NGWA CWD flashcards
NGWA CWD · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Annular velocity formula
- In feet per minute, annular velocity equals 24.5 times pump output in gallons per minute divided by the difference between hole diameter squared and pipe diameter squared, both in inches.
- Hydrostatic pressure formula
- Hydrostatic pressure in psi equals 0.433 times the fluid density in pounds per gallon times true vertical depth in feet. It depends on vertical depth, not measured length.
- Hole volume per foot
- Gallons per foot of borehole equals diameter in inches squared divided by 24.5. A 6-inch hole holds about 1.47 gallons per foot.
- Cable tool drilling action
- A heavy bit is repeatedly lifted and dropped to crush formation, and a bailer removes the cuttings. The method works well in unconsolidated sand, gravel, and boulder formations.
- Rotary drilling circulation
- A rotating bit cuts formation while drilling fluid circulates down the drill pipe and up the annulus, carrying cuttings to the surface and cooling the bit.
- Fracture gradient limit
- The pressure at which the formation breaks down and accepts fluid. Mud weight and grout placement pressure must remain below this value to avoid loss of circulation.
- Well development purpose
- Surging, jetting, air lifting, or overpumping removes drilling fines and filter cake from the formation near the screen, restoring permeability and improving yield and water quality.
- Grout volume estimate
- Multiply annular capacity between casing outside diameter and borehole wall by the length to be sealed, then add 10 to 25 percent to allow for washouts and fractures.
- Proper abandonment seal
- The full borehole is sealed with low-permeability material such as neat cement or bentonite grout, plus a surface seal. Backfilling with cuttings is not an acceptable abandonment method.
- Water level measuring point
- Static water level is measured from a surveyed reference, usually top of casing. Adding measuring-point elevation converts depth to water into hydraulic head.
- Casing setting depth
- Casing is set into a competent, low-permeability confining layer so the annulus seal isolates the target aquifer from shallow groundwater and surface contamination.
- Drilling fluid functions
- Fluid cools and lubricates the bit, lifts cuttings, stabilizes the borehole wall by forming filter cake, and controls hydrostatic pressure against formation fluids.
- Screen slot selection
- Slot openings are sized to retain most of the filter pack, commonly keeping 90 to 100 percent of the pack. The pack itself is sized from the formation grain distribution.
- Filter pack sizing rule
- Filter pack grains are typically four to five times the d50 grain size of the formation. The pack must be clean, well rounded, and free of fines.
- Filter pack placement
- The pack extends at least two feet above the top of the screen. A bentonite seal two to five feet thick is placed above the pack and hydrated before grouting.
- Tremie grouting method
- Grout is pumped through a tremie pipe from the bottom of the annulus upward. The discharge end stays submerged in grout to prevent voids, bridging, and dilution.
- Neat cement grout mix
- Neat cement is mixed near 0.4 to 0.5 water-to-cement ratio by weight, roughly six to seven gallons per 94-pound sack, producing a dense, low-permeability seal.
- Monitoring well materials
- Flush-threaded Schedule 40 PVC, stainless steel, or PTFE are common. Solvent-cemented joints are avoided because solvents can contaminate groundwater samples.
- Hydraulic gradient formula
- Gradient equals the head difference between two points divided by the horizontal distance between them. Groundwater flows from higher head toward lower head.
- Darcy velocity
- Darcy velocity equals hydraulic conductivity times hydraulic gradient. Dividing by effective porosity gives average linear seepage velocity, which is faster than Darcy velocity.
- Low-flow purging criteria
- Purging at low flow aims to keep drawdown under 0.1 foot while pH, specific conductance, turbidity, dissolved oxygen, and oxidation-reduction potential stabilize before sampling.
- Equipment decontamination
- Wash with phosphate-free detergent, rinse with tap water, rinse with deionized water, and air-dry. Dedicated or disposable sampling equipment reduces cross-contamination between wells.
- Bentonite seal hydration
- Bentonite pellets or chips are hydrated with clean water before grout is placed above them, so the seal swells and prevents grout from migrating down the annulus.
- Sand content of grout
- Excess sand or fines in cement grout increase permeability and shrinkage. Grout should be mixed from clean water and neat cement unless a specified additive is required.
- Top of screen setting
- The screen is positioned to intersect the target saturated zone, with the top below the expected water table so the screen remains submerged during seasonal low-water conditions.
- Surging and jetting
- Surging moves water back and forth through the screen with a plunger; jetting directs water through the screen. Both flush fines from the filter pack and formation.
- Air-lift development
- Compressed air injected through a eductor pipe lifts water and fines from the well. It is effective in deep wells but can damage weak formations if flow is uncontrolled.
- Well yield test
- A step-drawdown or constant-rate pumping test measures yield and specific capacity. Drawdown and pumping rate are recorded until water levels stabilize.
- Specific capacity
- Specific capacity equals pumping rate divided by drawdown, usually in gallons per minute per foot. Higher values indicate a more productive well and formation.
- Surface seal requirement
- A low-permeability seal from land surface to the first confining layer prevents surface water and shallow contamination from moving down the annulus.
- VOC sample handling
- Samples for volatile organic compounds are collected with minimal agitation, zero headspace, and chilled storage. Field blanks and trip blanks document possible contamination.
- Water level sounder use
- A graduated cable with a conductivity probe is lowered until the probe contacts water and the meter signals. Depth is read from the surveyed top-of-casing reference.