National Home Inspector Examination cheat sheet

NHIE · Keep the key ideas within reach.

Quick reference

Structural Systems

  • Long horizontal cracks in a masonry or concrete foundation wall indicate lateral soil pressure or frost heave; narrow vertical cracks are more often shrinkage.

  • Notches in solid-lumber floor joists may not exceed 1/6 of the joist depth and are not allowed in the middle third of the span; bored holes may not exceed 1/3 of the depth.

  • Wood joists require at least 1-1/2 inches of bearing on wood or metal and 3 inches of bearing on masonry.

  • Crawlspace clearances: 18 inches beneath floor joists, 12 inches beneath girders, and 24 inches clear at the access opening.

  • Cutting, notching, or boring an engineered truss in the field requires written approval from a design professional.

  • Diagonal cracks radiating from the corners of door and window openings usually indicate differential foundation movement.

  • Wood framing in contact with concrete or soil must be pressure-treated or separated by an impermeable moisture barrier.

  • Stud notching is limited to 25 percent of the stud depth; bored holes may not exceed 40 percent of the depth.

Quick reference

Mechanical Systems

  • Furnace temperature rise is the supply-to-return air temperature difference and must fall within the data-plate range, commonly about 35-65 degrees F for gas units.

  • A properly operating central air conditioner produces roughly a 15-20 degree F difference between return and supply air.

  • The suction (large) refrigerant line must be insulated; the liquid (small) line is normally not insulated.

  • Condensate lines need a trap; the primary drain must not discharge into a crawlspace, and the secondary pan drain should terminate where overflow is visible.

  • Combustion air by indoor infiltration requires about 50 cubic feet of space per 1,000 BTU/h of appliance input.

  • Return air may not be drawn from a garage, bathroom, kitchen, or unconditioned space.

  • A cracked heat exchanger is a safety hazard because flue gases can enter the supply air stream.

  • Heat pumps move heat rather than generate it, so auxiliary resistance heat operating during defrost and cold weather is normal.

  • Dryer ducts must be smooth-walled, as short and straight as practical, and terminate outdoors with a backdraft damper.

Quick reference

Electrical Systems

  • Copper conductor ampacities: 14 AWG = 15 A, 12 AWG = 20 A, 10 AWG = 30 A.

  • GFCI protection is required in bathrooms, kitchens, garages, outdoors, unfinished basements, crawlspaces, and within 6 feet of a sink.

  • In a subpanel the neutral bus must be isolated from ground; the main bonding screw is used only at the service panel.

  • Receptacle spacing: no point on a wall may be more than 6 feet from a receptacle, and any wall space 2 feet or wider requires one.

  • Service-drop clearances: 10 feet above grade or walkways, 12 feet above a driveway, and 3 feet from an openable window.

  • A double-tapped breaker is improper unless the breaker is listed for two conductors.

  • Junction boxes must remain accessible; splices may not be buried in walls or ceilings.

  • AFCI protection is required on branch circuits serving bedrooms under modern code cycles.

  • Aluminum branch-circuit wiring is a fire concern and requires evaluated connections or replacement.

Quick reference

Plumbing Systems

  • A TPR valve relief pipe must terminate within 6 inches of the floor, be full size, unthreaded, untrapped, and have no valve in it.

  • Drain slope: 1/4 inch per foot for pipe 2 inches and smaller; 1/8 inch per foot for 3 inches and larger.

  • Residential supply pressure should be 40-80 psi; a pressure-reducing valve is needed above 80 psi.

  • Each fixture requires a trap, and the trap arm may not exceed the distance allowed to its vent.

  • A dielectric union or plastic fitting is required where copper meets galvanized steel to prevent galvanic corrosion.

  • A water heater needs a TPR valve and discharge pipe, and often an expansion tank on a closed system.

  • Vent terminals must extend above the roof and be located away from windows, doors, and air intakes.

  • A backwater valve on the sewer line protects the basement from reverse flow during surcharge.

