NH Journeyman Plumber study materials
NH Journeyman Plumber study resources

NH Journeyman Plumber cheat sheet

NH Journeyman Plumber · Keep the key ideas within reach.

Quick reference

General Plumbing Knowledge

  • Plumbing is the practice, materials, and fixtures used in installing, maintaining, extending, altering, or repairing piping for water, gas, sewage, and drainage within or adjacent to a building.

  • Water weighs about 62.4 lb per cubic foot; a column of water 1 ft high exerts 0.433 psi, so pressure in psi equals height in feet times 0.433.

  • Fixture unit (FU) values express the probable load of fixtures on supply and drainage systems; 1 FU approximates 1 cubic foot per minute of flow for drainage sizing.

  • A trap seal is maintained by a water depth of 2 to 4 inches; the minimum seal depth is 2 inches and the maximum is 4 inches.

  • Grade for drainage piping: 1/4 inch per foot for pipe 3 inches and smaller; 1/8 inch per foot is permitted for pipe 4 inches and larger where approved.

  • Flow velocity in water supply piping should generally stay below 8 fps in cold water and 5 fps in hot water lines to limit noise and erosion.

  • Common pipe materials: copper (Type L, M, K), PEX, CPVC, PVC, cast iron, and galvanized steel; each has distinct pressure, temperature, and joining limits.

  • Backflow prevention depends on an air gap or a mechanical device selected by hazard level: atmospheric vacuum breaker, pressure vacuum breaker, double check, or reduced pressure zone assembly.

  • A plumbing system has four parts: water supply, fixtures and fixture fittings, drainage, and venting; each must be designed and sized as a coordinated system.

Quick reference

Plumbing Fixtures and Fixture Fittings

  • Water closets are limited to 1.6 gallons per flush (gpf) maximum; high-efficiency models use 1.28 gpf or less.

  • Urinals are limited to 1.0 gpf maximum; waterless urinals use a sealed trap cartridge in place of a water seal.

  • Showerheads are limited to 2.5 gallons per minute (gpm) at 80 psi; kitchen faucets are limited to 2.2 gpm.

  • Lavatory faucets are limited to 2.2 gpm, and public lavatory faucets to 0.5 gpm at 60 psi.

  • Fixture clearances: 15 inches minimum from a water closet centerline to a side wall or partition, and 30 inches minimum clear width for the fixture space.

  • A water closet compartment must be at least 30 inches wide and 60 inches deep when a door is provided, with the door swinging outward.

  • Air gaps for fixture outlets: at least 1 inch or twice the effective opening of the supply fitting, whichever is larger, and never less than 1 inch above the flood-level rim.

  • Floor drains require a trap with a 2-inch minimum seal; trap primers or trap seal protection devices maintain the seal in infrequently used drains.

  • Drinking fountains must have a supply protected by an air gap or a listed backflow preventer, and the orifice must be above the flood-level rim.

Quick reference

Water Heaters and Related Equipment

  • A temperature and pressure relief (T&P) valve is required on every storage water heater; its rated capacity must equal or exceed the heater's input and its setpoint must not exceed 210°F or 150 psi.

  • The T&P relief valve discharge pipe must be full size, gravity-drained, terminate not more than 6 inches above the floor or outside, and never be trapped or reduced.

  • A thermal expansion tank is required on a closed water supply system to absorb expansion from heating; a check valve or backflow preventer creates a closed system.

  • Water heater seismic or thermal expansion control is separate from the T&P valve; the T&P valve protects against overpressure and overheating, not expansion volume.

  • Gas-fired water heaters in garages must have ignition sources elevated at least 18 inches above the floor unless listed as flammable vapor ignition resistant (FVIR).

  • A water heater drain pan is required where leakage could cause damage; the pan must be at least 1.5 inches deep and drained by gravity or a listed pump.

  • Combustion air for gas water heaters: 50 cubic feet per 1,000 Btu/hr input from indoor volume, or two permanent openings to outdoors sized at 1 square inch per 4,000 Btu/hr.

  • Storage water heaters must have the thermostat set no higher than 140°F for scald control; domestic hot water delivered to fixtures should not exceed 120°F at the point of use.

