- Home improvement registration
- A credential issued by the New Jersey Division of Consumer Affairs that authorizes a contractor to perform home improvement work; the number must appear on contracts and advertising.
- Treble damages
- A remedy under the Consumer Fraud Act that multiplies the consumer's actual damages by three, plus attorney's fees and costs, for unlawful home improvement practices.
- Certificate of Formation
- The document filed with the New Jersey Division of Revenue and Enterprise Services to create a limited liability company or similar entity under state law.
- Workers' compensation requirement
- New Jersey law requires employers with one or more employees to carry workers' compensation insurance; sole proprietors and partners may elect coverage for themselves.
- Three-business-day cancellation
- The homeowner's right to cancel a home improvement contract until midnight of the third business day after signing, during which the contractor may not begin work.
- Down payment limit
- New Jersey home improvement regulations cap the deposit at one-third of the total contract price, with the balance payable as work progresses.
- Construction lien period
- A lien claimant must file a construction lien within 90 days after last furnishing labor or materials and must file suit to foreclose within one year.
- Written change order
- A signed amendment to the contract describing added or deleted work and its price; unsigned verbal changes are unenforceable and create Consumer Fraud Act exposure.
- Waste factor formula
- Order quantity equals net quantity multiplied by one plus the waste percentage; typical waste is 5-10% for framing lumber and 10% for roofing shingles.
- Board foot
- A unit of lumber volume equal to a piece one inch thick, twelve inches wide, and twelve inches long; computed as thickness times width times length divided by twelve.
- Cubic yards of concrete
- The volume of concrete in cubic yards equals length times width times depth in feet divided by 27, with 5-10% added for over-excavation and spillage.
- Critical path
- The longest sequence of dependent activities through a project network; it determines the shortest possible project duration and has zero float.
- Bid as offer
- A contractor's bid is a legally binding offer that the owner may accept; an invitation to bid is merely a request and is not itself an offer.
- Fall protection threshold
- OSHA requires fall protection in construction at six feet above a lower level, at ten feet for scaffolding, and at any height over dangerous equipment.
- Competent person
- An individual capable of identifying existing and predictable hazards and authorized to take prompt corrective measures to eliminate them, required for excavations and scaffolding.
- Excavation protective system
- Sloping, shoring, or shielding required for excavations five feet or deeper unless the excavation is entirely in stable rock.
- Hazard communication
- The OSHA requirement that employers maintain Safety Data Sheets, label chemical containers, and train employees on hazardous chemicals present at the worksite.
- Frost depth
- The depth to which soil freezes in winter; footings in New Jersey generally must bear below 30-36 inches depending on the county.
- Water-cement ratio
- The ratio of water to cementitious material in a concrete mix; a lower ratio increases strength and reduces permeability and shrinkage cracking.
- Slump test
- An ASTM C143 field test measuring concrete workability; typical residential foundation concrete has a slump of three to four inches.
- Concrete cylinder testing
- Standard cylinders are cured and tested at 7 and 28 days; 7-day strength typically reaches about 70-75% of the 28-day design strength.
- Joist notching limit
- Notches in the top or bottom of a floor joist cannot exceed one-sixth of the joist depth, and holes cannot exceed one-third of the depth.
- Joist bearing minimum
- Floor joists must bear at least 1.5 inches on wood or metal supports and at least 3 inches on masonry supports.
- Rafter length formula
- Rafter length equals the run divided by the cosine of the roof pitch angle; a 6/12 pitch corresponds to an angle of about 26.57 degrees.
- Shear wall
- A wall designed to resist lateral loads through sheathing and nailing, anchored to the foundation and continuous to the roof diaphragm.
- Ice dam membrane
- A self-adhering waterproofing membrane required along eaves, extending from the eave edge to at least 24 inches inside the exterior wall line.
- Step flashing
- L-shaped flashing installed at the sidewall-roof intersection in individual pieces woven with each shingle course to shed water away from the wall.
- Roof ventilation ratio
- Net free ventilating area should be at least 1/150 of the vented ceiling area, or 1/300 when a vapor retarder is installed and intake and exhaust are balanced.
- Window flashing sequence
- Sill pan first, then jamb flashing, then head flashing, so each layer sheds water outward over the layer below in shingle fashion.
- Electrical working clearance
- A clear space 30 inches wide, 36 inches deep, and 6.5 feet high in front of a panelboard; panels cannot be in clothes closets or bathrooms.
- GFCI protection locations
- Ground-fault circuit interrupter protection is required in bathrooms, kitchens, garages, outdoors, unfinished basements, and within six feet of sinks.
- Permit application action
- The construction official must act on a complete permit application within 20 business days; if not acted upon, the permit is deemed approved.