Quick reference

Source Water

  • A source water assessment identifies the susceptibility of each public water system intake or well to potential contaminant sources within its delineated area.

  • Groundwater under the direct influence of surface water (GUDI) is subject to surface water treatment rules because it can contain surface-water pathogens.

  • Specific capacity is pumping rate divided by drawdown, expressed as gallons per minute per foot of drawdown, and indicates well yield efficiency.

  • A well's safe yield is the maximum sustained pumping rate that does not cause excessive drawdown, interference, or water-quality deterioration.

  • Thermal stratification in a reservoir creates a warm upper layer and cold lower layer; turnover mixes the layers and can change raw-water turbidity, iron, manganese, and taste-and-odor compounds.

  • Wellhead protection areas are delineated zones around a well where contaminant sources can reach the well within a specified time of travel.

  • Surface water intakes are sited to avoid immediate pollution sources and to provide reliable withdrawal during low-flow conditions.

  • Raw-water quality parameters monitored at a surface intake include turbidity, pH, temperature, alkalinity, and bacterial indicators.

Quick reference

Water Quality and Public Health Protection

  • Primary maximum contaminant levels (MCLs) are enforceable health-based limits; secondary MCLs address aesthetic qualities such as taste, odor, color, and corrosivity.

  • The lead action level is 0.015 mg/L and the copper action level is 1.3 mg/L, evaluated at the 90th percentile of samples.

  • The nitrate MCL is 10 mg/L as nitrogen; the nitrite MCL is 1 mg/L as nitrogen.

  • The arsenic MCL for public water systems is 0.010 mg/L.

  • The Stage 2 Disinfectants/Disinfection Byproducts Rule uses locational running annual averages: TTHM 80 µg/L and HAA5 60 µg/L.

  • Filtered surface water systems using conventional treatment must meet turbidity of 0.3 NTU in at least 95% of monthly samples and never exceed 1 NTU.

  • The total coliform rule uses presence/absence results; E. coli-positive samples trigger repeat sampling and public notification requirements.

  • A detectable disinfectant residual in distribution helps limit microbial regrowth and indicates treatment integrity.

Quick reference

Treatment Processes and Process Control

  • CT is disinfectant concentration (mg/L) multiplied by contact time (minutes); CT requirements increase with pH for chlorine because hypochlorous acid dissociates to less effective hypochlorite.

  • Chlorine dose equals chlorine demand plus desired residual: dose = demand + residual.

  • Coagulation destabilizes particle charges; optimum coagulant dose and pH are determined by jar tests.

  • Flocculation provides gentle mixing to grow settleable floc after rapid mix; sedimentation removes floc before filtration.

  • Granular media filters remove particles; backwashing uses upward flow with expansion to remove captured solids, followed by filter-to-waste or ripening.

  • Lime-soda softening removes calcium and magnesium hardness by precipitation, producing sludge that must be handled.

  • Aeration strips volatile organic compounds and hydrogen sulfide and can oxidize iron and manganese to filterable forms.

  • Granular activated carbon adsorbs organic compounds; powdered activated carbon is dosed for temporary taste-and-odor or spill response.

  • Membrane processes are classified by pore size: microfiltration and ultrafiltration remove particles and microbes; reverse osmosis removes dissolved ions.

Quick reference

Distribution and Collection System Operation

  • Distribution systems are operated to maintain positive pressure; a minimum of 20 psi is required during main breaks and fire-flow conditions to prevent contamination.

  • Water age increases in oversized mains, dead ends, and low-demand areas; flushing and storage turnover reduce stagnation.

  • An air gap is the highest-hazard backflow protection because it provides a physical separation between potable and nonpotable water.

  • A reduced-pressure-zone backflow preventer uses two check valves and a relief valve to protect against both backpressure and backsiphonage.

  • After a main repair, the main is disinfected, flushed, and sampled for bacteriological quality before being returned to service.

  • Gravity sanitary sewers are designed for self-cleansing velocity, typically about 2 ft/s at full or design flow, to prevent solids deposition.

  • Infiltration is groundwater entering a sewer through defects; inflow is stormwater entering through direct connections such as roof drains or catch basins.

  • A sanitary sewer overflow is a release of untreated sewage from the collection system and must be reported and corrected under NJDEP requirements.

Quick reference

Equipment, Maintenance, Pumps and Safety

  • Centrifugal pump affinity laws: flow varies directly with impeller speed, head with the square of speed, and brake horsepower with the cube of speed.

  • Pump brake horsepower = (flow in gpm × total head in ft) / (3960 × pump efficiency).

  • Cavitation occurs when local pressure drops below vapor pressure, forming vapor bubbles that collapse and damage impellers; adequate NPSH prevents it.

  • The operating point of a pump is the intersection of the pump curve and the system-head curve.

  • A confined space entry requires testing for oxygen, flammable gas, and toxic gas; entry proceeds only if oxygen is at least 19.5%.

  • Lockout/tagout isolates hazardous energy before maintenance and requires verification that the equipment cannot be started.

  • Portable ladders are set at a 4:1 slope: one foot of base distance for every four feet of working height.

  • Excessive pump vibration, bearing temperature, or packing leakage indicates mechanical wear or misalignment and is tracked through preventive maintenance.

Quick reference

Monitoring, Sampling, Laboratory Analysis and Reporting

  • Chlorine residual is measured at the time of sampling because chlorine is unstable; the DPD colorimetric method is commonly used.

  • Bacteriological drinking water samples are collected in sterile bottles containing sodium thiosulfate to neutralize chlorine and are held no more than 30 hours before analysis.

  • Turbidity is reported in nephelometric turbidity units (NTU) and is measured with a calibrated nephelometer.

  • A chain-of-custody form documents sample possession from collection through laboratory analysis and supports legal defensibility.

  • Quality control samples include method blanks, duplicates, matrix spikes, and known standards to verify accuracy and precision.

  • Sample preservation and holding times are method-specific; pH, temperature, and residual chlorine are generally measured in the field.

  • Laboratory results outside permit limits trigger confirmation, resampling, and reporting according to the system's monitoring schedule.

Quick reference

Regulations, Records, Security and Administration

  • The New Jersey Safe Drinking Water Act is administered by NJDEP's Bureau of Safe Drinking Water, which oversees public water system compliance.

  • Public water systems must be operated by licensed operators; operator licenses are classified by system type and grade and require continuing education.

  • The Consumer Confidence Report summarizes source water, detected contaminants, and health effects and is distributed annually to customers.

  • Public notification is tiered by risk: Tier 1 is immediate for acute health risks, Tier 2 within 30 days, and Tier 3 in the annual report.

  • A sanitary survey is an on-site inspection of a public water system's source, treatment, distribution, operation, and records.

  • Wastewater dischargers covered by an NJPDES permit submit discharge monitoring reports (DMRs) that document compliance with permit limits.

  • Records such as monitoring results, operating logs, and maintenance records are retained for specified periods and made available to the regulatory agency.

  • Security measures include controlling access to treatment chemicals, intakes, and control systems and reporting suspicious activity to authorities.