Quick reference

Roofing

  • A chimney must extend at least 3 feet above the roof at the penetration and 2 feet above anything within 10 feet.

  • No more than two layers of asphalt shingles may remain on a roof; adding a third layer requires stripping the existing roofing.

  • Asphalt shingles require a minimum slope and special underlayment between 2:12 and 4:12; below 2:12 a membrane roof system is required.

  • Step flashing is installed at roof-to-sidewall intersections, with kick-out flashing at the bottom to divert water away from the wall.

  • Ice-dam protection membrane is required along eaves in cold climates and extends at least 24 inches inside the exterior wall line.

  • An open valley is lined with metal; a closed or woven valley conceals the flashing beneath the shingles.

  • Shingle fasteners must penetrate the sheathing at least 3/4 inch, with placement following the manufacturer's nailing pattern.

  • Attic ventilation is 1/150 of the attic floor area, or 1/300 where a vapor retarder is present.

Quick reference

Exterior and Site

  • Ground should slope at least 6 inches away from the foundation over the first 10 feet.

  • Siding should be at least 6 inches above finished grade and 1 inch above a roof surface.

  • Guardrail openings must not allow a 4-inch sphere to pass; residential deck guards are at least 36 inches high.

  • Handrails on stairs are 34-38 inches above the nosing.

  • Stair risers may not exceed 7-3/4 inches and treads must be at least 10 inches deep.

  • A deck ledger must be attached to the band joist with lag screws or through-bolts, flashed, and not attached through siding.

  • Downspouts should discharge away from the foundation; gutters generally need one downspout per 30-40 feet of run.

  • Decay is most likely at wood-to-ground contact, deck posts, sill plates, and masonry below grade.

Quick reference

Interior

  • Smoke alarms are required inside each bedroom, outside each sleeping area, and on every story.

  • The garage-to-house wall requires 1/2-inch gypsum board, and the door must be self-closing and solid-core or 20-minute rated.

  • Egress windows need at least 5.7 square feet of clear opening, 24 inches of height, 20 inches of width, and a sill no more than 44 inches above the floor.

  • Stairways must be at least 36 inches wide with 6 feet 8 inches of headroom.

  • Attic access openings must be at least 22 by 30 inches.

  • Safety glazing is required where glass is near a door, beside a stairway, or has a low sill height.

  • Cracks at drywall corners and above door openings usually relate to framing shrinkage or minor movement rather than structural failure.

  • Floor slope is measured and reported; a slope steeper than about 1 inch in 20 feet warrants further investigation.

Quick reference

Insulation and Ventilation

  • The vapor retarder goes on the warm side: interior in cold climates, exterior side in hot-humid climates.

  • Bath and kitchen exhaust fans must discharge outdoors, never into an attic or crawlspace.

  • Attic insulation must not block eave vents; baffles maintain a clear air channel from the soffit.

  • Recessed lights in an insulated ceiling must be IC-rated and sealed to limit air leakage.

  • A crawlspace should have a 6-mil vapor retarder over the soil, lapped and turned up the walls.

  • Typical insulation targets are R-38 to R-49 in attics and R-13 to R-21 in walls, depending on climate zone.

  • A blower-door test measures air leakage in air changes per hour at 50 pascals (ACH50).

  • Combustion appliances can backdraft when exhaust fans depressurize the house; test with the appliance and fans running.

Quick reference

Professional Practice

  • The standard inspection is visual and limited to readily accessible systems; it is not technically exhaustive or destructive.

  • Reports should state the observed condition, its implication, and a recommended action rather than only listing defects.

  • Inspectors should not state that a component 'meets code'; they report performance and safety concerns instead.

  • Performing repairs on a property inspected within the past 12 months is prohibited in many jurisdictions.

  • The inspection agreement should state scope, limitations, fee, and any dispute-resolution clause.

  • Photographs, model and serial numbers, and moisture readings support findings and reduce liability.

  • Inspectors must maintain client confidentiality and disclose any conflict of interest.

  • Any system not operated because of weather or safety concerns must be identified in the report as not inspected.