New Mexico Low Voltage Practice key terms
New Mexico Low Voltage Practice · Get comfortable with the vocabulary.
- Ohm's Law
- Related: Voltage Drop, Power Formula
The relationship stating that voltage equals current multiplied by resistance (E = I × R); knowing any two values lets you calculate the third in a DC circuit.
- Power Formula
- Related: Ohm's Law, Power Factor
The equation P = E × I for DC circuits, giving wattage from voltage and current; in AC circuits it must be adjusted by the power factor for true power.
- Power Factor
- Related: Power Formula, Volt-Ampere
The ratio of true power to apparent power in an AC circuit, expressed from 0 to 1; low values mean more current is drawn for the same useful work.
- Voltage Drop
- Related: Ohm's Law, Circular Mil
The loss of voltage along conductors caused by their resistance, reducing voltage at the load; long low-voltage runs make this a critical design concern.
- Circular Mil
- Related: Voltage Drop, Ampacity
A unit of conductor cross-sectional area based on the square of the diameter in thousandths of an inch; used in voltage-drop and ampacity calculations.
- Ampacity
- Related: Circular Mil, Derating
The maximum current a conductor can carry continuously under stated conditions without exceeding its temperature rating; determined from tables and corrected for ambient temperature and conduit fill.
- Derating
- Related: Ampacity, Conduit Fill
Reducing a conductor's allowable ampacity to account for conditions such as high ambient temperature or many current-carrying conductors bundled in one raceway.
- Series Circuit
- Related: Parallel Circuit, Ohm's Law
A circuit with a single current path where the same current flows through every component and the total resistance is the sum of individual resistances.
- Parallel Circuit
- Related: Series Circuit, Ohm's Law
A circuit with multiple current paths across the same voltage, where total current is the sum of branch currents and total resistance is less than any single branch.
- Class 2 Circuit
- Related: Class 3 Circuit, Power-Limited Circuit
A circuit supplied by a listed power source limited in voltage and energy so it presents low fire and shock hazard, allowing less restrictive wiring methods for control and signal loads.
- Class 3 Circuit
- Related: Class 2 Circuit, Power-Limited Circuit
A circuit with voltage and power limits higher than Class 2 but still controlled, permitting lighter wiring methods than line-voltage branch circuits while requiring some separation from power conductors.
- Power-Limited Circuit
- Related: Class 2 Circuit, NPLFA Circuit
A circuit whose source is listed and limits available current and voltage, typically used for fire alarm, security, and communication equipment so standard wiring methods may be relaxed.
- NPLFA Circuit
- Related: PLFA Circuit, Power-Limited Circuit
Non-power-limited fire alarm circuit; a fire alarm circuit not limited in power, requiring line-voltage wiring methods and separation from power-limited circuits.
- PLFA Circuit
- Related: NPLFA Circuit, Class 2 Circuit
Power-limited fire alarm circuit; a fire alarm circuit supplied by a listed limited-power source, allowing reduced wiring requirements under the fire alarm article.
- Volt-Ampere
- Related: Power Factor, Power Formula
The unit of apparent power in an AC circuit, equal to RMS voltage multiplied by RMS current without regard to phase angle between them.
- Grounding Electrode System
- Related: Equipment Grounding Conductor, Bonding
The set of electrodes and bonding jumpers that connects an electrical system to earth, establishing a reference potential and providing a path for lightning and fault currents.
- Equipment Grounding Conductor
- Related: Grounding Electrode System, Bonding
The conductor that connects the metal enclosure of equipment to the grounding system, providing a low-impedance path for fault current so overcurrent devices open.
- Bonding
- Related: Equipment Grounding Conductor, Grounding Electrode System
The permanent joining of metal parts to form an electrically conductive path that ensures electrical continuity and the capacity to conduct fault current safely.
- Raceway
- Related: Conduit Fill, EMT
An enclosed channel of metal or nonmetallic material designed to hold and protect conductors, such as conduit, tubing, or wireway.
- EMT
- Related: Raceway, Conduit Fill
Electrical metallic tubing; a thin-wall steel or aluminum raceway joined with couplings and connectors, widely used indoors for exposed and concealed low-voltage feeder runs.
- Conduit Fill
- Related: Raceway, Derating
The percentage of a raceway's internal cross section occupied by conductors; limits prevent overheating and make pulling conductors practical.
