NRPP RMI study materials
NRPP RMI study resources

NRPP RMI cheat sheet

NRPP RMI · Keep the key ideas within reach.

Quick reference

Radon Measurement Professional: Core Measurement Knowledge

  • Radon-222 is a noble gas produced by alpha decay of Ra-226 (half-life 1600 y); its own half-life is 3.82 days, and it decays through short-lived progeny (Po-218, Pb-214, Bi-214, Po-214) that emit the alpha particles relevant to dose.

  • Units: 1 pCi/L = 37 Bq/m3; working level (WL) = 100 pCi/L of radon in equilibrium with progeny (2.08 x 10^-5 J/m3 of potential alpha energy); 1 WLM = 170 WL-hours per month (approx. 200 pCi/L for one working month at home occupancy).

  • EPA action level for homes is 4 pCi/L; the EPA recommended action level for schools and large buildings is also 4 pCi/L, with follow-up testing required at 4 pCi/L or above and consideration of mitigation between 2 and 4 pCi/L.

  • Equilibrium ratio (ER) = actual progeny concentration divided by the equilibrium-adjusted radon concentration; typical indoor ER is 0.3-0.7. Working level ratio (WLR) relates measured WL to radon concentration: WL = (Rn pCi/L) x ER / 100.

  • Short-term tests run 2-90 days; the EPA protocol for real-estate and general screening uses a minimum 48-hour closed-building test (12 hours closed before the test begins, doors and windows closed, normal HVAC operation with no exhaust fans).

  • Long-term tests run more than 90 days (typically 3-12 months) and are preferred because they average seasonal variation; radon in the lowest lived-in level is normally highest in winter and lowest in summer.

  • Detection methods: activated charcoal adsorption (short-term, 2-7 days, sensitive to temperature and humidity), alpha-track/electret ion chambers (long-term), continuous radon monitors (CRM, hourly data, require calibration and anti-tamper features), and charcoal liquid scintillation.

  • Placement rules: 20 inches (50 cm) above the floor, at least 12 inches (30 cm) from exterior walls, at least 4 inches (10 cm) from other objects, at least 3 feet (91 cm) from windows, doors, or vents, and not in bathrooms, kitchens, laundry rooms, closets, or crawl spaces.

  • Duplicate/blank QA: at least 10% duplicates and 5% blanks, or one of each per 10 measurements if fewer than 10 devices are deployed; results must be reported to the client in the units and time frame specified by the client's protocol.

Quick reference

Radon Measurement Professional: QA, Calibration, and Reporting

  • A measurement professional must be certified by an EPA-recognized proficiency program (NRPP or NRSB) and maintain device-specific certification; each device type listed on the certification is separately covered and requires its own QA records.

  • Spike tests verify accuracy against a known radon concentration; at least 3 spiked devices per 100 deployed devices (or 3 per year for low-volume testers) must be analyzed, and results should be within +/- 25% of the known value (or +/- 10% for CRM calibration checks).

  • Duplicate measurements assess precision: at least 10% of deployed devices or 50 per year, whichever is smaller, with relative percent difference (RPD) between duplicates typically within 25% for charcoal and 20% for alpha-track.

  • Blank (background) devices are undeployed devices analyzed to detect contamination or detector background; at least 5% of deployed devices or 25 per year, whichever is smaller, and blank results should be below the device's lower limit of detection.

  • CRM calibration: continuous monitors must be calibrated at least annually with a known radon source (or cross-calibrated against a calibrated CRM), and calibration factors documented; a daily check source or internal self-test is required each day of use.

  • Lower limit of detection (LLD) for charcoal devices is typically 0.5-1.0 pCi/L; results below the LLD should be reported as less than that value, not as zero. Alpha-track LLDs are typically 0.3-1.0 pCi/L depending on exposure length.

  • Reporting requirements: report results in pCi/L (or Bq/m3), identify the test method and device, state test start and end dates, closed-building conditions, and the EPA action level of 4 pCi/L; include a recommendation for follow-up testing when results are 4 pCi/L or higher.

  • Chain-of-custody: devices must be logged with deployment and retrieval dates/times, location, and device serial numbers; samples must reach the lab within the device's hold time (typically 7 days for charcoal, longer for alpha-track).

  • Tamper indicators: a CRM must record hourly data and show no evidence of tampering or unusual environmental conditions (e.g., doors/windows open, high humidity); a test with evidence of interference should be invalidated and repeated.

Quick reference

Radon Measurement Professional: Test Protocols and Mitigation Decision Rules

  • Real-estate test protocol: the test must be conducted in the lowest livable level, with the building closed for 12 hours before the test starts, and the test must last at least 48 hours; the seller and buyer must be informed that the test is being conducted and must not interfere with closed-building conditions.

  • Post-mitigation testing: after a mitigation system is installed, a follow-up test must be conducted at least 24 hours after system start-up and within 30 days of installation, using a minimum 48-hour test; results should be below 4 pCi/L (and ideally below 2 pCi/L).

