National Home Inspector Examination flashcards
NHIE · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Joist notch limit
- In solid-lumber floor joists, notches may not exceed one-sixth of the joist depth and are not permitted in the middle third of the span.
- Horizontal foundation crack
- Long horizontal cracks in a masonry or concrete foundation wall typically indicate lateral soil pressure or frost movement; vertical shrinkage cracks are usually narrower and less significant.
- Truss field modification
- Cutting, notching, or boring an engineered floor or roof truss in the field is not permitted without written approval from a design professional.
- Joist bearing minimum
- Wood joists need at least 1-1/2 inches of bearing on wood or metal supports and at least 3 inches of bearing on masonry.
- Furnace temperature rise
- The difference between return and supply air at a furnace; it must fall within the range on the manufacturer's data plate, commonly about 35 to 65 degrees Fahrenheit for gas units.
- Air conditioner delta T
- A central air conditioner in steady operation should deliver supply air about 15 to 20 degrees Fahrenheit cooler than the return air measured near the unit.
- Condensate drain requirements
- Primary condensate lines need a trap and must not drain into a crawlspace; a secondary pan drain should terminate where overflow can be seen.
- Combustion air rule
- Using indoor air infiltration, a gas appliance needs about 50 cubic feet of space per 1,000 BTU/h of input; otherwise dedicated outdoor combustion air is required.
- GFCI required locations
- Ground-fault protection is required in bathrooms, kitchens, garages, outdoors, unfinished basements, crawlspaces, and at receptacles within six feet of a sink.
- Copper wire ampacity
- 14 AWG copper conductors are rated 15 amps, 12 AWG are rated 20 amps, and 10 AWG are rated 30 amps for standard branch-circuit use.
- Subpanel neutral isolation
- In a subpanel the neutral bus must be isolated from the equipment ground, and the main bonding screw must be removed so ground and neutral stay separate.
- Receptacle spacing rule
- Along a dwelling's walls, no point may be more than six feet from a receptacle, and any wall space two feet or wider requires one.
- TPR discharge pipe rules
- A water heater relief valve pipe must terminate within six inches of the floor, be full size and unthreaded, and must not be trapped or fitted with a valve.
- Drain pipe slope
- Drain lines two inches and smaller slope one-quarter inch per foot; three-inch and larger lines slope one-eighth inch per foot.
- Water supply pressure
- Residential supply pressure should be between 40 and 80 psi; a pressure-reducing valve is needed when incoming pressure exceeds 80 psi.
- Dielectric union
- A fitting that separates dissimilar metals such as copper and galvanized steel to prevent galvanic corrosion at the threaded connection.
- Chimney 3-2-10 rule
- A chimney must extend at least three feet above the roof surface where it penetrates and at least two feet above anything within ten feet.
- Shingle layer limit
- No more than two layers of asphalt shingles may be installed or remain on a roof; a third layer requires stripping the old roofing.
- Step flashing
- L-shaped metal used at roof-to-sidewall intersections, installed in courses with the shingles; kick-out flashing at the bottom diverts water away from the wall.
- Ice dam membrane
- Self-adhering waterproof membrane required along eaves in cold climates, extending at least 24 inches inside the exterior wall line to prevent ice-dam leakage.
- Guardrail sphere rule
- Openings in a guardrail must be small enough that a four-inch sphere cannot pass through; guards on residential decks are at least 36 inches high.
- Handrail height
- Handrails along stairs are installed 34 to 38 inches above the stair nosing, and the handrail profile must be graspable.
- Siding clearance
- Exterior siding should be at least six inches above finished grade and one inch above roof surfaces to prevent moisture wicking and rot.
- Smoke alarm locations
- Smoke alarms are installed inside each bedroom, outside each sleeping area, and on every story of the dwelling, including basements.
- Garage separation wall
- The wall between an attached garage and living space needs at least half-inch gypsum board, and the door must be self-closing and solid or 20-minute rated.
- Egress window size
- An emergency egress window needs at least 5.7 square feet of clear opening, 24 inches of height, 20 inches of width, and a sill no higher than 44 inches.
- Exhaust fan discharge
- Bathroom and kitchen exhaust fans must terminate outdoors through smooth duct, never into an attic, crawlspace, or other interior space.
- Attic ventilation ratio
- Attic vent area should equal 1/150 of the attic floor area, or 1/300 when a vapor retarder is installed; roughly half the vents are intake at the eaves.
- Vapor retarder placement
- The vapor retarder faces the warm side of the assembly: on the interior in cold climates and toward the exterior in hot-humid climates.
- Inspection scope
- A standard home inspection is a visual, non-invasive examination of readily accessible systems and components on the day of the inspection; it is not technically exhaustive.
- Conflict of interest
- An inspector should not repair or perform work on a property they inspected, and many states prohibit such work for 12 months after the inspection.
- Reporting code compliance
- Inspectors describe observed conditions, their implications, and recommended actions; they do not certify that a component complies with building codes.