  • Tankless water heaters require minimum flow rates to fire and must be sized by simultaneous fixture demand plus incoming groundwater temperature rise.

Quick reference

Water Supply and Distribution Systems

  • Minimum static pressure at a fixture is 8 psi for flush tanks and 15 psi for flushometer valves; maximum static pressure at any fixture is 80 psi.

  • Where street pressure exceeds 80 psi, a pressure-reducing valve is required; where it is below 8 psi, a booster pump is required.

  • Water service pipe must be buried below the local frost depth; in New Hampshire this is typically 4 to 5 feet depending on location.

  • Sizing uses the demand load in fixture units converted to gallons per minute, then pipe size is selected from tables using developed length and pressure loss.

  • Developed length includes the actual pipe run plus equivalent lengths for fittings; a 90-degree elbow adds about 2 to 5 feet depending on size.

  • A water meter and main shutoff must be accessible; a bypass or full-open valve arrangement allows service without interrupting supply.

  • Hot water distribution should minimize dead legs; recirculation systems or point-of-use heaters reduce wait time and wasted water.

  • Copper Type M is permitted for above-ground domestic water; Type L is used for underground and higher-pressure service.

Quick reference

Sanitary Drainage, Vents, and Storm Drainage

  • Drainage pipe slope: 1/4 inch per foot for 2-inch and smaller; 1/4 inch per foot for 3-inch; 1/8 inch per foot permitted for 4-inch and larger where approved.

  • A horizontal drainage branch must be vented; the trap arm length from fixture trap to vent is limited by pipe size (e.g., 1-1/2 inch pipe = 6 feet, 2 inch pipe = 8 feet, 3 inch pipe = 12 feet).

  • A vent stack must extend at least 6 inches above the roof and not less than 12 inches above the roof where the roof is used for other purposes.

  • Vent terminals must be at least 10 feet from any window, door, or air intake, and at least 3 feet above a roof within 10 feet of the vent.

  • A building drain is the lowest piping that receives the discharge from soil and waste stacks inside the building; it connects to the building sewer at least 2 feet outside the foundation.

  • A cleanout is required at the base of each soil or waste stack, at the building drain, and at intervals not exceeding 100 feet in horizontal runs.

  • Storm drainage must be separate from sanitary drainage; roof drains and area drains cannot connect to the sanitary sewer unless the system is a combined sewer.

  • A backwater valve is required on drainage fixtures installed below the elevation of the next upstream manhole or where the building drain is subject to backflow.

  • Vent pipe sizing depends on fixture units and developed length; an undersized vent causes gurgling, slow drains, and trap seal loss.

Quick reference

Fuel Gas Piping and Gas Appliances

  • Gas piping must be sized by the longest length method or branch length method using the total Btu/hr input of connected appliances and the allowable pressure drop.

  • Natural gas is supplied at about 1,000 Btu per cubic foot; LP gas is about 2,500 Btu per cubic foot, so pipe sizing differs by fuel type.

  • A gas shutoff valve must be installed within 6 feet of each appliance and in the same room; a union or flanged connection allows appliance removal.

  • Sediment traps (drip legs) are required at each appliance unless the appliance is designed without one; the trap must be downstream of the shutoff valve.

  • Gas piping must be tested at 1.5 times the working pressure but not less than 3 psi for 10 minutes for low-pressure systems; higher-pressure systems require longer tests.

  • A gas appliance connector must not exceed 6 feet in length, must not pass through walls or floors, and must not be concealed.

  • Combustion air and venting for gas appliances: Category I appliances use natural draft venting; Category IV condensing appliances use direct venting with PVC or CPVC.

  • Gas piping must not be installed in a concealed location without protection, and it must not pass through a chimney, elevator shaft, or duct.

  • A gas leak test uses air or inert gas, never oxygen; a soap bubble solution or electronic detector locates leaks after isolation.

Quick reference

New Hampshire Plumbing Code, Statutes, and Rules

  • New Hampshire adopts the International Plumbing Code (IPC) as the state plumbing code, with amendments published in the New Hampshire Administrative Rules, Chapter Plc 300.

  • Plumbing work in New Hampshire requires a license issued by the Office of Professional Licensure and Certification (OPLC) under RSA 329-A.