  • If a short-term test result is 4 pCi/L or higher, a follow-up test is required: either a second short-term test (2-90 days) or a long-term test (more than 90 days); the average of the two short-term tests or the long-term result determines whether mitigation is recommended.

  • For real-estate transactions, if the first short-term test is 4 pCi/L or higher, a second short-term test should be conducted immediately, and the average of the two tests is used to decide whether mitigation is needed.

  • Mitigation decision: if the average of two short-term tests or a long-term test is 4 pCi/L or higher, mitigation is recommended; if the result is between 2 and 4 pCi/L, consider mitigation and retest periodically.

  • When a radon mitigation system is installed, the professional should verify that the system is functioning (fan operating, pressure field extension, and post-mitigation test) and provide the client with a completed system label and operation/maintenance instructions.

  • For schools and large buildings, testing should be conducted in all frequently occupied rooms in contact with the ground, and in rooms above unoccupied spaces; if any room tests at 4 pCi/L or higher, follow-up testing and mitigation are recommended.

  • Closed-building conditions must be documented: windows and doors closed (except for normal entry/exit), no whole-house or window fans operating, and normal HVAC operation; deviations should be noted in the report and may invalidate the test.

Quick reference

Radon Measurement Professional: Health Effects, Physics, and Building Science

  • Health risk: radon is the second leading cause of lung cancer after smoking and the leading cause among non-smokers; the risk increases with exposure concentration and duration, and the EPA estimates that about 21,000 lung cancer deaths per year in the U.S. are radon-related.

  • The alpha particles from radon progeny deposit energy in the bronchial epithelium; the dose is driven by progeny concentration (WL), not radon gas alone, which is why the equilibrium ratio matters for interpreting results.

  • Radon entry: soil gas enters through cracks in the foundation, sump pits, floor drains, and gaps around pipes; the driving forces are the stack effect (pressure difference due to temperature), wind, and mechanical exhaust.

  • Building pressure: exhaust fans, dryers, and fireplaces can depressurize a house and increase radon entry; a mitigation system uses a sub-slab depressurization fan to reverse the pressure gradient and vent soil gas above the roof.

  • Seasonal and daily variation: radon concentrations typically peak in winter (stack effect strongest) and vary with weather (low pressure systems, rain, and snow cover can increase indoor radon); a single short-term test may not represent annual average.

  • The EPA action level of 4 pCi/L is not a health-based threshold; it is a practical action level, and the EPA recommends considering mitigation at 2-4 pCi/L because there is no known safe level of radon exposure.

  • Radon decay products: Po-218 and Po-214 are the alpha emitters; Pb-214 and Bi-214 are beta/gamma emitters; the progeny reach equilibrium with radon in about 3-4 hours in closed conditions.

  • Measurement physics: charcoal devices adsorb radon by diffusion and are analyzed by gamma spectroscopy or liquid scintillation; alpha-track detectors use a plastic film that records alpha tracks, which are counted after chemical etching.

Quick reference

Radon Measurement Professional: Regulations, Certification, and Ethics

  • The EPA's Indoor Radon Abatement Act (1988) and the Radon Measurement Proficiency (RMP) program established the framework for proficiency testing; the current proficiency programs are NRPP (National Radon Proficiency Program) and NRSB (National Radon Safety Board).

  • Certification requires passing an exam, maintaining continuing education (typically 8-16 hours per 2-year cycle depending on the program), and complying with the program's quality assurance and ethics requirements.

  • The Radon Measurement Professional must follow the EPA's Protocols for Radon and Radon Decay Product Measurements in Homes (EPA 402-R-92-003) and the EPA's Residential Measurement Protocol; these define closed-building conditions, placement, and QA requirements.

  • Disclosure: in real-estate transactions, the measurement professional must disclose any business relationship with a mitigation contractor and must not condition the test result on the sale of mitigation services.

  • Recordkeeping: retain test records, QA results, and calibration records for at least 3 years (or as required by the certification program), and make them available to the certification body upon request.

  • Liability: the measurement professional is responsible for the accuracy of the test and must not alter results; reporting a result below the LLD as zero or failing to report a result above the action level is a violation of professional standards.

  • State regulations: some states (e.g., New Jersey, Pennsylvania, Florida) have their own radon certification and reporting requirements that may be stricter than the EPA protocols; the professional must comply with the state in which the test is conducted.

  • Conflict of interest: a measurement professional should not perform mitigation on the same property within a specified period (often 1 year) unless disclosed, and should not use test results to pressure a client into purchasing mitigation services.

Quick reference

Radon Measurement Professional: Device Handling and Field Procedures

  • Device deployment: place the device in the lowest livable level, at least 20 inches above the floor, 12 inches from exterior walls, and 4 inches from other objects; avoid areas with high humidity, drafts, or direct sunlight.

