NM Water/Wastewater Operator study materials
NM Water/Wastewater Operator study resources

NM Water/Wastewater Operator flashcards

NM Water/Wastewater Operator · Build recall with a focused review session.

32 cards. Read the term and the definition here. The deck at the top of this page is optional.

CT value
CT is disinfectant residual concentration in mg/L multiplied by contact time in minutes; required CT rises with pH and falls as water temperature rises.
Jar test purpose
A jar test simulates coagulation, flocculation, and settling at several chemical doses so the operator can choose the most effective coagulant dose and pH.
Filter loading rate
Filter loading rate equals flow in gallons per minute divided by filter surface area in square feet; rapid sand filters typically run 2 to 4 gpm per square foot.
Filtered water turbidity limit
Combined filter effluent must stay at or below 0.3 NTU in at least 95 percent of monthly samples and must never exceed 1 NTU.
Detention time formula
Detention time in hours equals basin volume in gallons divided by flow in gallons per minute, then divided again by 60 minutes per hour.
Chlorine dose calculation
Pounds per day of chlorine equals the milligrams per liter dose times flow in million gallons per day times 8.34 pounds per gallon of water.
Fluoride drinking water standards
The primary drinking water standard for fluoride is 4.0 mg/L, while 2.0 mg/L is the secondary standard that protects against dental fluorosis.
Langelier saturation index
The Langelier index compares measured pH to the pH at which water is calcium carbonate saturated; negative values indicate corrosive water, positive values indicate scale-forming water.
Pressure and head
One foot of water column produces 0.433 psi, and one psi equals 2.31 feet of head, so a 100-foot elevation difference is about 43.3 psi.
Flow in a pipe
Flow in gallons per minute equals 2.448 times the pipe inside diameter in inches squared times the velocity in feet per second.
Minimum chlorine residual
A detectable free chlorine residual of at least 0.2 mg/L must be maintained throughout the distribution system; the maximum residual disinfectant level is 4.0 mg/L.
Air gap backflow protection
An air gap is a physical separation of at least twice the supply pipe diameter above the flood rim, giving the highest protection against cross-connection backflow.
New main disinfection
New water mains are chlorinated with a 50 mg/L chlorine solution held 24 hours, then flushed and sampled for coliform bacteria before being placed in service.
Water hammer cause
Water hammer is a pressure surge caused by rapid velocity change when a valve closes quickly or a pump stops suddenly; surge tanks and slow-closing valves reduce it.
Distribution storage purpose
Distribution storage provides equalizing capacity for peak demands, fire flow reserves, and emergency supply; equalizing volume is commonly 15 to 25 percent of maximum day demand.
Cavitation in pumps
Cavitation is vapor bubble formation and collapse at a pump impeller caused by low net positive suction head; it produces noise, vibration, and impeller damage.
F/M ratio
Food-to-microorganism ratio equals pounds of BOD5 applied per day divided by pounds of MLVSS in the aeration tank; typical values are 0.05 to 0.4 per day.
Sludge volume index
SVI equals settled sludge volume in mL/L after 30 minutes times 1000 divided by MLSS in mg/L; values of 80 to 150 indicate good settling.
Mean cell residence time
MCRT equals pounds of solids in the aeration tank divided by pounds of solids leaving the system daily in waste sludge and effluent.
Nitrification oxygen and alkalinity
Oxidizing one pound of ammonia nitrogen to nitrate consumes about 7.14 pounds of alkalinity as calcium carbonate and about 4.6 pounds of oxygen.
Return activated sludge
Return activated sludge is settled biomass pumped from the clarifier back to the aeration tank to maintain the desired mixed liquor suspended solids concentration.
BOD5 test meaning
Biochemical oxygen demand measures oxygen consumed by microorganisms decomposing organic matter in five days at 20 degrees Celsius, indicating wastewater strength.
Facultative lagoon
A facultative lagoon has an aerobic upper layer and an anaerobic bottom layer; algae supply oxygen by photosynthesis while bacteria stabilize organic matter throughout the depth.
Chlorine contact basin
The disinfection contact basin must provide enough detention time, commonly 20 to 30 minutes at peak flow, for the chlorine dose to inactivate pathogens.
Minimum sewer velocity
Gravity sanitary sewers are designed for a minimum self-cleaning velocity of 2 feet per second to prevent deposition of grit and solids.
Manning equation
Manning's equation is V equals 1.486 divided by n, times hydraulic radius to the two-thirds power, times slope to the one-half power in English units.
Infiltration and inflow
Infiltration is groundwater entering sewers through defects, while inflow is storm water entering through direct connections such as roof drains and catch basins.
Confined space entry oxygen
Confined space entry requires oxygen between 19.5 and 23.5 percent, hydrogen sulfide below 10 ppm, and combustible gas below 10 percent of the lower explosive limit.
Drop manhole purpose
A drop manhole is used where a sewer entering a manhole is more than about 24 inches above the outgoing invert, preventing turbulence and hydrogen sulfide release.
Smoke testing sewers
Smoke testing forces nontoxic smoke into a sewer to reveal illegal storm connections, broken pipes, and manhole defects that admit inflow and infiltration.
Lift station wet well
A lift station wet well stores wastewater so pumps cycle between start and stop levels; usable volume is set from pump capacity and allowable starts per hour.
Grease trap function
A grease trap slows flow so fats, oils, and grease float and are retained while wastewater passes on to the sewer, reducing blockages and treatment upsets.