- Plenum
- Related: Riser, Cable Jacket Rating
A space used for air handling in a building, such as above a suspended ceiling; cable installed there must be listed for plenum use with low smoke and flame characteristics.
- Riser
- Related: Plenum, Cable Jacket Rating
A vertical shaft or run between floors; cables installed in it generally must carry a riser rating unless enclosed in a raceway or otherwise protected.
- Cable Jacket Rating
- Related: Plenum, Riser
The listing designation (such as CMP, CMR, CM, or CMX) indicating where a communications cable may be installed based on its flame and smoke performance.
- Box Fill
- Related: Raceway, Derating
The required internal volume of an outlet, device, or junction box based on the number and size of conductors, devices, and fittings it contains.
- Overcurrent Protective Device
- Related: Ampacity, Equipment Grounding Conductor
A breaker or fuse that opens a circuit when current exceeds its rating, protecting conductors and equipment from overheating and fault damage.
- Working Clearance
- Related: Lockout/Tagout, Arc Flash
The required clear space in front of electrical equipment that allows a person to work safely and escape a hazard without obstruction.
- Lockout/Tagout
- Related: Working Clearance, Arc Flash
A procedure for de-energizing equipment, applying a lock and tag, and verifying absence of voltage before work begins so energy cannot be unexpectedly restored.
- Arc Flash
- Related: Lockout/Tagout, PPE
A dangerous release of energy caused by an electrical fault through air, producing intense heat, light, and pressure; requires appropriate personal protective equipment and safe work practices.
- PPE
- Related: Arc Flash, Lockout/Tagout
Personal protective equipment such as insulated gloves, arc-rated clothing, and eye protection worn to reduce injury from shock, arc flash, and physical hazards.
- Multimeter
- Related: Continuity Tester, Toner and Probe
A test instrument that measures voltage, resistance, and often current; selecting the correct function and range before contact with a circuit is essential for safety and accuracy.
- Continuity Tester
- Related: Multimeter, Toner and Probe
A device that confirms an unbroken conductive path by signaling when resistance is very low; used on de-energized conductors to verify connections and identify opens.
- Toner and Probe
- Related: Multimeter, Continuity Tester
A pair of tools used to trace and identify a specific cable among many by injecting a signal on one end and locating it with a receiver at the other.
- Permit
- Related: Inspection, Contract
An official authorization from the local building or electrical authority to perform specified work, typically required before installation and followed by inspections.
- Contract
- Related: Change Order, Lien
A legally binding agreement defining scope, price, schedule, and responsibilities between a contractor and client; changes should be documented in writing.
- Change Order
- Related: Contract, Lien
A written amendment to a contract that adjusts scope, price, or schedule; without one, extra work may go uncompensated.
- Lien
- Related: Contract, Change Order
A legal claim against property securing payment for labor or materials supplied; contractors and suppliers may file one when unpaid.
- Inspection
- Related: Permit, AHJ
A review of installed work by the authority having jurisdiction to confirm compliance with adopted codes before the work is covered or energized.
- AHJ
- Related: Inspection, Permit
Authority having jurisdiction; the organization or individual responsible for approving equipment, installations, and enforcing the adopted code in a given area.
- Addressable System
- Related: Conventional System, Initiating Device
A fire alarm architecture in which each device has a unique address, letting the panel identify the exact device in alarm or trouble rather than only a zone.
- Conventional System
- Related: Addressable System, Initiating Device
A fire alarm arrangement where devices share a zone circuit, so the panel reports the zone rather than the individual device that activated.
- Initiating Device
- Related: Notification Appliance, Addressable System
A component such as a smoke detector, pull station, or waterflow switch that signals the fire alarm control unit when a fire condition is detected.
- Notification Appliance
- Related: Initiating Device, Addressable System
A device such as a horn, strobe, or speaker that alerts occupants of a fire alarm condition using audible or visible signals.
- Balun
- Related: Structured Cabling, Toner and Probe
A transformer device that converts between balanced and unbalanced signals, commonly used to carry video or data over twisted-pair cable.
- Structured Cabling
- Related: Balun, Cable Jacket Rating
A standardized layout of data cabling using defined subsystems, connectors, and distances so voice, data, and video services can be reliably installed and changed.