  • Charcoal device handling: open the device only at the test location, record the exact start time, and reseal immediately at the end of the exposure period; exposure time must match the device's specified range (typically 2-7 days).

  • CRM deployment: place the monitor in the lowest livable level, verify it is functioning and calibrated, and record hourly data; the monitor should be placed on a stable surface and not moved during the test.

  • Chain of custody: record device serial numbers, deployment and retrieval dates/times, location, and the name of the person who deployed and retrieved the device; ship samples to the lab within the device's hold time.

  • Interference: if the occupant reports opening windows or using exhaust fans during the test, the test may be invalid; document the interference and consider retesting.

  • Quality assurance: deploy duplicates and blanks as required, and ensure that at least 10% of devices are duplicates and 5% are blanks (or the minimum specified by the certification program).

  • Post-test: report results to the client within the timeframe specified by the contract (typically 5-10 business days), and include the test method, dates, and the EPA action level.

  • Safety: radon test devices pose minimal risk to the professional; however, charcoal devices should be handled to avoid contamination, and CRM calibration sources should be handled according to the manufacturer's instructions.

Quick reference

Radon Measurement Professional: Data Interpretation and Client Communication

  • Result interpretation: a result below 2 pCi/L is low; 2-4 pCi/L is a consideration zone; 4 pCi/L or higher requires follow-up testing and mitigation is recommended if confirmed.

  • Averaging: when two short-term tests are conducted, the average is used to decide whether mitigation is needed; if the two results differ by more than a factor of 2, consider a third test or a long-term test.

  • Uncertainty: report results with the device's uncertainty (typically +/- 10-25%); a result of 4.0 pCi/L with a 25% uncertainty could be as low as 3.0 pCi/L, which is why follow-up testing is recommended.

  • Client communication: explain that radon is a health risk, that the action level is 4 pCi/L, and that mitigation is recommended at or above that level; avoid alarming language and provide the EPA's consumer guidance.

  • Follow-up testing: if the initial test is 4 pCi/L or higher, recommend a second short-term test or a long-term test; if the average of two short-term tests is 4 pCi/L or higher, recommend mitigation.

  • Mitigation options: sub-slab depressurization, drain tile depressurization, block wall depressurization, and sub-membrane depressurization for crawl spaces; the professional should refer the client to a certified mitigation contractor.

  • Documentation: provide the client with a written report that includes the test method, dates, results, QA information, and the recommendation; retain a copy for at least 3 years.

  • Ethics: do not guarantee a specific result, do not pressure the client to mitigate, and do not perform mitigation on the same property without disclosure and compliance with state regulations.

Quick reference

Radon Measurement Professional: Measurement Methods and Instrumentation

  • Activated charcoal adsorption: passive device, 2-7 day exposure, analyzed by gamma spectroscopy or liquid scintillation; sensitive to temperature and humidity, so devices must be placed in conditioned spaces.

  • Alpha-track detector (ATD): passive device, 1-12 month exposure, plastic film etched and counted; not sensitive to humidity, suitable for long-term tests; LLD typically 0.3-1.0 pCi/L.

  • Electret ion chamber (EIC): passive device, short- or long-term, uses a charged electret whose voltage drop is proportional to radon exposure; requires voltage measurement before and after exposure.

  • Continuous radon monitor (CRM): active device, records hourly radon concentrations, provides short-term results and tamper detection; requires annual calibration and daily function checks.

  • Charcoal liquid scintillation (LS): charcoal device analyzed by liquid scintillation counting; provides short-term results and is sensitive to humidity.

  • Radon progeny measurement: uses a filter to collect progeny and a detector to measure alpha activity; working level (WL) is calculated from the progeny concentration, and the equilibrium ratio is used to estimate radon concentration.

  • Instrument selection: choose the method based on test duration, required sensitivity, and the client's needs; short-term tests use charcoal or CRM, long-term tests use ATD or EIC.

  • Calibration: all devices must be calibrated according to the manufacturer's instructions and the certification program's requirements; CRM calibration is typically annual, and passive devices are calibrated by the manufacturer.

Quick reference

Radon Measurement Professional: Mitigation and Post-Mitigation Verification

  • Sub-slab depressurization (SSD): the most common mitigation method; a fan draws soil gas from beneath the slab and vents it above the roof; the system should create a negative pressure field beneath the slab.

  • Drain tile depressurization: used when a drain tile system is present; the fan is connected to the drain tile and vents soil gas above the roof.

  • Block wall depressurization: used for hollow block foundation walls; the fan draws air from the block wall cavities and vents it above the roof.

  • Sub-membrane depressurization: used for crawl spaces; a membrane is placed over the soil and the fan draws soil gas from beneath the membrane.

  • Post-mitigation testing: conduct a test at least 24 hours after system start-up and within 30 days of installation; the result should be below 4 pCi/L and ideally below 2 pCi/L.

