Water tender
A mobile water supply apparatus with a large tank, a fire pump, and a fast dump valve, designed to carry water to a fireground where no pressurized source exists.
Dump valve
A large valve on a water tender that releases tank water rapidly into a portable tank or basin; gradual opening controls surge and splash during unloading.
Portable water tank
A collapsible frame tank set up at a dump site to receive tender dumps and provide a buffer from which a receiving pump draws water for the fireground.
Jet fill
A venturi educator system that uses a pressurized water source to load a tender tank rapidly; it requires a properly sized and clear tank vent.
Baffle
An internal partition in a water tank that limits liquid surge; a failed baffle concentrates momentum and worsens vehicle handling and tank stress.
Free surface effect
The shifting of liquid in a partially filled tank that raises the center of gravity and reduces stability, making partial loads the most hazardous condition.
Shuttle flow formula
Rate in gpm equals total gallons delivered divided by total cycle time in minutes, where cycle time includes fill, loaded travel, dump, and empty travel.
Cycle time
The total elapsed time for one tender to complete a fill, loaded trip, dump, and return trip; reducing it is the primary way to increase shuttle flow.
Usable tank capacity
The volume a tender can actually deliver per trip, less than nominal capacity because of residual water and safe fill limits; use it in shuttle calculations.
Fill site officer
The supervisor who controls tender movement at the water source, assigns fill positions, and prevents collisions and self-dispatching from the queue.
Dump site officer
The supervisor who manages tender spacing, traffic flow, and portable tank use at the unloading point to prevent collisions and cross-flow between tanks.
Water supply officer
The command staff member who manages fill and dump sites, assigns tenders, tracks cycle times, and calculates the sustained flow delivered to the incident.
Relay pumping
A series arrangement in which each engine boosts pressure to the next engine down the line, moving water long distances through large-diameter hose.
Dual pumping
Two engines draft from the same source and discharge into a common manifold or large line; pumps must be balanced to avoid cavitation or overpressurization.
Friction loss formula
FL equals C times Q squared times L, where C depends on hose diameter, Q is flow in hundreds of gpm, and L is hose length in hundreds of feet.
Nozzle flow formula
Q in gpm equals 29.7 times the square of the tip diameter in inches times the square root of nozzle pressure in psi, for a smooth bore tip.
Engine pressure
The pump discharge pressure needed at the engine, equal to nozzle pressure plus friction loss plus elevation change plus appliance loss.
Elevation pressure
A change of 0.5 psi per foot of elevation, added for rise and subtracted for drop, when calculating required pump pressure for a hose layout.
NFA fire flow formula
Needed gpm equals length times width divided by three, times percent involvement, times 100, for a single-story building fire.
Drafting lift limit
The practical vertical distance a pump can lift water, roughly 20 to 25 feet at sea level, reduced by altitude, worn pumps, and leaking suction connections.
Tank-to-pump valve
A valve that admits water from the apparatus tank to the pump; its operation and labeling are checked during readiness inspections and pump shift drills.
Pump shift
The mechanism that changes the drivetrain from road gear to pump gear; it must be tested in and out during readiness checks before the apparatus is relied upon.
Low-air warning
An audible and visual alert that activates at approximately 55 to 60 psi of air brake pressure, warning the driver before brake performance is lost.
Governor cut-out
The air compressor cutoff pressure, typically near 120 to 125 psi, with cut-in near 100 psi; abnormal values indicate an air system fault.
Following distance
A minimum of about four seconds in good conditions, increased with speed and load; a loaded tender needs far more stopping distance than a passenger car.
Liquid surge
The fore-and-aft and side-to-side movement of water in a tank during braking, acceleration, or turning, which destabilizes a heavily loaded tender.
Due regard
The legal standard requiring emergency vehicle operators to drive with reasonable care for others, even when using warning lights and sirens.
Spotter
A crew member positioned behind the apparatus to guide backing, maintaining eye contact with the driver; if contact is lost, the driver stops.
Hard suction hose
A rigid, non-collapsible hose used to draft water from a static source, fitted with a strainer and kept off the bottom to avoid drawing debris.
Large-diameter hose
Hose of 4 to 5 inches used for relay, fill, and supply lines because it carries high flow at much lower friction loss than smaller hose.
Pressure governor
A pump control that maintains a set discharge pressure by adjusting engine speed, protecting the relay from water hammer when downstream demand changes.
Accountability
The system for tracking every crew member at fill sites, dump sites, and the fireground, ensuring supervisors know who is present and where.