NJ Water/Wastewater Operator flashcards
NJ Water/Wastewater Operator · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Watershed protection area
- Land area draining to a surface water intake where contaminant sources can affect raw-water quality; delineating it supports source water protection planning and monitoring.
- Groundwater under direct influence
- Groundwater that is hydraulically connected to surface water and may contain surface-water pathogens; it is regulated like surface water and requires appropriate treatment barriers.
- Specific capacity
- Well yield divided by drawdown, usually expressed in gallons per minute per foot; a higher value indicates a more efficient well and aquifer connection.
- Reservoir turnover
- Seasonal mixing of a stratified reservoir when surface and bottom waters reach similar density; it can resuspend sediments and release iron, manganese, and taste-and-odor compounds.
- Wellhead protection area
- A delineated zone around a public well where potential contaminant sources can reach the well within a specified time of travel; used for land-use and source protection.
- Primary MCL
- An enforceable maximum contaminant level set to protect public health from a contaminant in drinking water; violations require treatment, reporting, and public notification.
- Secondary MCL
- A non-enforceable drinking water standard for aesthetic qualities such as taste, odor, color, corrosivity, or foaming; it helps systems manage consumer acceptance rather than acute health risk.
- Lead action level
- The 90th-percentile lead concentration of 0.015 mg/L in tap samples; exceeding it triggers corrosion control, public education, and lead service line replacement requirements.
- Total coliform MCL
- A drinking water rule limit based on the presence of total coliform bacteria in routine and repeat samples; systems that exceed it must assess the distribution system and notify the public.
- Disinfection byproduct LRAA
- Locational running annual average used for TTHM and HAA5 compliance; the limits are 80 µg/L for TTHM and 60 µg/L for HAA5 at each monitoring location.
- CT
- Disinfectant concentration in mg/L multiplied by contact time in minutes; regulatory CT tables specify required values based on disinfectant, temperature, pH, and pathogen.
- Coagulation
- A treatment step that destabilizes suspended particle charges so particles can collide and agglomerate; optimum coagulant dose and pH are established by jar testing.
- Flocculation
- Gentle mixing after rapid mix that encourages small destabilized particles to collide and grow into larger floc that can be removed by sedimentation and filtration.
- Filter backwash
- An upward-flow washing step that expands granular filter media and removes captured solids; it is followed by media ripening or filter-to-waste before normal service.
- Lime-soda softening
- A precipitation process that removes calcium and magnesium hardness by adding lime and sometimes soda ash; it produces sludge and raises pH, requiring stabilization.
- Cross-connection
- Any actual or potential link between a potable water system and a nonpotable source; it creates a pathway for contamination by backpressure or backsiphonage.
- Air gap
- A physical separation between a potable water outlet and the highest possible level of a nonpotable receiving vessel; it is the highest-level backflow protection.
- Minimum distribution pressure
- The lowest pressure that must be maintained in a water main to prevent contamination; 20 psi is the common regulatory minimum during main breaks and fire flow.
- Infiltration and inflow
- Infiltration is groundwater entering sewers through defects, while inflow is stormwater entering through direct connections; both add clear water that reduces treatment capacity.
- Sanitary sewer overflow
- A release of untreated sewage from a collection system before reaching the treatment plant; it must be reported, contained, and corrected under state requirements.
- Cavitation
- Formation and collapse of vapor bubbles in a pump when local pressure falls below vapor pressure; it causes noise, vibration, and impeller damage and is prevented by adequate NPSH.
- Affinity laws
- Pump relationships showing flow changes directly with speed, head with the square of speed, and power with the cube of speed for a constant impeller diameter.
- Confined space entry
- Entry into a space with limited access and poor ventilation; testing must show oxygen at least 19.5%, no flammable gas, and acceptable toxic gas before entry.
- Lockout tagout
- An energy-control procedure that isolates power sources with locks and tags before maintenance; it prevents accidental startup and release of stored energy.
- DPD method
- A colorimetric test for chlorine residual in which DPD reagent reacts with chlorine to produce a color measured by a photometer or comparator.
- Bacteriological holding time
- Drinking water bacteriological samples must be analyzed within 30 hours of collection; sterile bottles contain sodium thiosulfate to neutralize chlorine.
- Chain of custody
- A written record tracking sample possession, time, and location from collection through laboratory analysis; it supports data integrity and regulatory defensibility.
- Turbidity NTU
- Nephelometric turbidity units measure light scattering by suspended particles; turbidity is a key indicator of filtration performance and microbial risk.
- Consumer Confidence Report
- An annual report that public water systems provide to customers describing source water, detected contaminants, compliance, and health effects; it is due by July 1.
- Sanitary survey
- An on-site inspection by the primacy agency of a public water system's source, treatment, distribution, operation, and records to identify sanitary defects and compliance issues.
- NJPDES DMR
- A discharge monitoring report submitted by an NJPDES-permitted wastewater facility; it records monitoring results and demonstrates compliance with permit effluent limits.
- Tier 1 public notice
- Immediate public notification required for acute health risks such as E. coli or nitrate exceedances; the system must notify customers within 24 hours and consult the primacy agency.