- NFPA 72
- National Fire Alarm and Signaling Code; sets design, installation, testing, and maintenance requirements for fire detection and notification systems.
- NEC Article 760
- Covers fire alarm system wiring, including power-limited and non-power-limited circuits, conductor types, separation, and installation requirements.
- FPLR cable
- Fire alarm cable rated for riser installation; suitable for vertical shafts where plenum rating is not required.
- FPLP cable
- Plenum-rated fire alarm cable; required in environmental air spaces and return air plenums unless enclosed in a raceway.
- AHJ
- Authority Having Jurisdiction; official who reviews, permits, inspects, and approves fire alarm installations and enforces the adopted code edition.
- NFPA 101
- Life Safety Code; addresses means of egress, occupancy protection, and when detection, alarm, and notification systems are required.
- Listed fire alarm equipment
- Equipment evaluated by a nationally recognized testing laboratory for fire alarm use and marked accordingly; required by NFPA 72.
- Smoke detector spacing
- On smooth ceilings, nominal spacing is 30 ft (9.1 m), with detectors within 15 ft of walls, partitions, or ceiling ends.
- Heat detector spacing
- Nominal spacing for standard heat detectors is 50 ft (15.2 m) on smooth ceilings, with detectors within 25 ft of walls or partitions.
- Manual pull station height
- Operating handle must be between 42 in and 48 in above finished floor and located within 5 ft of an exit doorway.
- Public mode audibility
- Alarm sound must be at least 15 dBA above average ambient or 5 dBA above maximum ambient, whichever is greater, with minimum 65 dBA.
- Sleeping area audibility
- Fire alarm sound must reach at least 75 dBA at the pillow or 15 dBA above ambient, whichever is greater.
- NAC voltage drop
- Use Vd = 2 x R x I x L for a two-wire loop; verify end-of-line voltage remains above the appliance minimum operating voltage.
- Battery standby capacity
- Secondary supply sized for 24 hours standby plus 5 minutes alarm; voice systems require 15 minutes alarm, with derating per manufacturer.
- Class B circuit
- Supervised circuit with an end-of-line resistor; a single open or ground fault may disable part of the circuit but the fault is annunciated.
- Class A circuit
- Supervised circuit with a redundant return path; remains operational after a single open fault and annunciates the trouble condition.
- Power-limited separation
- PLFA conductors must be separated from power conductors by at least 2 in or a listed barrier unless code permits otherwise.
- Dedicated AC circuit
- Fire alarm control unit requires a dedicated branch circuit, marked FIRE ALARM, with disconnect controlled by authorized personnel.
- Ground fault detection
- Fire alarm circuits must be monitored for unintentional ground connections; a ground fault should annunciate a trouble condition.
- Surge protection
- Listed transient protection installed on circuits leaving the building or exposed to lightning, per manufacturer and NFPA 72.
- Annual fire alarm test
- NFPA 72 requires at least annual functional testing of the complete fire alarm system, including initiating devices, notification appliances, and control functions.
- Smoke detector sensitivity
- Sensitivity checked within one year of installation and at least every alternate year thereafter, or per manufacturer's published instructions.
- Duct detector test
- Duct smoke detectors are tested annually using manufacturer method; airflow and sampling tube operation are verified and alarm signal confirmed.
- Impairment procedure
- Before testing or repair, notify owner, supervising station, and fire department as required; tag system and restore promptly after work.
- Record of inspection
- Written record documenting tests, results, deficiencies, and corrective actions; retained and made available to the authority having jurisdiction.
- Battery inspection
- Batteries inspected quarterly for corrosion, terminal tightness, and charging; load tested annually or per manufacturer instructions.
- Record of Completion
- NFPA 72 document signed by contractor and owner confirming system installation, tested functions, and compliance with approved plans.
- As-built drawings
- Updated drawings showing actual installed device locations, wiring routes, and panel details; provided to owner at project closeout.
- Submittal process
- Contractor submits shop drawings, product data, and calculations for approval before installation; approved submittals guide construction.
- RFI
- Request for Information; formal document asking designer to clarify plans or specifications before work proceeds.
- Change order
- Written authorization modifying contract scope, cost, or schedule after original agreement; required before extra work.
- Acceptance test
- Functional test of installed system witnessed by AHJ or owner's representative to verify code and design compliance before acceptance.