  • System verification: check that the fan is operating, the pressure field is established, and the system label is affixed; provide the client with operation and maintenance instructions.

  • Maintenance: the system should be inspected annually, and the fan should be checked for operation; the client should be advised to retest every 2 years.

  • Communication: explain the mitigation system to the client, including the fan location, vent location, and the need for annual maintenance; provide a copy of the post-mitigation test report.

Quick reference

Radon Measurement Professional: Professional Standards and Continuing Education

  • Certification: maintain certification through NRPP or NRSB, complete continuing education (typically 8-16 hours per 2-year cycle), and comply with the program's code of ethics.

  • Continuing education: courses should cover radon measurement, mitigation, health effects, and regulations; the professional should keep records of completed courses.

  • Code of ethics: provide accurate results, avoid conflicts of interest, maintain confidentiality, and comply with all applicable laws and regulations.

  • Professional development: stay current with EPA protocols, state regulations, and new measurement technologies; participate in proficiency testing programs.

  • Recordkeeping: retain test records, QA results, and calibration records for at least 3 years; make them available to the certification body upon request.

  • Client communication: provide clear, accurate information about radon risks and mitigation options; avoid guaranteeing specific results or pressuring clients.

  • Liability: the professional is responsible for the accuracy of the test and must not alter results; reporting a result below the LLD as zero or failing to report a result above the action level is a violation.

  • State regulations: comply with the state in which the test is conducted; some states have stricter requirements than the EPA protocols.

Quick reference

Radon Measurement Professional: Real Estate and Relocation Testing

  • Real-estate test: conduct the test in the lowest livable level, with the building closed for 12 hours before the test starts, and the test must last at least 48 hours; the test should be conducted by a certified professional.

  • Disclosure: the measurement professional must disclose any business relationship with a mitigation contractor and must not condition the test result on the sale of mitigation services.

  • Follow-up: if the first short-term test is 4 pCi/L or higher, a second short-term test should be conducted immediately, and the average of the two tests is used to decide whether mitigation is needed.

  • Timing: the test should be conducted before the sale is finalized, and the results should be provided to the buyer and seller; the test should not be conducted during a real-estate transaction if the building is not in closed-building conditions.

  • Relocation testing: for relocation companies, the test should follow the same protocol as a real-estate test, and the results should be provided to the relocation company and the client.

  • Documentation: provide a written report that includes the test method, dates, results, QA information, and the recommendation; retain a copy for at least 3 years.

  • Ethics: do not guarantee a specific result, do not pressure the client to mitigate, and do not perform mitigation on the same property without disclosure and compliance with state regulations.

  • Communication: explain the results to the client in clear language, including the action level and the recommendation for follow-up testing or mitigation.

Quick reference

Radon Measurement Professional: Quality Assurance and Quality Control

  • QA program: a written QA plan that includes device calibration, duplicate and blank measurements, spike tests, and recordkeeping.

  • Duplicates: at least 10% of deployed devices or 50 per year, whichever is smaller; RPD between duplicates typically within 25% for charcoal and 20% for alpha-track.

  • Blanks: at least 5% of deployed devices or 25 per year, whichever is smaller; blank results should be below the device's LLD.

  • Spikes: at least 3 spiked devices per 100 deployed devices (or 3 per year for low-volume testers); results should be within +/- 25% of the known value (or +/- 10% for CRM calibration checks).

  • Calibration: all devices must be calibrated according to the manufacturer's instructions and the certification program's requirements; CRM calibration is typically annual.

  • Recordkeeping: retain QA records, calibration records, and test records for at least 3 years; make them available to the certification body upon request.

  • Corrective action: if QA results are outside acceptable limits, investigate the cause, correct the problem, and document the corrective action.

  • Proficiency testing: participate in the certification program's proficiency testing program and maintain a passing score.

Quick reference

Radon Measurement Professional: Health Effects and Risk Communication

  • Radon is the second leading cause of lung cancer after smoking and the leading cause among non-smokers; the EPA estimates about 21,000 lung cancer deaths per year in the U.S. are radon-related.

  • Risk increases with exposure concentration and duration; there is no known safe level of radon exposure, which is why the EPA recommends considering mitigation at 2-4 pCi/L.

  • The alpha particles from radon progeny deposit energy in the bronchial epithelium; the dose is driven by progeny concentration (WL), not radon gas alone.

  • Smoking and radon exposure act synergistically; smokers exposed to radon have a much higher lung cancer risk than non-smokers exposed to the same radon level.

  • Risk communication: explain the risk in clear, non-alarming language, provide the EPA's consumer guidance, and avoid guaranteeing specific results.

  • Action level: the EPA action level of 4 pCi/L is not a health-based threshold; it is a practical action level, and the EPA recommends considering mitigation at 2-4 pCi/L.