  • A journeyman plumber license requires documented experience (typically 4 years) and passage of the journeyman examination; a master plumber license requires additional experience and examination.

  • Licenses must be renewed on a biennial cycle; continuing education hours are required for renewal and must be documented.

  • A plumbing permit must be obtained from the local authority having jurisdiction before work begins; emergency repairs may be permitted with follow-up inspection.

  • The state plumbing code applies to new construction, alterations, and repairs; existing installations that are not hazardous may remain in service.

  • Inspections are performed by local or state plumbing inspectors; work must be accessible for inspection before concealment.

  • Unlicensed plumbing work is subject to enforcement, fines, and permit revocation; homeowners may perform work only on their own residence where local rules allow.

  • Adopted code editions and amendments are published by the New Hampshire OPLC and take effect on the date specified in the rule; the most current edition governs.

Quick reference

General Plumbing Knowledge

  • Water pressure conversion: psi = feet of head × 0.433; feet of head = psi ÷ 0.433.

  • Fixture unit values represent probable flow; drainage and supply sizing tables use FU as the common basis.

  • Trap seal depth must be 2 to 4 inches; seals protect against sewer gas entry.

  • Backflow protection is selected by hazard level: air gap for high hazard, RPZ for high hazard, double check for low hazard.

  • Minimum drain slope is 1/4 inch per foot for small pipe and 1/8 inch per foot for large pipe where approved.

  • Water velocity limits: 8 fps cold, 5 fps hot, to control noise and erosion.

  • A plumbing system includes supply, fixtures, drainage, and venting; each component must be sized and installed as a system.

Quick reference

Plumbing Fixtures and Fixture Fittings

  • Water closet maximum flush: 1.6 gpf; high-efficiency: 1.28 gpf or less.

  • Urinal maximum flush: 1.0 gpf; waterless urinals use sealed trap cartridges.

  • Showerhead maximum flow: 2.5 gpm at 80 psi; kitchen faucet: 2.2 gpm; lavatory: 2.2 gpm.

  • Water closet clearance: 15 inches minimum from centerline to side wall; 30 inches minimum clear width.

  • Water closet compartment: 30 inches wide by 60 inches deep minimum, door swinging outward.

  • Air gap: at least 1 inch or twice the effective opening, never less than 1 inch above flood-level rim.

  • Floor drains require a 2-inch minimum trap seal; trap primers maintain seals in infrequently used drains.

Quick reference

Water Heaters and Related Equipment

  • T&P valve required on every storage water heater; setpoint not above 210°F or 150 psi.

  • T&P discharge pipe: full size, gravity-drained, terminates not more than 6 inches above floor, never trapped or reduced.

  • Thermal expansion tank required on closed systems with a check valve or backflow preventer.

  • Gas water heaters in garages: ignition sources elevated at least 18 inches unless FVIR listed.

  • Drain pan: at least 1.5 inches deep, drained by gravity or a listed pump.

  • Combustion air: 50 cubic feet per 1,000 Btu/hr from indoor volume, or two openings at 1 square inch per 4,000 Btu/hr.

  • Domestic hot water delivered to fixtures should not exceed 120°F at the point of use for scald control.

Quick reference

Water Supply and Distribution Systems

  • Minimum fixture pressure: 8 psi for flush tanks, 15 psi for flushometer valves; maximum 80 psi.

  • Pressure-reducing valve required above 80 psi; booster pump required below 8 psi.

  • Water service buried below frost depth; in New Hampshire typically 4 to 5 feet.

  • Developed length includes pipe run plus equivalent lengths for fittings; 90-degree elbows add 2 to 5 feet.

  • Water meter and main shutoff must be accessible; bypass allows service without interrupting supply.

  • Hot water recirculation or point-of-use heaters reduce dead legs and water waste.

  • Copper Type M is permitted above ground; Type L is used underground and for higher-pressure service.

Quick reference

Sanitary Drainage, Vents, and Storm Drainage

  • Drain slope: 1/4 inch per foot for 3-inch and smaller; 1/8 inch per foot for 4-inch and larger where approved.

