NEBOSH Fire Safety flashcards
NEBOSH Fire Safety · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Responsible person
- The individual or organisation legally responsible under fire safety law for the premises, including carrying out or arranging the fire risk assessment and implementing preventive and protective measures.
- Suitable and sufficient assessment
- A fire risk assessment that identifies all significant hazards, evaluates risk to relevant persons, and records control measures proportionate to the risk, without necessarily being perfect or exhaustive.
- Prohibition notice
- A notice issued by an enforcing authority where fire risk is so serious that use of premises involves risk of serious personal injury, restricting or prohibiting that use until remedied.
- Enforcement notice
- A formal notice requiring the responsible person to remedy a failure to comply with fire safety duties within a specified period, with appeal rights to a tribunal or court.
- Competent person
- A person with sufficient training, experience, knowledge and other qualities, supported by adequate resources, to undertake the fire safety task assigned to them.
- Plan-Do-Check-Act
- A four-stage management cycle: establish policy and planning, implement controls, monitor and measure performance, then review and correct, forming the basis of fire safety management systems.
- Fire safety policy
- A written statement of intent and commitment by senior management setting out how fire safety will be managed, who is accountable, and the standards expected across the organisation.
- Review trigger
- An event requiring the fire risk assessment to be revisited: change of use, new process or plant, building works, change in occupants, a fire incident, or passage of time.
- Risk rating formula
- A qualitative risk score obtained by multiplying a likelihood rating by a severity rating, then banded to prioritise which hazards need action first.
- Fire triangle
- The three elements needed for combustion: fuel, oxygen and heat. Removing any one of them extinguishes or prevents fire.
- Fire tetrahedron
- An extension of the fire triangle adding the chemical chain reaction, explaining why agents such as halon replacements and dry powder interrupt combustion chemically as well as by cooling.
- Residual risk
- The level of risk remaining after existing and additional control measures have been applied; it must be judged against a tolerance threshold and recorded.
- Dynamic risk assessment
- A short, task-specific assessment made at the point of work, used for non-routine activities such as hot work, where conditions or tasks change frequently.
- Fuel load
- The total quantity of combustible material in a space, expressed as calorific value per unit floor area, which governs fire growth rate, duration and severity.
- Hot work permit
- A formal authorisation for welding, cutting, grinding or other spark-producing work, specifying preparation, fire watch, extinguisher provision and post-work monitoring.
- People at risk
- Persons who may be affected by fire, including employees, visitors, contractors, lone workers, sleeping occupants and those with impaired mobility, hearing or sight.
- Hierarchy of control
- Order of preference for controlling fire risk: eliminate the hazard, substitute or reduce it, then apply engineering and administrative controls and finally PPE.
- Water extinguisher
- A cooling agent suitable for Class A solid combustibles such as wood, paper and textiles; unsafe on live electrical equipment and on flammable liquid or cooking oil fires.
- CO2 extinguisher
- A clean, non-conductive agent for electrical and flammable liquid fires; it starves the fire of oxygen but has limited cooling, so re-ignition is a risk.
- Wet chemical extinguisher
- An agent that saponifies hot cooking oils, forming a soapy blanket, and is the correct choice for Class F kitchen fat and oil fires.
- Sprinkler activation
- Each sprinkler head operates individually when its heat-sensitive element fuses, typically around 68 degrees C, so only heads near the fire discharge water.
- Pre-action sprinkler system
- A dry-pipe system where water is admitted only after a detector confirms fire, protecting water-sensitive areas such as computer rooms and archives from accidental discharge.
- Alarm category L1
- A BS 5839 life protection category requiring detection throughout the building, including all rooms and escape routes, giving the earliest possible warning.
- Alarm category L4
- A BS 5839 life protection category covering only escape routes and circulation areas, suitable where occupants are familiar and fire risk in rooms is low.
- Emergency lighting level
- Minimum illumination on escape route centre lines of 1 lux, and 0.5 lux in open areas, maintained for the rated duration when normal lighting fails.
- Fire door function
- A fire-resisting door assembly that limits smoke and fire spread between compartments; it must self-close fully and never be wedged or propped open.
- Travel distance
- The maximum distance a person must travel from any point to a place of relative safety, limited by occupancy, use and whether the escape route is single-direction.
- Place of relative safety
- A location such as a protected escape route or compartment where occupants are temporarily safe from fire and smoke while continuing to evacuate.
- Protected escape route
- An escape route enclosed by fire-resisting construction, with self-closing fire doors, kept clear of combustibles and not passing through high fire-risk areas.
- Personal emergency evacuation plan
- An individual plan for a person needing assistance to evacuate, specifying who assists, the method, and where they go, agreed in advance and practised.
- Phased evacuation
- An evacuation strategy where occupants nearest the fire leave first, then other areas are evacuated in stages, used in large or high-rise buildings to manage stair capacity.
- Roll call and sweep
- A method of accounting for occupants at the assembly point, combined with a physical sweep of the building to confirm no one remains.