  • Follow-up testing: if the initial test is 4 pCi/L or higher, recommend a second short-term test or a long-term test; if the average of two short-term tests is 4 pCi/L or higher, recommend mitigation.

  • Mitigation: refer the client to a certified mitigation contractor and explain the mitigation options (SSD, drain tile, block wall, sub-membrane).

Quick reference

Radon Measurement Professional: Building Science and Radon Entry

  • Radon entry: soil gas enters through cracks in the foundation, sump pits, floor drains, and gaps around pipes; the driving forces are the stack effect, wind, and mechanical exhaust.

  • Stack effect: warm indoor air rises and escapes through the upper floors, creating a negative pressure in the lower levels that draws soil gas in; the effect is strongest in winter.

  • Depressurization: exhaust fans, dryers, and fireplaces can depressurize a house and increase radon entry; a mitigation system uses a sub-slab depressurization fan to reverse the pressure gradient.

  • Building pressure: the pressure difference between the soil and the indoor air drives radon entry; a mitigation system should create a negative pressure field beneath the slab.

  • Foundation types: basements, crawl spaces, and slab-on-grade foundations all can have radon entry; the mitigation method depends on the foundation type.

  • HVAC: normal HVAC operation should be maintained during a test, but exhaust fans and whole-house fans should not be operated during the closed-building period.

  • Weather: low pressure systems, rain, and snow cover can increase indoor radon; a single short-term test may not represent the annual average.

  • Mitigation: sub-slab depressurization, drain tile depressurization, block wall depressurization, and sub-membrane depressurization for crawl spaces.

Quick reference

Radon Measurement Professional: Measurement Uncertainty and Statistics

  • Uncertainty: report results with the device's uncertainty (typically +/- 10-25%); a result of 4.0 pCi/L with a 25% uncertainty could be as low as 3.0 pCi/L.

  • Averaging: when two short-term tests are conducted, the average is used to decide whether mitigation is needed; if the two results differ by more than a factor of 2, consider a third test or a long-term test.

  • LLD: the lower limit of detection is the lowest concentration that can be reliably detected; results below the LLD should be reported as less than that value, not as zero.

  • Precision: duplicates assess precision; RPD between duplicates typically within 25% for charcoal and 20% for alpha-track.

  • Accuracy: spikes assess accuracy; results should be within +/- 25% of the known value (or +/- 10% for CRM calibration checks).

  • Statistical significance: a single short-term test may not be statistically representative of the annual average; long-term tests are preferred for decision-making.

  • Reporting: report results in pCi/L (or Bq/m3) and include the uncertainty and the LLD.

  • Data interpretation: a result below 2 pCi/L is low; 2-4 pCi/L is a consideration zone; 4 pCi/L or higher requires follow-up testing.

Quick reference

Radon Measurement Professional: Regulations and Standards

  • EPA protocols: the EPA's Protocols for Radon and Radon Decay Product Measurements in Homes (EPA 402-R-92-003) and the Residential Measurement Protocol define closed-building conditions, placement, and QA requirements.

  • Certification: NRPP and NRSB are the current proficiency programs; certification requires passing an exam, maintaining continuing education, and complying with the program's QA and ethics requirements.

  • State regulations: some states (e.g., New Jersey, Pennsylvania, Florida) have their own radon certification and reporting requirements that may be stricter than the EPA protocols.

  • Disclosure: in real-estate transactions, the measurement professional must disclose any business relationship with a mitigation contractor and must not condition the test result on the sale of mitigation services.

  • Recordkeeping: retain test records, QA results, and calibration records for at least 3 years (or as required by the certification program).

  • Liability: the measurement professional is responsible for the accuracy of the test and must not alter results.

  • Conflict of interest: a measurement professional should not perform mitigation on the same property within a specified period (often 1 year) unless disclosed.

  • Continuing education: complete 8-16 hours per 2-year cycle depending on the program; courses should cover radon measurement, mitigation, health effects, and regulations.

Quick reference

Radon Measurement Professional: Field Procedures and Device Handling

  • Placement: 20 inches above the floor, 12 inches from exterior walls, 4 inches from other objects, 3 feet from windows, doors, or vents; avoid bathrooms, kitchens, laundry rooms, closets, and crawl spaces.

  • Charcoal: open the device only at the test location, record the exact start time, and reseal immediately at the end of the exposure period; exposure time must match the device's specified range.

  • CRM: place the monitor in the lowest livable level, verify it is functioning and calibrated, and record hourly data; the monitor should be placed on a stable surface and not moved during the test.

  • Chain of custody: record device serial numbers, deployment and retrieval dates/times, location, and the name of the person who deployed and retrieved the device.

  • Interference: if the occupant reports opening windows or using exhaust fans during the test, the test may be invalid; document the interference and consider retesting.

  • QA: deploy duplicates and blanks as required; at least 10% duplicates and 5% blanks (or the minimum specified by the certification program).