  • Trap arm length: 1-1/2 inch pipe = 6 feet, 2 inch = 8 feet, 3 inch = 12 feet.

  • Vent stack must extend at least 6 inches above the roof; 12 inches where the roof is used for other purposes.

  • Vent terminal must be at least 10 feet from windows, doors, and air intakes.

  • Building drain connects to building sewer at least 2 feet outside the foundation.

  • Cleanouts required at the base of each stack, at the building drain, and every 100 feet in horizontal runs.

  • Storm drainage must be separate from sanitary drainage; backwater valves required where fixtures are below the upstream manhole elevation.

Quick reference

Fuel Gas Piping and Gas Appliances

  • Gas piping sized by longest length method or branch length method using total Btu/hr input and allowable pressure drop.

  • Natural gas: about 1,000 Btu per cubic foot; LP gas: about 2,500 Btu per cubic foot.

  • Gas shutoff valve within 6 feet of each appliance and in the same room; union or flanged connection allows removal.

  • Sediment trap required at each appliance unless designed without one; located downstream of the shutoff valve.

  • Low-pressure gas test: 1.5 times working pressure, not less than 3 psi, for 10 minutes.

  • Appliance connector: maximum 6 feet, must not pass through walls or floors, must not be concealed.

  • Gas leak testing uses air or inert gas, never oxygen; soap solution or electronic detector locates leaks.

Quick reference

New Hampshire Plumbing Code, Statutes, and Rules

  • New Hampshire adopts the International Plumbing Code with amendments in Administrative Rules Chapter Plc 300.

  • Plumbing work requires a license issued by the OPLC under RSA 329-A.

  • Journeyman plumber license requires documented experience (typically 4 years) and passage of the journeyman examination.

  • Licenses renew biennially; continuing education hours are required and must be documented.

  • A plumbing permit must be obtained from the local authority having jurisdiction before work begins.

  • Inspections must occur before concealment; work must be accessible for inspection.

  • Unlicensed plumbing work is subject to enforcement, fines, and permit revocation.

Quick reference

General Plumbing Knowledge

  • Plumbing includes supply, fixtures, drainage, and venting; each part must be sized as a coordinated system.

  • Water weighs 62.4 lb per cubic foot; 1 foot of head equals 0.433 psi.

  • Fixture units express probable load; 1 FU approximates 1 cubic foot per minute of drainage flow.

  • Trap seal depth must be 2 to 4 inches to prevent sewer gas entry.

  • Minimum drain slope is 1/4 inch per foot for small pipe; 1/8 inch per foot for large pipe where approved.

  • Backflow protection is selected by hazard level: air gap or RPZ for high hazard, double check for low hazard.

  • Water velocity limits: 8 fps cold, 5 fps hot, to control noise and erosion.

Quick reference

Plumbing Fixtures and Fixture Fittings

  • Water closet maximum flush: 1.6 gpf; high-efficiency models use 1.28 gpf or less.

  • Urinal maximum flush: 1.0 gpf; waterless urinals use a sealed trap cartridge.

  • Showerhead maximum flow: 2.5 gpm at 80 psi; kitchen and lavatory faucets: 2.2 gpm.

  • Water closet clearance: 15 inches minimum from centerline to side wall; 30 inches minimum clear width.

  • Water closet compartment: 30 inches wide by 60 inches deep minimum, door swinging outward.

  • Air gap: at least 1 inch or twice the effective opening, never less than 1 inch above the flood-level rim.

  • Floor drains require a 2-inch minimum trap seal; trap primers maintain seals in infrequently used drains.

Quick reference

Water Heaters and Related Equipment

  • T&P valve required on every storage water heater; setpoint not above 210°F or 150 psi.

  • T&P discharge pipe: full size, gravity-drained, terminates not more than 6 inches above the floor, never trapped or reduced.

  • Thermal expansion tank required on closed systems with a check valve or backflow preventer.

  • Gas water heaters in garages: ignition sources elevated at least 18 inches unless FVIR listed.

  • Drain pan: at least 1.5 inches deep, drained by gravity or a listed pump.

  • Combustion air: 50 cubic feet per 1,000 Btu/hr from indoor volume, or two openings at 1 square inch per 4,000 Btu/hr.

