrillatory baseline; the ventricular rate varies.
- Ventricular tachycardia
- Ventricular tachycardia has wide QRS complexes (>0.12 s) and a rate typically >100 bpm; it is a medical emergency if pulseless.
- Ventricular fibrillation
- Ventricular fibrillation is a chaotic, irregular waveform with no identifiable QRS complexes; immediate defibrillation is required.
- Asystole confirmation
- Asystole appears as a flat line; confirm that leads are connected properly and gain is set correctly before declaring asystole.
- Heart rate calculation
- Calculate heart rate by dividing 300 by the number of large boxes between R waves, or 1500 by the number of small boxes.
- Strip labeling requirements
- Each ECG strip must be labeled with patient name, date, time, lead, and any symptoms or interventions for accurate identification.
- SBAR communication
- SBAR (Situation, Background, Assessment, Recommendation) is a structured method for reporting changes in patient condition to clinicians.
- Critical value reporting
- Report critical ECG findings such as new ST elevation or ventricular arrhythmias immediately to the responsible clinician per facility protocol.
- Documenting patient symptoms
- Record any symptoms (chest pain, palpitations, dyspnea) and vital signs at the time of the ECG to correlate with findings.
- Interventions documentation
- Note any interventions (oxygen, medication) and the patient's response in the medical record to provide a complete clinical picture.
- Patient identification
- Verify patient identification using at least two identifiers before reporting ECG results to prevent miscommunication and ensure patient safety.