  • Reporting: report results to the client within the timeframe specified by the contract (typically 5-10 business days).

  • Safety: handle charcoal devices to avoid contamination; handle CRM calibration sources according to the manufacturer's instructions.

Quick reference

Radon Measurement Professional: Client Communication and Ethics

  • Client communication: explain that radon is a health risk, that the action level is 4 pCi/L, and that mitigation is recommended at or above that level; avoid alarming language.

  • Follow-up: if the initial test is 4 pCi/L or higher, recommend a second short-term test or a long-term test; if the average of two short-term tests is 4 pCi/L or higher, recommend mitigation.

  • Mitigation: refer the client to a certified mitigation contractor and explain the mitigation options (SSD, drain tile, block wall, sub-membrane).

  • Documentation: provide a written report that includes the test method, dates, results, QA information, and the recommendation; retain a copy for at least 3 years.

  • Ethics: do not guarantee a specific result, do not pressure the client to mitigate, and do not perform mitigation on the same property without disclosure.

  • Confidentiality: maintain the confidentiality of client information and test results.

  • Conflict of interest: disclose any business relationship with a mitigation contractor and do not condition the test result on the sale of mitigation services.

  • Professional development: stay current with EPA protocols, state regulations, and new measurement technologies.

Quick reference

Radon Measurement Professional: Measurement Methods and Instrumentation

  • Activated charcoal: passive, 2-7 day exposure, analyzed by gamma spectroscopy or liquid scintillation; sensitive to temperature and humidity.

  • Alpha-track: passive, 1-12 month exposure, plastic film etched and counted; not sensitive to humidity, suitable for long-term tests.

  • Electret ion chamber: passive, short- or long-term, uses a charged electret whose voltage drop is proportional to radon exposure.

  • CRM: active, records hourly radon concentrations, provides short-term results and tamper detection; requires annual calibration and daily function checks.

  • Charcoal liquid scintillation: charcoal device analyzed by liquid scintillation counting; provides short-term results and is sensitive to humidity.

  • Radon progeny measurement: uses a filter to collect progeny and a detector to measure alpha activity; WL is calculated from the progeny concentration.

  • Instrument selection: choose the method based on test duration, required sensitivity, and the client's needs.

  • Calibration: all devices must be calibrated according to the manufacturer's instructions and the certification program's requirements.

Quick reference

Radon Measurement Professional: Mitigation and Post-Mitigation Verification

  • Sub-slab depressurization: the most common mitigation method; a fan draws soil gas from beneath the slab and vents it above the roof.

  • Drain tile depressurization: used when a drain tile system is present; the fan is connected to the drain tile and vents soil gas above the roof.

  • Block wall depressurization: used for hollow block foundation walls; the fan draws air from the block wall cavities and vents it above the roof.

  • Sub-membrane depressurization: used for crawl spaces; a membrane is placed over the soil and the fan draws soil gas from beneath the membrane.

  • Post-mitigation testing: conduct a test at least 24 hours after system start-up and within 30 days of installation; the result should be below 4 pCi/L.

  • System verification: check that the fan is operating, the pressure field is established, and the system label is affixed.

  • Maintenance: the system should be inspected annually, and the fan should be checked for operation; the client should be advised to retest every 2 years.

  • Communication: explain the mitigation system to the client, including the fan location, vent location, and the need for annual maintenance.

Quick reference

Radon Measurement Professional: Professional Standards and Continuing Education

  • Certification: maintain certification through NRPP or NRSB, complete continuing education (typically 8-16 hours per 2-year cycle), and comply with the program's code of ethics.

  • Continuing education: courses should cover radon measurement, mitigation, health effects, and regulations; keep records of completed courses.

  • Code of ethics: provide accurate results, avoid conflicts of interest, maintain confidentiality, and comply with all applicable laws and regulations.

  • Professional development: stay current with EPA protocols, state regulations, and new measurement technologies; participate in proficiency testing programs.

  • Recordkeeping: retain test records, QA results, and calibration records for at least 3 years.

  • Client communication: provide clear, accurate information about radon risks and mitigation options.

  • Liability: the professional is responsible for the accuracy of the test and must not alter results.

  • State regulations: comply with the state in which the test is conducted; some states have stricter requirements than the EPA protocols.

Quick reference

Radon Measurement Professional: Real Estate and Relocation Testing

  • Real-estate test: conduct the test in the lowest livable level, with the building closed for 12 hours before the test starts, and the test must last at least 48 hours.

  • Disclosure: the measurement professional must disclose any business relationship with a mitigation contractor and must not condition the test result on the sale of mitigation services.

  • Follow-up: if the first short-term test is 4 pCi/L or higher, a second short-term test should be conducted immediately, and the average of the two tests is used.

  • Timing: the test should be conducted before the sale is finalized, and the results should be provided to the buyer and seller.

  • Relocation testing: for relocation companies, the test should follow the same protocol as a real-estate test.