  • Domestic hot water delivered to fixtures should not exceed 120°F at the point of use.

Quick reference

Water Supply and Distribution Systems

  • Minimum fixture pressure: 8 psi for flush tanks, 15 psi for flushometer valves; maximum 80 psi.

  • Pressure-reducing valve required above 80 psi; booster pump required below 8 psi.

  • Water service buried below frost depth; in New Hampshire typically 4 to 5 feet.

  • Developed length includes pipe run plus equivalent lengths for fittings; 90-degree elbows add 2 to 5 feet.

  • Water meter and main shutoff must be accessible; bypass allows service without interrupting supply.

  • Hot water recirculation or point-of-use heaters reduce dead legs and water waste.

  • Copper Type M is permitted above ground; Type L is used underground and for higher-pressure service.

Quick reference

Sanitary Drainage, Vents, and Storm Drainage

  • Drain slope: 1/4 inch per foot for 3-inch and smaller; 1/8 inch per foot for 4-inch and larger where approved.

  • Trap arm length: 1-1/2 inch pipe = 6 feet, 2 inch = 8 feet, 3 inch = 12 feet.

  • Vent stack must extend at least 6 inches above the roof; 12 inches where the roof is used for other purposes.

  • Vent terminal must be at least 10 feet from windows, doors, and air intakes.

  • Building drain connects to building sewer at least 2 feet outside the foundation.

  • Cleanouts required at the base of each stack, at the building drain, and every 100 feet in horizontal runs.

  • Storm drainage must be separate from sanitary drainage; backwater valves required where fixtures are below the upstream manhole elevation.

Quick reference

Fuel Gas Piping and Gas Appliances

  • Gas piping sized by longest length method or branch length method using total Btu/hr input and allowable pressure drop.

  • Natural gas: about 1,000 Btu per cubic foot; LP gas: about 2,500 Btu per cubic foot.

  • Gas shutoff valve within 6 feet of each appliance and in the same room; union or flanged connection allows removal.

  • Sediment trap required at each appliance unless designed without one; located downstream of the shutoff valve.

  • Low-pressure gas test: 1.5 times working pressure, not less than 3 psi, for 10 minutes.

  • Appliance connector: maximum 6 feet, must not pass through walls or floors, must not be concealed.

  • Gas leak testing uses air or inert gas, never oxygen; soap solution or electronic detector locates leaks.

Quick reference

New Hampshire Plumbing Code, Statutes, and Rules

  • New Hampshire adopts the International Plumbing Code with amendments in Administrative Rules Chapter Plc 300.

  • Plumbing work requires a license issued by the OPLC under RSA 329-A.

  • Journeyman plumber license requires documented experience (typically 4 years) and passage of the journeyman examination.

  • Licenses renew biennially; continuing education hours are required and must be documented.

  • A plumbing permit must be obtained from the local authority having jurisdiction before work begins.

  • Inspections must occur before concealment; work must be accessible for inspection.

  • Unlicensed plumbing work is subject to enforcement, fines, and permit revocation.

Quick reference

General Plumbing Knowledge

  • Plumbing systems include water supply, fixtures, drainage, and venting, each sized and installed as a coordinated whole.

  • Water pressure conversion: 1 foot of head equals 0.433 psi; 1 psi equals 2.31 feet of head.

  • Fixture units express probable load; drainage sizing and supply sizing both use FU values as a common basis.

  • Trap seal depth must be 2 to 4 inches; the seal prevents sewer gas from entering the building.

  • Minimum drain slope is 1/4 inch per foot for 3-inch and smaller pipe; 1/8 inch per foot is permitted for 4-inch and larger where approved.

  • Backflow protection is chosen by hazard level: air gap or RPZ for high hazard, double check for low hazard.

  • Water velocity limits are 8 fps in cold water and 5 fps in hot water to control noise and erosion.

Quick reference

Plumbing Fixtures and Fixture Fittings

  • Water closet maximum flush: 1.6 gpf; high-efficiency models use 1.28 gpf or less.

  • Urinal maximum flush: 1.0 gpf; waterless urinals use a sealed trap cartridge.

