Fire tetrahedron
The four components needed for combustion are fuel, oxygen, heat, and an uninhibited chemical chain reaction; removing any one stops the fire.
Flash point
Lowest temperature at which a liquid releases enough vapor to form an ignitable mixture near its surface, but combustion does not continue.
Fire point
Temperature at which a liquid releases vapors fast enough to sustain continuous combustion after ignition; it is slightly higher than the flash point.
Class A fire
Fire involving ordinary combustibles such as wood, paper, cloth, and plastics; water and ABC dry chemical are effective extinguishing agents.
Class B fire
Fire involving flammable or combustible liquids and gases; foam, carbon dioxide, and dry chemical can smother or inhibit combustion.
Class C fire
Fire involving energized electrical equipment; de-energize the circuit when possible, then use a nonconductive extinguishing agent such as carbon dioxide.
Class D fire
Fire involving combustible metals such as magnesium or sodium; use a compatible dry powder and avoid water, which can react violently.
Class K fire
Fire involving cooking oils or fats in commercial cooking equipment; wet chemical agent saponifies the fat and cools the surface.
PASS technique
Extinguisher operation sequence: Pull the pin, Aim at the base of the fire, Squeeze the handle, and Sweep the nozzle side to side.
Four-to-one ladder rule
Place the base of a ground ladder one foot from the building for every four feet of vertical height, producing about a 75-degree angle.
Roof ladder extension
For roof access, extend a ground ladder three to five rungs above the roof edge so firefighters can step safely onto the roof.
Primary search
Rapid, systematic search for victims in the immediate fire area and likely exit paths, often conducted before fire control is complete.
Thermal layering
Hot combustion gases collect at the ceiling while cooler air remains near the floor; firefighters stay low to avoid high heat and smoke.
Backdraft
Explosive ignition of heated, fuel-rich gases when oxygen suddenly enters a confined space; indicators include heavy smoke and inward air movement.
Vertical ventilation
Opening the highest point of a structure while providing a lower inlet; hot smoke and gases escape upward and conditions improve inside.
Water-to-steam expansion
One gallon of water converted to steam expands to about 1,700 gallons, absorbing large amounts of heat from the fire.
Two-in/two-out rule
At least two firefighters enter an IDLH atmosphere together while two trained and equipped firefighters remain outside ready to rescue them.
Incident command system
Standardized management framework using command, operations, planning, logistics, and finance sections to coordinate emergency incidents and resources.
Transfer of command
Formal process in which the incoming incident commander receives a briefing on conditions, actions, resources, and safety before assuming command.
Needed fire flow
Iowa formula estimates required flow as length times width times number of floors, divided by three, in gallons per minute.
Type I construction
Fire-resistive construction with structural members protected from fire, usually providing the highest collapse resistance and longest fire resistance.
Type V construction
Wood-frame construction with combustible walls, floors, and roof; common in residential buildings and prone to rapid fire spread.
Wet-pipe sprinkler system
Automatic sprinkler system with water under pressure in the pipes; each head opens individually when its heat-sensitive element activates.
Dry-pipe sprinkler system
Automatic sprinkler system holding compressed air in the pipes; when a head opens, air escapes and water enters the system.
Deluge sprinkler system
System with open sprinkler heads; activation of the control valve discharges water simultaneously from all heads over the protected area.
Preaction sprinkler system
System using closed heads and a separate detection circuit; water fills the pipes only after detection and then a head opens.
Photoelectric smoke detector
Detector that responds to visible smoke particles by light scattering; it is generally more sensitive to smoldering fires.
Ionization smoke detector
Detector that responds to invisible combustion products using a small radioactive source; it is generally more responsive to flaming fires.
Aqueous film-forming foam
Class B foam that forms a thin aqueous film on hydrocarbon fuels, suppressing vapor and excluding oxygen from the fuel surface.
Positive pressure ventilation
Ventilation method using a blower to force fresh air into a structure while an opposite opening allows smoke and heat to exit.
Rapid intervention team
Standby crew of at least two firefighters with rescue tools, air supply, and search equipment, deployed specifically to rescue trapped firefighters.
Mayday LUNAR report
Distress radio report giving Location, Unit, Name, Assignment, and Resources or air status so rescuers can locate and assist the firefighter.