  • Documentation: provide a written report that includes the test method, dates, results, QA information, and the recommendation.

  • Ethics: do not guarantee a specific result, do not pressure the client to mitigate, and do not perform mitigation on the same property without disclosure.

  • Communication: explain the results to the client in clear language, including the action level and the recommendation.

Quick reference

Radon Measurement Professional: Quality Assurance and Quality Control

  • QA program: a written QA plan that includes device calibration, duplicate and blank measurements, spike tests, and recordkeeping.

  • Duplicates: at least 10% of deployed devices or 50 per year, whichever is smaller; RPD between duplicates typically within 25% for charcoal and 20% for alpha-track.

  • Blanks: at least 5% of deployed devices or 25 per year, whichever is smaller; blank results should be below the device's LLD.

  • Spikes: at least 3 spiked devices per 100 deployed devices (or 3 per year for low-volume testers); results should be within +/- 25% of the known value.

  • Calibration: all devices must be calibrated according to the manufacturer's instructions and the certification program's requirements.

  • Recordkeeping: retain QA records, calibration records, and test records for at least 3 years.

  • Corrective action: if QA results are outside acceptable limits, investigate the cause, correct the problem, and document the corrective action.

  • Proficiency testing: participate in the certification program's proficiency testing program and maintain a passing score.

Quick reference

Radon Measurement Professional: Health Effects and Risk Communication

  • Radon is the second leading cause of lung cancer after smoking and the leading cause among non-smokers; the EPA estimates about 21,000 lung cancer deaths per year in the U.S. are radon-related.

  • Risk increases with exposure concentration and duration; there is no known safe level of radon exposure.

  • The alpha particles from radon progeny deposit energy in the bronchial epithelium; the dose is driven by progeny concentration (WL), not radon gas alone.

  • Smoking and radon exposure act synergistically; smokers exposed to radon have a much higher lung cancer risk than non-smokers.

  • Risk communication: explain the risk in clear, non-alarming language, provide the EPA's consumer guidance, and avoid guaranteeing specific results.

  • Action level: the EPA action level of 4 pCi/L is not a health-based threshold; it is a practical action level.

  • Follow-up testing: if the initial test is 4 pCi/L or higher, recommend a second short-term test or a long-term test.

  • Mitigation: refer the client to a certified mitigation contractor and explain the mitigation options.

Quick reference

Radon Measurement Professional: Building Science and Radon Entry

  • Radon entry: soil gas enters through cracks in the foundation, sump pits, floor drains, and gaps around pipes; the driving forces are the stack effect, wind, and mechanical exhaust.

  • Stack effect: warm indoor air rises and escapes through the upper floors, creating a negative pressure in the lower levels that draws soil gas in.

  • Depressurization: exhaust fans, dryers, and fireplaces can depressurize a house and increase radon entry.

  • Building pressure: the pressure difference between the soil and the indoor air drives radon entry; a mitigation system should create a negative pressure field beneath the slab.

  • Foundation types: basements, crawl spaces, and slab-on-grade foundations all can have radon entry.

  • HVAC: normal HVAC operation should be maintained during a test, but exhaust fans and whole-house fans should not be operated during the closed-building period.

  • Weather: low pressure systems, rain, and snow cover can increase indoor radon.

  • Mitigation: sub-slab depressurization, drain tile depressurization, block wall depressurization, and sub-membrane depressurization for crawl spaces.

Quick reference

Radon Measurement Professional: Measurement Uncertainty and Statistics

  • Uncertainty: report results with the device's uncertainty (typically +/- 10-25%).

  • Averaging: when two short-term tests are conducted, the average is used to decide whether mitigation is needed.

  • LLD: the lower limit of detection is the lowest concentration that can be reliably detected; results below the LLD should be reported as less than that value.

  • Precision: duplicates assess precision; RPD between duplicates typically within 25% for charcoal and 20% for alpha-track.

  • Accuracy: spikes assess accuracy; results should be within +/- 25% of the known value.

  • Statistical significance: a single short-term test may not be statistically representative of the annual average.

  • Reporting: report results in pCi/L (or Bq/m3) and include the uncertainty and the LLD.

  • Data interpretation: a result below 2 pCi/L is low; 2-4 pCi/L is a consideration zone; 4 pCi/L or higher requires follow-up testing.

Quick reference

Radon Measurement Professional: Regulations and Standards

  • EPA protocols: the EPA's Protocols for Radon and Radon Decay Product Measurements in Homes (EPA 402-R-92-003) and the Residential Measurement Protocol define closed-building conditions, placement, and QA requirements.

  • Certification: NRPP and NRSB are the current proficiency programs; certification requires passing an exam, maintaining continuing education, and complying with the program's QA and ethics requirements.

  • State regulations: some states have their own radon certification and reporting requirements that may be stricter than the EPA protocols.