  • Showerhead maximum flow: 2.5 gpm at 80 psi; kitchen and lavatory faucets: 2.2 gpm.

  • Water closet clearance: 15 inches minimum from centerline to side wall; 30 inches minimum clear width.

  • Water closet compartment: 30 inches wide by 60 inches deep minimum, door swinging outward.

  • Air gap: at least 1 inch or twice the effective opening, never less than 1 inch above the flood-level rim.

  • Floor drains require a 2-inch minimum trap seal; trap primers maintain seals in infrequently used drains.

Quick reference

Water Heaters and Related Equipment

  • T&P valve required on every storage water heater; setpoint not above 210°F or 150 psi.

  • T&P discharge pipe: full size, gravity-drained, terminates not more than 6 inches above the floor, never trapped or reduced.

  • Thermal expansion tank required on closed systems with a check valve or backflow preventer.

  • Gas water heaters in garages: ignition sources elevated at least 18 inches unless FVIR listed.

  • Drain pan: at least 1.5 inches deep, drained by gravity or a listed pump.

  • Combustion air: 50 cubic feet per 1,000 Btu/hr from indoor volume, or two openings at 1 square inch per 4,000 Btu/hr.

  • Domestic hot water delivered to fixtures should not exceed 120°F at the point of use.

Quick reference

Water Supply and Distribution Systems

  • Minimum fixture pressure: 8 psi for flush tanks, 15 psi for flushometer valves; maximum 80 psi.

  • Pressure-reducing valve required above 80 psi; booster pump required below 8 psi.

  • Water service buried below frost depth; in New Hampshire typically 4 to 5 feet.

  • Developed length includes pipe run plus equivalent lengths for fittings; 90-degree elbows add 2 to 5 feet.

  • Water meter and main shutoff must be accessible; bypass allows service without interrupting supply.

  • Hot water recirculation or point-of-use heaters reduce dead legs and water waste.

  • Copper Type M is permitted above ground; Type L is used underground and for higher-pressure service.

Quick reference

Sanitary Drainage, Vents, and Storm Drainage

  • Drain slope: 1/4 inch per foot for 3-inch and smaller; 1/8 inch per foot for 4-inch and larger where approved.

  • Trap arm length: 1-1/2 inch pipe = 6 feet, 2 inch = 8 feet, 3 inch = 12 feet.

  • Vent stack must extend at least 6 inches above the roof; 12 inches where the roof is used for other purposes.

  • Vent terminal must be at least 10 feet from windows, doors, and air intakes.

  • Building drain connects to building sewer at least 2 feet outside the foundation.

  • Cleanouts required at the base of each stack, at the building drain, and every 100 feet in horizontal runs.

  • Storm drainage must be separate from sanitary drainage; backwater valves required where fixtures are below the upstream manhole elevation.

Quick reference

Fuel Gas Piping and Gas Appliances

  • Gas piping sized by longest length method or branch length method using total Btu/hr input and allowable pressure drop.

  • Natural gas: about 1,000 Btu per cubic foot; LP gas: about 2,500 Btu per cubic foot.

  • Gas shutoff valve within 6 feet of each appliance and in the same room; union or flanged connection allows removal.

  • Sediment trap required at each appliance unless designed without one; located downstream of the shutoff valve.

  • Low-pressure gas test: 1.5 times working pressure, not less than 3 psi, for 10 minutes.

  • Appliance connector: maximum 6 feet, must not pass through walls or floors, must not be concealed.

  • Gas leak testing uses air or inert gas, never oxygen; soap solution or electronic detector locates leaks.

Quick reference

New Hampshire Plumbing Code, Statutes, and Rules

  • New Hampshire adopts the International Plumbing Code with amendments in Administrative Rules Chapter Plc 300.

  • Plumbing work requires a license issued by the OPLC under RSA 329-A.

  • Journeyman plumber license requires documented experience (typically 4 years) and passage of the journeyman examination.

  • Licenses renew biennially; continuing education hours are required and must be documented.

  • A plumbing permit must be obtained from the local authority having jurisdiction before work begins.

  • Inspections must occur before concealment; work must be accessible for inspection.

  • Unlicensed plumbing work is subject to enforcement, fines, and permit revocation.