  • Disclosure: in real-estate transactions, the measurement professional must disclose any business relationship with a mitigation contractor.

  • Recordkeeping: retain test records, QA results, and calibration records for at least 3 years.

  • Liability: the measurement professional is responsible for the accuracy of the test and must not alter results.

  • Conflict of interest: a measurement professional should not perform mitigation on the same property within a specified period (often 1 year) unless disclosed.

  • Continuing education: complete 8-16 hours per 2-year cycle depending on the program.

Quick reference

Radon Measurement Professional: Field Procedures and Device Handling

  • Placement: 20 inches above the floor, 12 inches from exterior walls, 4 inches from other objects, 3 feet from windows, doors, or vents.

  • Charcoal: open the device only at the test location, record the exact start time, and reseal immediately at the end of the exposure period.

  • CRM: place the monitor in the lowest livable level, verify it is functioning and calibrated, and record hourly data.

  • Chain of custody: record device serial numbers, deployment and retrieval dates/times, location, and the name of the person who deployed and retrieved the device.

  • Interference: if the occupant reports opening windows or using exhaust fans during the test, the test may be invalid.

  • QA: deploy duplicates and blanks as required; at least 10% duplicates and 5% blanks.

  • Reporting: report results to the client within the timeframe specified by the contract.

  • Safety: handle charcoal devices to avoid contamination; handle CRM calibration sources according to the manufacturer's instructions.

Quick reference

Radon Measurement Professional: Client Communication and Ethics

  • Client communication: explain that radon is a health risk, that the action level is 4 pCi/L, and that mitigation is recommended at or above that level.

  • Follow-up: if the initial test is 4 pCi/L or higher, recommend a second short-term test or a long-term test.

  • Mitigation: refer the client to a certified mitigation contractor and explain the mitigation options.

  • Documentation: provide a written report that includes the test method, dates, results, QA information, and the recommendation.

  • Ethics: do not guarantee a specific result, do not pressure the client to mitigate, and do not perform mitigation on the same property without disclosure.

  • Confidentiality: maintain the confidentiality of client information and test results.

  • Conflict of interest: disclose any business relationship with a mitigation contractor.

  • Professional development: stay current with EPA protocols, state regulations, and new measurement technologies.

Quick reference

Radon Measurement Professional: Measurement Methods and Instrumentation

  • Activated charcoal: passive, 2-7 day exposure, analyzed by gamma spectroscopy or liquid scintillation.

  • Alpha-track: passive, 1-12 month exposure, plastic film etched and counted.

  • Electret ion chamber: passive, short- or long-term, uses a charged electret whose voltage drop is proportional to radon exposure.

  • CRM: active, records hourly radon concentrations, provides short-term results and tamper detection.

  • Charcoal liquid scintillation: charcoal device analyzed by liquid scintillation counting.

  • Radon progeny measurement: uses a filter to collect progeny and a detector to measure alpha activity.

  • Instrument selection: choose the method based on test duration, required sensitivity, and the client's needs.

  • Calibration: all devices must be calibrated according to the manufacturer's instructions and the certification program's requirements.

Quick reference

Radon Measurement Professional: Mitigation and Post-Mitigation Verification

  • Sub-slab depressurization: the most common mitigation method; a fan draws soil gas from beneath the slab and vents it above the roof.

  • Drain tile depressurization: used when a drain tile system is present; the fan is connected to the drain tile and vents soil gas above the roof.

  • Block wall depressurization: used for hollow block foundation walls; the fan draws air from the block wall cavities and vents it above the roof.

  • Sub-membrane depressurization: used for crawl spaces; a membrane is placed over the soil and the fan draws soil gas from beneath the membrane.

  • Post-mitigation testing: conduct a test at least 24 hours after system start-up and within 30 days of installation.

  • System verification: check that the fan is operating, the pressure field is established, and the system label is affixed.

  • Maintenance: the system should be inspected annually, and the fan should be checked for operation.

  • Communication: explain the mitigation system to the client, including the fan location, vent location, and the need for annual maintenance.

Quick reference

Radon Measurement Professional: Professional Standards and Continuing Education

  • Certification: maintain certification through NRPP or NRSB, complete continuing education (typically 8-16 hours per 2-year cycle), and comply with the program's code of ethics.

  • Continuing education: courses should cover radon measurement, mitigation, health effects, and regulations.

  • Code of ethics: provide accurate results, avoid conflicts of interest, maintain confidentiality, and comply with all applicable laws and regulations.

  • Professional development: stay current with EPA protocols, state regulations, and new measurement technologies.

  • Recordkeeping: retain test records, QA results, and calibration records for at least 3 years.

  • Client communication: provide clear, accurate information about radon risks and mitigation options.

  • Liability: the professional is responsible for the accuracy of the test and must not alter results.

  • State regulations: comply with the state in which the test is conducted; some states have stricter requirements than the EPA protocols.